background image

Tradedor TD55DM & TD55SEL Installation Guide

TD55DM & TD55SEL

Installation Guide

Summary of Contents for TD55DM

Page 1: ...Tradedor TD55DM TD55SEL Installation Guide TD55DM TD55SEL Installation Guide...

Page 2: ...Tradedor TD55DM TD55SEL Installation Guide 1 Installation Guide Finished door...

Page 3: ...vel Tape measure Power drill 10mm A F Spanner 2 x Pozi screwdrivers 7mm Metal drill bit 10mm Metal drill bit 7mm Masonry drill bit Hacksaw Small electrical screwdriver 4mm A F Allen key Tradedor Compo...

Page 4: ...g please remove any items of loose clothing to avoid any risk of entanglement or injury 4 Your door comes complete with a 3 pin plug as standard this is supplied and must be fitted with a 13amp fuse w...

Page 5: ...firmation and double check your opening size to make sure everything is correct fig 1 1 fig 1 2 2 Carefully remove your old garage door and frame if applicable 3 Sweep down the sides and lintel with a...

Page 6: ...s has the flat face when looking in the rear box section of the guide runner fig 2 1 It will fit against the wall for a behind fixing or face out of the garage for a between fixing 2 Measure from floo...

Page 7: ...loor to highest point deduct 210mm and cut guide runners to size Behind Lintel Fixing Cut guide runners to measured height LINTEL ROOF OR JOISTS GUIDE RUNNER GUIDE RUNNER GUIDE RUNNER TOP ROLL TOP ROL...

Page 8: ...remembering to check the guide runners are square and plumb after each fixing 7 Check to make sure all fixings have not caused the front fascia to be pulled in as this will rub against the slats caus...

Page 9: ...Tradedor TD55DM TD55SEL Installation Guide Finished door from inside 8...

Page 10: ...the screw to hold in place and make sure it is level and square while you mark the remaining two fixings located at the bottom of the receiver box 4 Remove receiver box from wall and drill 5mm holes...

Page 11: ...switches fig 5 2 flick the second from top dip switch to the right You should now have to press and hold the down button for the door to close 1 Slide the black cover down on the remote control hands...

Page 12: ...ree Switching Conn N Connectio provide a free swit operation Com Close Open External Key switch Connection This is a special connection does not provide a voltage o The unit must be factory mo to give...

Page 13: ...oses press the stop button and flick the middle dip switch up fig 6 2 B You should now have to press and hold the down button for the door to close Deleting Remote Control Handset s Memory 1 Press and...

Page 14: ...m down from the roof ceiling is recommended Drill and then secure in place fig 8 4 4 Hook the top of the receiver box on to the wall fixing plate with the cable glands pointing downwards and secure wi...

Page 15: ...upwards direction Should the barrel be turning in the down direction swap motor wires black to U and brown to V 2 Press and hold the top open button on the receiver board to check fig 8 5 fig 8 4 7 B...

Page 16: ...Mounting The Rollixo Rts Remove the courtesy light cover 1 2 Unscrew and remove the panel cover 3 Mark the wall drilling positions 4 Secure the Rollixo RTS in place Motor Wiring L1 N2 L M 12 34 Bleu M...

Page 17: ...tically downwards 1 Screw the bulb supplied into the light fitting 2 Refit the panel cover and secure with the screw 3 Refit the courtesy light cover 4 All the LED s come on briefly and then out If th...

Page 18: ...f the floor and turn again 15 times in the negative direction take the door back down and repeat until the door does stop before it reaches the floor 7 Whilst holding the down button turn the wand in...

Page 19: ...Tradedor TD55DM TD55SEL Installation Guide fig 9 1 fig 9 2 fig 9 3 18...

Page 20: ...e to the left This will give access to the board fig 10 2 3 Remove the plastic tab from the batteries and the LEDs will blink on the safety edge unit 4 Inside the receiver box press and hold the PROG...

Page 21: ...s before restarting the whole procedure refer to page 24 to clear memory 1 The curtain must be all the way down in the closed position before starting 2 Press and hold the PROG button on the receiver...

Page 22: ...itches are down in the base rail unit fig 11 8A these are just off centre at the top of the unit usually blue or red 5 Set the sensitivity on the small dial fig 11 8B to 3 to start This can be adjuste...

Page 23: ...d hold the PROG button on the receiver box main board for 2 seconds until the red LED lights up and stays on fig 11 10 This can be found in the bottom right next to the dipswitches 3 Press START butto...

Page 24: ...luminate 5 Press bottom button on handset fig 12 2B The panel will beep to confirm it has accepted Repeat for all other handsets 6 Leave for several seconds and the receiver box will beep twice to con...

Page 25: ...To clear memory you will need a small screwdriver fig 12 3 MR 1 Press and hold the PROG button fig 12 4A on the receiver card this is the card plugged onto the board until you hear a single beep 2 Ins...

Page 26: ...Prog button on the unit until the Rollixo panel Prog LED flashes then let go this could be up to 5 seconds the 2 units are now active 2 Check the operation of the door by pressing the Rollixo Up Down...

Page 27: ...Safety Edge Bring the door down to its final closed end limit position If the door lands on floor and stops go to point If the door comes to floor and retracts bounces back then see check the detail b...

Page 28: ...The LED will come on go out start to flash rapidly then let go of the Prog button The LED will flash slower then go out The safety edge transmitter has been deleted Approximately 14 seconds Prog Prog...

Page 29: ...s close to the winding stem and gland as possible hook the back case into the top lip where the two cases meet fig 13 5 and slide across to go all the way to the edge of the header plate making sure w...

Page 30: ...tch fig 14 4 Right Block 13 Up wire Left Block 14 Down wire Right Block 14 Common wire for the supply to the switch Left Block 13 Right Block 14 Link wire between terminals To open key switch remove s...

Page 31: ...Block 13 Up wire Left Block 14 Down wire Right Block 14 Common wire for the supply to the switch Left Block 13 Right Block 14 Link wire between terminals To open key switch remove screw then turn key...

Page 32: ...econds then go out This means it has been programmed If you wish for more than 1 access code then it must be programmed to a separate channel otherwise it will just replace the already stored code Acc...

Page 33: ...ided 2 Press the RESET button 3 Check that the Digipad has been commissioned by pressing on one of the keypad buttons If the lower indicator light comes on the Digipad has been commissioned If it does...

Page 34: ...6 7 8 9 10 11 12 13 16 17 18 19 20 22 14 15 aerial 24 vdc terminal type of terminal Connection Comments 1 Earth RDO CSI 50 or 60 motor 2 L1 3 Neutral 4 L2 5 Contact Fall protection NC contact 6 Share...

Page 35: ...emove from the wall drill 4 fixings outside and cut plastic tube to size then reinsert in wall 5 Insert universal joint at bottom of shaft into the plastic tube end and mark 2 fixing holes 6 Mark the...

Page 36: ...he security straps if these are disconnected or broken you will need to contact the office to purchase some more 4 Can you open the door by using the manual winding handle If so then try the buttons o...

Page 37: ...by using the winding handle If so then try the buttons on the box inside the garage after winding if the door still will not work then you will need to contact the office as the safety brake on your...

Page 38: ...Tradedor TD55DM TD55SEL Installation Guide Notes...

Page 39: ...Tradedor TD55DM TD55SEL Installation Guide Notes...

Page 40: ...2019 All Rights Reserved Tradedor is a trading name of Rollerdor Ltd Registration Number 10676267 VAT Number 990994847 Tradedor 16 Jarrold Way Bowthorpe Employment Area Norwich Norfolk NR5 9JD 44 0 1...

Reviews: