background image

80 PLUS Verification and Testing Report

TYPICAL EFFICIENCY (50% Load):
AVERAGE EFFICIENCY :
80 PLUS COMPLIANT:

YES

Value

Units

100-240 Volts

15

Amps

47-63

Hz

1200

Watts

Note: All measurements were taken with input voltage at 115 V nominal and 60 Hz.

Input AC Current Waveform (ITHD = 5.53%, 50% Load)

I

RMS

PF

A

-12V

3.3V

5V*

5VSB

2.56

0.99

9.2%

20%

Light

291

11.9/0.1

3.3/4.9

5/4.9

5/0.6

241

82.97%

6.07

1.00

5.5%

50%

Typical 

696

12/0.3

3.2/12.2

5/12.2

4.9/1.4

597

85.77%

12.37

1.00

3.4%

100%

Full

1421

12.2/0.7

3.1/24.3

4.8/24.5

4.7/2.9

1172

82.46%

Tested by Electric Power Research Institute, Knoxville, TN.

5/19/2008

Efficiency 

%

Rated Output Power

Load 

(%)

Rated Specifications

Input Voltage
Input Current

I

THD

 (%)

Input 
Watts

Fraction 
of Load

DC Terminal Voltage (V)/ DC Load Current (A)

Output 

Watts

12V (cumulative of 12V1, 12V2, etc.)

12/16.3
12/40.7

11.8/81.3

Test Date 

Input Frequency

667

Type

Ecos ID #

Model Number
Serial Number
Year

ATX12V & EPS12V

NA
2008

Manufacturer

85.77%
83.73%

THERMALTAKE
W0156 Toughpower 1200 AP

Input and Output Power

Input Watts

Output Watts

0

200

400

600

800

1000

1200

1400

1600

20%

50%

100%

Loading (% of Rated Output Power)

P

o

w

e

r (W

atts)

Efficiency of the Power Supply

30%

40%

50%

60%

70%

80%

90%

0%

25%

50%

75%

100%

125%

Loading (% of Rated Output Power)

E

fficien

cy (%

)

Efficiency %

These tests were conducted as a part of the 80 PLUS program.  80 PLUS is 
a computer buy-down program to promote high-efficiency power supplies 
(greater than 80% efficiency in the active mode) in desktop computers and 
desktop-derived servers.

Input Current and Voltage Waveforms

-200

-150

-100

-50

0

50

100

150

200

0

0.003

0.006

0.009

0.012

0.015

Time (s)

V

o

lt

age (V

)

-20

-15

-10

-5

0

5

10

15

20

C

u

rrent (A

)

Voltage 

Current 