background image

                                                                                                                       

 

Dual Swing Gate Opener 

User’s Manual 

Model: 

 

 

 

 

 

 

 

 

 

TOPENS Website 

www.topens.com 

Email: [email protected] 

 

 

 

VER 21a

C030569 

Please  read  and  follow  all  warnings,  precautions  and  instructions  before 
installation and use. 

Coming  with  UPS01  uninterrupted  power  supply,  this  series  gate  opener  can  be 
powered by AC 100-240V electricity directly. It is allowed to use additional battery 
(NOT incl.) and solar panel (optional) as BACK-UP or MAIN power source with this 
UPS01.     

Never connect the solar panel to the control board directly to charge the battery. 

Periodic checks of the opener are required to ensure safe operation. 

Save this manual. 

A3132 / A5132 / A8132 

A3132S / A5132S / A8132S 

Summary of Contents for A3132

Page 1: ...interrupted power supply this series gate opener can be powered by AC 100 240V electricity directly It is allowed to use additional battery NOT incl and solar panel optional as BACK UP or MAIN power s...

Page 2: ...n ca Amazon co uk Amazon de Other Please Specify Order Product Model Purchase Date Full Name Phone Email Address VERY IMPORTANT Street Address Apartment Unit City State Province Zip Code Country Regio...

Page 3: ...6 Installation Overview 8 Preparation for Installation 8 Install the Opener on the Gate for Pull to Open 9 Install the Opener on the Gate for Push to Open 13 Mounting of the Control Box 18 Connection...

Page 4: ...destrian access shall be located such that persons will not come in contact with the moving vehicular gate 8 Pedestrians should never cross the pathway of a moving gate The gate opener is not acceptab...

Page 5: ...lay on or around the gate and keep all controls out of their reach NOTE TOPENS Gate Operator can be used for driveway gates made by steel wood vinyl and shaped as panel tube and chain link While use o...

Page 6: ...3 A3132 Parts List...

Page 7: ...4 A5132 A8132 Parts List...

Page 8: ...Control ERM12 External Receiver TC186 R WiFi Smartphone Remote Control with Camera TC186 WiFi Smartphone Remote Control with Camera TKP3 Wireless Keypad TC175P Wired Keypad TEW3 Vehicle Sensor Exit Wa...

Page 9: ...Kit Tools Needed Power Drill Tape Measure Open End Wrenches 14 17 or Adjustable Wrenches Wire Strippers C Clamps small medium and large Level Hacksaw or Heavy Duty Bolt Cutters Phillips Screwdriver Te...

Page 10: ...Reverse in case of obstruction during gate closing Built in adjustable auto close 3 120 seconds Built in max Motor running time MRT for multiple safety protection 40 seconds Reliable electromagnetism...

Page 11: ...the Post Brackets are curved When mounting the Post Brackets use bolts long enough to pass through the entire post M10 x 200 bolts are included Concrete anchors are not provided When mounting the Pos...

Page 12: ...e Post Bracket The tables show the maximum opening angle of the gate for a given A and B For example if A is 16cm and B is 14cm the maximum opening angle of the gate is 110 Pull to Open Installation G...

Page 13: ...se This releases the motor and allows the push pull rod to be manually extended and retracted To restore normal operation turn the key 90 counterclockwise 4 With the opener fully retracted and with th...

Page 14: ...st 2 5cm of clearance or if the opener and the Post Pivot Bracket are binding rotate the Post Pivot Bracket and or move the Post Bracket Assy to obtain the minimum clearance and eliminate the binding...

Page 15: ...nut 9 Attach the gate brackets to each gate by inserting two M10 x 75 bolts through the gate brackets and the drilled holes in the gates Fasten each bolt with one 10 lock washer and one 10 nut 10 Cut...

Page 16: ...stallation Install the Opener on the Gate for Push to Open The position of Post Bracket is very important The following illustrations and tables are required to determine the proper mounting position...

Page 17: ...on the top of the gate opener insert the release key and turn the key 90 clockwise This releases the motor and allows the push pull rod to be manually extended and retracted To restore normal operati...

Page 18: ...at the opener and the PSO part are not binding in both the gate open and gate closed positions If there is not at least 2 5cm of clearance or if the opener and the PSO part are binding rotate the PSO...

Page 19: ...10 5 mm diameter holes through the post and the gate at the marked locations 8 Attach the post bracket assemblies to the gate posts by inserting M10 x 200 bolts through each post bracket assy and the...

Page 20: ...the opener fully retracted and with the gate in the fully closed position for Push to Open installation insert a clevis pin through the gate opener and the PSO part and insert another clevis pin throu...

Page 21: ...Mounting of the Control Box Use 4 deck screws not provided to install the control box Even though the control box is waterproof designed for safety reason and a longer service life it is recommended t...

Page 22: ...than 12 AH is required NOT INCLUDED 2 PCS 12VDC batteries can be connected in series to become 24VDC to power up the gate opener The following diagram will show you how to connect 2 PCS batteries in...

Page 23: ...er source only use the solar panel to charge the batteries If the AC electricity is not available then you can choose the batteries as the power source and use the solar panel to charge the batteries...

Page 24: ...electricity and back up batteries use the AC electricity and the solar panel to charge the batteries at the same time If you want to use the solar panel and the AC electricity to charge the batteries...

Page 25: ...rminal 15 the black wire into MOTOR1 terminal 16 the blue wire into ULMT1 terminal 17 the green wire into COM terminal 18 and the yellow wire into DLMT1 terminal 19 2 Actuator 2 Slave gate close first...

Page 26: ...o connect the electric lock to the control board The 2 wires of J1 of lock plus should be wired to the 13 and 14 terminal of the control board No matter the polarity Red wire of J2 should be wired to...

Page 27: ...rchase additional remote controls the gate opener must be programmed to accept the new remote code If you lose one of any remote control please erase and reprogram all other remote controls to have a...

Page 28: ...press OK button on keypad and CODE LED will flash for 3 seconds and then be OFF which indicates the keypad has been programmed successfully You can use the default password 888888 to operate the open...

Page 29: ...desired open position press the remote control to stop the opener Use a screwdriver to loosen the screw of the limit B slightly slide the limit switch B inwards If the arm opens halfway and fails to...

Page 30: ...ON Open interval is enabled OFF Open interval is disabled Factory default setting is ON NOTE Open interval time can be adjusted by the OPEN DELAY potentiometer DIP Switch 4 Enable disable close interv...

Page 31: ...Turn the potentiometer clockwise to increase the stall force and turn it counter clockwise to decrease the stall force Maintenance Warning Disconnect power before servicing 1 Using a clean dry cloth...

Page 32: ...ries have been connected to the UPS01 well 3 Battery is over discharge if you only use batteries with the UPS01 to power up the gate opener The voltage of the battery should above 22V to make the gate...

Page 33: ...usted too small Turn the Potentiometer E to increase the force 3 Ensure the photo beam is not blocked when a photocell is used Both of the gates do not move when operating Flash quickly for 3 seconds...

Page 34: ...check what will happen to the 2 arms If the faulty arm is still faulty then the arm itself is faulty If the failure changes to the other arm which worked normally before then the control board is fau...

Page 35: ...you have any need to contact us the info below will help you get in touch TOPENS Website www topens com Contact Us E mail support topens com Kindly include your Product Model Purchasing Date Site Ord...

Reviews: