background image

Ins
tallation & Oper

ating Ins

tructions

Surface Mount  

IR DALI Presence Detectors

Model: PDSMDALI Surface Mount  

IR DALI Presence Detector

Model: PDSMCDALI Surface Mount  

IR DALI Corridor Presence Detector

Summary of Contents for PDFMCDALI

Page 1: ...l a t i o n O p e r a t i n g I n s t r u c t i o n s Surface Mount IR DALI Presence Detectors Model PDSMDALI Surface Mount IR DALI Presence Detector Model PDSMCDALI Surface Mount IR DALI Corridor Presence Detector ...

Page 2: ...r maintenance ensure the mains supply to the PIR sensor is switched off and the circuit supply fuses are removed or the circuit breaker turned off It is recommended that a qualified electrician is consulted or employed for the installation of this PIR sensor and that it is installed in accordance with the current IEE wiring and Building Regulations ...

Page 3: ...djustment OFF 1m 2m 5m 15m 30m ON Warm up period 60 seconds DALI Group Select channel 0 to E for grouping 0 to 14 to the connected load Channel F Broadcast to all the connected load Operating Temperature 20 C to 40 C IP20 rated suitable for restricted internal applications CE compliant PDSMDALI Motion detection range Up to a 9m diameter approx at a 2 5m mounting height Dimensions W x H x D 140 x 1...

Page 4: ...nt directly TOWARDS it Therefore position the unit so that the sensor looks ACROSS the likely approach path Reflective surfaces i e white painted walls may cause false activation under extreme conditions Avoid positioning the sensor where there are any sources of heat in the detection area extractor fans tumble dryer exhausts etc including opposite any other light sources Install the sensor at lea...

Page 5: ...ing holes taking care to avoid any joists electrical cables or water gas pipes that may be hidden beneath the surface Insert the rawl plugs into the holes 5 6 Pass the 230V 50Hz mains supply and load cable through the cable entry point on the foam gasket and then the back plate ensuring the grommet is used to maintain the IP rating of the PIR sensor 5 7 Secure the foam gasket and back plate to the...

Page 6: ...5 230V 50Hz Mains Supply Live Supply Brown or Red to L Neutral Supply Blue or Black to N 6 Connection Diagram Connections are as follows ...

Page 7: ...ay for when the sensor is activated STDBY Standby TIME Used to select the time delay for standby fixed at 20 of the brightness of the load DALI Group Used to select the channel 0 to E for grouping 0 14 of the connected load or Channel F to broadcast to all of the connected loads Push Button Function S Terminal An external push button can be installed for manual light control see section 6 Connecti...

Page 8: ...remote control the sensor LED indicator and load will turn ON for 3 seconds when each movement is detected Without the IRRDALI remote control the sensor LED indicator will turn on the load for the duration as set on the TIME setting minimum is 10 seconds Walk around the sensor to establish the detection area Turn the TIME and LUX control settings to the desired positions The detector is now in Aut...

Page 9: ...tally or vertically until the desired area of detection is obtained For your information the centre section of the lens mask covers short range detection and the outer edge of the lens mask covers long range Push the lens mask into the slot around the sensor head The position can be adjusted by sliding it around the slot as follows PDFMCDALI PDFMDALI ...

Page 10: ...is operational Load goes ON and OFF too quickly Ensure light and heat are not being deflected onto the detector Check for white or reflective surfaces that may be causing the problem Note the detector is more sensitive in cold weather Make sure the sensor isn t installed close to an air conditioner Load stays ON Check the wiring to ensure the load isn t wired directly to the supply Adjust the time...

Page 11: ...h proof of purchase and it will be replaced free of charge For years 2 and 3 or any difficulty in the first year telephone the helpline on 020 8450 0515 Note A proof of purchase is required in all cases For all eligible replacements where agreed by Timeguard the customer is responsible for all shipping postage charges outside of the UK All shipping costs are to be paid in advance before a replacem...

Page 12: ...l csc timeguard com For a product brochure please contact If you experience problems do not immediately return the unit to the store Telephone the Timeguard Customer Helpline Qualified Customer Support Coordinators will be online to assist in resolving your query HELPLINE 020 8450 0515 or email helpline timeguard com www timeguard com ...