background image

TIF3110

Psychrometer
with IR Thermometer

  Three instruments-in-one:

  •  Psychrometer function measures ambient 

   temperature and humidity, dew point,

   and wet bulb.

  •  IR thermometer measures surface 

   temperature without contact.
  •  Input for any style of K-type thermocouple.

  Large, backlit LCD display allows the user to 

view the IR or thermocouple input, %RH, and 

ambient temp, Wb, or DP simultaneously.

  Red laser indicator included with IR function.

  Auto-range selection.

  Low battery indicator.

  Auto shutdown.

FUNCTIONS

  1.  Laser pointer for IR function.
  2.  Input jack for K-type thermocouple.
  3.  Temperature and humidity sensor.
  4.  LCD display.
  5.  Hold button for temp and humidity function.
  6.  Select from air temp, wet bulb, or dew point 

    readings.
  7.  Hold button for IR or thermocouple input.
  8.  LCD backlight.
  9.  Power ON/OFF.
 10.  MAX/MIN selection for IR or thermocouple 

    input.
 11.  Select between °C and °F.
 12.  IR measurement trigger.
 13.  MAX/MIN selection for temp and humidity.

© 2008 SPX 

Sheet 1 of 

2

FEATURES

1

2

3

4

5

6

7

8

9

10

11

12

13

Summary of Contents for TIF3110

Page 1: ...icator included with IR function Auto range selection Low battery indicator Auto shutdown FUNCTIONS 1 Laser pointer for IR function 2 Input jack for K type thermocouple 3 Temperature and humidity sensor 4 LCD display 5 Hold button for temp and humidity function 6 Select from air temp wet bulb or dew point readings 7 Hold button for IR or thermocouple input 8 LCD backlight 9 Power ON OFF 10 MAX MIN...

Page 2: ...1 RH 3 Wet 6 88 140 F 0 1 F C Bulb 21 6 60 C Dew 90 4 140 F 0 1 F C Point 68 60 C SPECIFICATIONS Back sheet 1 of 2008 DISTANCE D TO SPOT SIZE S As the distance D from the object increases the spot size S of the area measured by the unit becomes larger The relationship between distance and spot size is listed on the diagram above The focal point is 914mm 36 The spot sizes indicate 90 encircled ener...

Page 3: ...era tion mode from air temperature either wet bulb or dew point TEMP WET BULB DEW POINT and RH HOLD 1 Press the HOLD button to freeze air humidity and temperature reading in the upper half of the display The HOLD icon will appear in the upper right corner of the display 2 Press the HOLD button again to return to nor mal operation and HOLD icon will disappear INFRARED THERMOMETER CAUTION To prevent...

Page 4: ...left corner of the display the unit s battery is low Follow the directions in the Main tenance section to replace the battery MAINTENANCE REPLACING THE BATTERY 1 The thermometer must be OFF when changing the battery Press to power OFF the thermometer 2 On the back side of the thermometer locate the symbol 3 While holding the thermometer place your thumb on the With gentle pres sure push downward a...

Reviews: