background image

 

Tripp Lite

1111 West 35th Street

Chicago, IL 60609 USA

Telephone: +(773) 869 1234

E-mail: 

[email protected]

Model #: SU1500RTXL2UA

SmartOnline 1.5kVA On-Line Double-Conversion UPS, 2U Rack/Tower, 100/110/120V NEMA outlets

 

Highlights

1500VA / 1.5kVA / 1200 watt on-line double-conversion 2U rack/tower UPS 

100/110/120V +/-2% output at 50/60Hz, high efficiency economy mode option

Expandable runtime, Hot-swap batteries; 19 in / 48.3cm installed depth

USB, RS232 & EPO ports; support for SNMP/WEB card options

Front panel status LEDs with detailed load and battery metering

2 independently switchable output load banks

NEMA 5-15P input; 5-15R outlets

Description

1500VA online, double-conversion UPS system for critical server, network and telecommunications equipment. 2U rackmount form factor with an

installed depth of only 19 inches. Expandable battery runtime with optional BP48V24-2U (limit 1) and BP48V60RT-3U (multi-pack compatible)

external battery packs. Full-time sine wave 100, 110 or 120V output with +/-2% voltage regulation. Online, double-conversion Uninterruptible Power

Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates

continuously without using battery power during brownouts to 65V and overvoltages to 150V. Highly efficient operation in optional economy mode

saves BTU heat output and energy costs. NEMA 5-15P input plug and NEMA 5-15R output receptacles. Network-grade AC surge and noise

suppression. Zero transfer time between AC and battery operation. Network management interfaces support simultaneous communications via USB

port, DB9 serial port and SNMPWEBCARD slot. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact closure

monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and

Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network

interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated two-bank PDU

switching supports load shedding and remote reboot of connected equipment. 3-stage metered current monitoring and battery charge status LEDs.

LED display panel easily rotates for viewing in rackmount or tower configurations. Dataline surge suppression for dialup, DSL or network Ethernet

connection. Utility power and voltage regulation LEDs. Audible alarm. Self-test. Fault-tolerant auto-bypass mode. 4-post rackmount accessories

included; 2-9USTAND tower kit and 2POSTRMKITWM 2-post rack & wallmount accessories available. Field-replaceable, hot-swappable internal

batteries and external battery packs. Attractive all-black color scheme. $250,000 

connected equipment insurance

;

Package Includes

SU1500RTXL2Ua Online Double-Conversion UPS System

PowerAlert Software and cabling

Mounting hardware for 4 post rack enclosures

Instruction manual 

Features

SmartOnline high-performance UPS system is ideal for critical voice, data, medical and industrial network applications

True on-line, double-conversion UPS provides perfectly regulated sine wave output within 2% of 100/110/120V (user selectable) under all

usage conditions

Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time

Summary of Contents for SmartOnline SU1500RTXL2Ua

Page 1: ...communications via USB port DB9 serial port and SNMPWEBCARD slot Built in DB9 port offers both enhanced RS 232 enabled monitoring data plus contact closure monitoring ability HID compliant USB interf...

Page 2: ...nagement and auto shutdown features of Windows and Mac OS X Included PowerAlert UPS monitoring software supports safe unattended shutdown monitoring and control via local connected servers plus any nu...

Page 3: ...put circuit breaker 20A UPS Input cord length ft 10 UPS Input cord length m 3 Recommended Electrical Service 15A 120V BATTERY Full load runtime minutes 5 min 1200w Half load runtime minutes 14 min 600...

Page 4: ...cancel operation Power fail alarm can be silenced using alarm cancel switch Switches 2 switches control off on power status and alarm cancel self test operation SURGE NOISE SUPPRESSION UPS AC suppress...

Page 5: ...4 Battery mode BTU hr full load 664 2 AC economy mode efficiency rating 100 load 94 COMMUNICATIONS Communications interface USB HID enabled DB9 Serial Contact closure EPO emergency power off Slot for...

Page 6: ...ibution PDUB15 Dual source Power Distribution Unit PDU with Manual Transfer Switch enables Hot swappable UPS Replacement in Critical Network Applications 1 Power Distribution PDUMH15AT Metered PDU wit...

Page 7: ...ation including related products owner s manuals and additional technical specifications can be found online at www tripplite com en products model cfm txtModelID 2949 Copyright 2012 Tripp Lite All ri...

Reviews: