ALL IN ONE

Heat Pump Water Heater

INSTALLATION AND OPERATION INSTRUCTIONS

Please read this user’s manual carefully before operate the unit.

Summary of Contents for RS-3.6FAD/260LX9

Page 1: ...ALL IN ONE Heat Pump Water Heater INSTALLATION AND OPERATION INSTRUCTIONS Please read this user s manual carefully before operate the unit...

Page 2: ...t the unit is STOP operation when disconnecting the power supply to the unit Disconnect all electric power supplies before servicing 3 This appliance is not intended for use by persons including child...

Page 3: ...heat pump it may cause the dangerous to people or damage the system 9 To make the system more efficiency please install the main unit at a place with good ventilation 10 Do not put or install the ope...

Page 4: ...2 B Description of heat pump Unit constructions outside...

Page 5: ...Electric Heater hole is only for the unit with Auxiliary heater models other models without auxiliary heater function are not available 3 There are two Circulation Water Hole for optional connection...

Page 6: ...ction 3 If install as Fig 2 the unit can be installed by the middle of the wall and connect the air inlet and outlet pipe for air exchange The distance of the unit and wall or other obstacle should no...

Page 7: ...pe The safety valve should be connected by a small rubber pipe interlinked with atmosphere this pipe must not be blocked in order to drain the water when the tank s pressure exceeds 0 7MPa 14 Water in...

Page 8: ...de by themselves 3 Before installation it s better to reserve a water supply pipe interface hot water outlet pipe interface and drainage pipe interface Among them the water supply pipe and hot water o...

Page 9: ...7 D Operation panel instruction 1 Panel Operation...

Page 10: ...8 D Operation panel instruction 2 Panel Display Cloud icon flashing during the connect with the internet always lighting after connected with the internet no lighting means no cloud control function...

Page 11: ...temp amendment 5 5 0 C Compressor F21 Compressor start delay 0 10 3 minute F28 Econ mode turn on or off electric heater 0 1 1 F29 Heat pumps working or not in heater mode 0 1 1 Defrost F31 Defrost sta...

Page 12: ...ctronic expansion valve EEV F70 EEV opening query 0 480 F71 EEV control mode 0 2 0 F72 Manually set EEV opening 100 480 350 F73 Set EEV superheat degree 15 15 5 F74 Set EEV discharge temp 85 110 92 F7...

Page 13: ...r temp is too high 2 Change the Electric heater A7 Exhaust temperature too high 1 Lack of refrigerant 2 Mix with air in system 3 Lack of lubricating oil 1 Supply refrigerant 2 Re vacuumizing and fill...

Page 14: ...ration for a long time there may have condensation water hereabout the air outlet or pipe especial in humidity weather this is a normal phenomenon use a dry washcloth to clean it or by air dry 6 The a...

Page 15: ...ation panel back panel and top cover of the unit follow the below steps Fig 5 6 to process Fig 5 Fig 6 Top cover disassemble Remove all the item 2 screws of the top cover 1 push up the top cover verti...

Page 16: ...ig 7 Fig 8 2 Loose the power wire from the terminal block to avoid the wire get stuck when move up the top shell 3 Remove all the screws item 2 from the Back panel item 5 two sides decoration bar item...

Page 17: ...ump without auxiliary electric heater 2 1 Comp Fan Valve Elect R S C BLACK 12V RED 220V 5 COMPRESSOR LOW HI BXS N LOW PRESURE PROTECTOR HI PRESURE PROTECTOR RETURN GAS TEMP SENSOR EXHAUST TEMP SENSOR...

Page 18: ...OWER SUPPLY YELLOW GREEN Transformer WATER TEMP SENSOR OPERATION PANEL ELECTRIC HEATER YELLOW GREEN 4 WAY VALVE FAN MOTOR YELLOW GREEN ELECTRIC HEATER PROTECTOR PRESURE PROTECTOR Electronic expansion...

Page 19: ...17 G Annex list ITEM NAME SPECIFICATION QUANTITY REMARK 1 Safety valve 1 2 Manual 1...