Summary of Contents for Dynasafe HF 32

Page 1: ...c o I J I J z dynasafe HF 32 universal load cell I It I equipment in accordance with CE directives 0420001103 03 96 o operating and maintenance manual racI8 ...

Page 2: ...llation and operation of Dynasafe equipment should only be carried out in accordance with the appropriate health and safety at work regulations 4 Never apply to the Dynasafe a load or an effort in excess of the working load limit and never use it for an operation for which it is not intended 5 TRACTEL SA declines any responsibility for the consequences of dismantling or altering the machine by any...

Page 3: ...the load cell on the wire rope near the dead end fixed point The connecting cable should be uppermost Replace the tightening bracket K ensuring that it is correctly positioned depending on the diameter of the wire rope See page 4 and 5 Adjust the tightening screws J symetrically 0 5 kgm to ensure that there is no risk of movingthe load cell out of line with the wire rope Excessivetightening may br...

Page 4: ...e rope from 9 mm to 13 mm diameter and for loads from 450 kg to 2000 kg L _ _ _ Forwire ropefrom 14 mmto 16 mm diameter and for loads from 650 kg to 2800 kg Correct positioning of the tightening bracket depending on the diameter of the wire rope 5 mm to 8 mm wire rope withoutthe rubbercompression pad M6 screws X 25 mm supplied Fig 3 M6 screw x 25 mm X2 9 mm to 16 mm wire rope with the rubber compr...

Page 5: ... mm diameter and for loads ranging from 500 kg to 4000 kg with the rubber compression pad For wire rope from 23 mm to 26 mm and for loads ranging from 800 kg to 6000 kg with the rubber compression pad Correct positioning of the tightening bracket depending on the diameter of the wire rope 17 mm wire rope withoutthe rubbercompression pad M8 screws X 40 mm supplied Fig 3 18 mm to 26 mm wire rope wit...

Page 6: ... An additional load equivalent to 10 of Pm ACTION EXPLANATION 1 Lift the two loads 100 10 of Pm The additional 10 load represents the overload value permitted under the European directives 2 by 10 cm To adjust the safety trip point If an overload situation is detected in thewire rope without lifting the loads the preadjustment of the load cell in the factory is too low for your lifting system Solu...