TITAN

 

Stainless Steel Globe Lantern

 

 

             

 

 

Stainless Steel Housing 

 

Glass Diffuser 

 

Wall Box Cover

 

 

PIR (Motion Sensor) 

 

LED Comfort Light 

 

INTRODUCTION

 

 

The  Titan  Stainless  Steel  Globe  Lantern  is  designed 
for use outdoors. 

 

The unit offers you an LED Comfort Light facility that is 
always on during the hours of darkness. 

 

Also during the hours of darkness, the built-in passive 
infrared  (PIR)  sensor  turns  on  the  main  Globe  Light 
lamp  when  the  PIR  sensor  detects  a  moving  heat 
source in its coverage area. During daylight the built-in 
photocell  saves  energy  by  deactivating  the  LED 
Comfort Light and the main Globe Light lamp. 

 

Note:  Read  this  entire  manual  before  you  start  to 
install the system. 

 

SAFETY PRECAUTIONS 

 

 

DO NOT install when it is raining.

 

 

Isolate the power supply before installation. 

 

UK Building Regulations require outdoor mains 
installations be carried out by a qualified 
electrician. 

 

BS7671: 2008 IEE Wiring Regulations must be 
complied with in all respects. 

 

HO5RNF round flexible cable and drip loops must 
be used to avoid water ingress damage to the 
unit. 

 

Ensure that the power supply is protected by a 6A 
circuit breaker or suitable fuse. 

 

Ensure minimum distance of 2.5m from objects in 
front of the unit. 

 

The unit must be installed vertically (FIGURE 1a) 
NOT at an angle (FIGURE 1b). 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

 

                  FIGURE 1a                        FIGURE 1b 

 

CHOOSING A MOUNTING LOCATION

 

 

 

For  the  best  results,  mount  the  Globe  Light  onto 
normal brickwork 1.8~2.5m above the ground. 

 

Avoid  aiming  the  PIR  sensor  at  pools,  heating 
vents, air conditioners or objects that may change 
temperature. 

 

Avoid  pointing  the  PIR  sensor  at  trees  or  shrubs 
or where the movement of pets or animals may be 
detected. 

 

Avoid  locations  where  direct  sunlight  will  shine 
onto the front of the PIR sensor for long periods, 
deterioration  of  the  Fresnel  lens  may  occur 
leading to poor triggering response. 

 

Prior  to  mounting,  keep  in  mind  that  the  PIR 
sensor is more sensitive to a heat source moving 
across  its  coverage  area  and  less  sensitive  to  a 
heat  source  that  moves  directly  towards  the  PIR 
sensor (FIGURE 2). 

 

FIGURE 2 

 

INSTALLATION 

 

 

For  the  best  results,  mount  the  Globe  Light  onto 
normal brickwork 1.8~2.5m above the ground. 

 

Unscrew the two nuts on the front plate of the unit. 

 

Position the mounting plate on the wall and mark 
the holes before drilling. 

 

There  is  an  Up  arrow  on  the  mounting  plate 
ensure this is pointing Up when marking the holes 
for drilling. FIGURE 3 

 

 
 
 
 
 
 
 
 
 

 

 

 

 

FIGURE 3 

 

 

 

 

 

 

 

 

Up   