Summary of Contents for RX 800

Page 1: ...RX800 OWNERS MANUAL SOURCE INPUTS 4 5 LINK LINK RX800 6 SOURCE 4 Z0NE Audio Distribution Amplifier 2 x Streamer Inside ...

Page 2: ...2 ...

Page 3: ...e can use IR controller or keypads to enjoy the powerful audio High functionality and performance bring you musical enjoyment just the way you want it INTRODUCTION FEATURE Each zone provides 50Wx2 4 Ohm output power High efficiency more than 85 Class D amplification 6 Line input sources including 2 Audio Streamers Input 4 5 USB ports for playing music files from USB Flash Drive Input 4 5 Each zone...

Page 4: ...work Dimension Weight 25W x 2 per zone at 8Ω 50W x 2 per zone at 4Ω 100W per zone Bridged at 8Ω 85dB A WTD 0 1 20Hz 20KHz 47 K Ohm 250 mV Overload Short Circuit DC 12V DC 12V AC115V 60Hz 230V 50Hz 4P Terminal Block Input 1 2 RCA Jacks Input 3 3 5mm Jack S PDIF Input 4 5 Streamers or USB ports Input 6 RJ 45 For connecting with MAP KBT1 MAP KSP1 MAP KWS1 24Bit 48KHz MP3 WMA AAC AAC ALAC FLAC APE WAV...

Page 5: ...O BRIDGE SWITCH 4 SOURCE INPUTS 6 Stereo Analog Digital inputs Two Streamers are input 4 and 5 5 Input 1 PA Paging capability for Input 1 to broadcast to all zones when 12VDC is applied to the PA IN jack 6 STATUS When the zone is activated the corresponding jack will output 12VDC to trigger other device 7 IR EMITTERS IR Outputs 4 routed 1 common 8 PA IN 12VDC paging trigger input 9 EXT MUTE CONTRO...

Page 6: ...et 12 ETHERNET RS232 SWITCH ETHERNET When the amplifier connects to Ethernet RS232 When the amplifier control by PC or Control Device via RS 232 13 AGC Automatic Gain Control brings low level up to a present level 14 MASTER SLAVE SWITCH Set the unit ID when connecting multi Controller systems 15 KEYPAD RJ 45 jack Connects to the keypad hub for 4 keypads 16 VOLTAGE SELECT Please set to correctly in...

Page 7: ...7 1 7 2 5 6 3 4 3 ...

Page 8: ...8 RX 800 RX 800 RCA 3 5mm Stereo ...

Page 9: ...4 8 Ohm There are two modes that can be set for different setups Stereo or Bridge An 8 Ohm speaker can only be used when in Bridge mode To choose between modes use the mode switch to determine modes for each zone Number 2 Panel Descriptions page 5 9 and network STEREO MODE BRIDGE MODE ...

Page 10: ... specific zone as well as IR routing to the appropriate source devices once selected The MAP 800US also comes with a hub that allows for all 6 keypads to be connected to the amp via Cat5e 6 10 ZONE 1 ON ON OFF 1 2 3 ZONE 2 ON ON OFF 1 2 3 ZONE 3 ON OFF OFF 1 2 3 ZONE 4 ON ON OFF 1 2 3 ...

Page 11: ...11 RX 800 FRONT BACK reserved for cascading units 12VDC out to trigger external amplifier four four ...

Page 12: ...12 four 4 ...

Page 13: ...uting ONLY the Source that is selected on each zone can be controlled This prevents other sources from accidently be controlled when selected on other zones The RX 800 can allow 6 sources to be distributed to up to 12 zones on 3 different units using the provided ribbon cable to connect between units To do this first each unit needs to be addressed according using the MASTER SLAVE switch There are...

Page 14: ...4 In this mode only connect all sources to the MASTER unit and share these sources to Slav 1 and Slave 2 units And the original source inputs on Slav 1 and Slave 2 will be disabled Master SLAVE 1 SLAVE 2 ...

Page 15: ...AN1 port on the rear panel of controller to the local Wi Fi Router The Ethernet connection mainly for Wi Fi control via APP or other control devices 2 Connect the LAN2 port on the rear panel of control to the smart TV or other Network devices The port simply works as SWITCH function as long as the LAN1 port enabled to Ethernet Note When controlling via ETHERNET please make sure the ETHERNET RS232 ...

Page 16: ...SOURCE INPUTS 4 5 LINK LINK CONNECTION DIAGRAM 12V Trigger output MAP 800HD Network TV Router APP DVD Stereo Amplifier or Powered Subwoofer 16 ...

Page 17: ...er will connect with the local network automatically In case having the problem for connecting to the network please check the position of switches on the rear panel INTEGRATED NETWORK 1 Open the IE web browser of PC log in to the WEB configuration page of local Router to find the IP address of RX 800 shown as below Please switch to MASTER and ETHERNET Note Please do not press Reset button Note Pl...

Page 18: ...address Please visit www advanced ip scanner com for free download Then enter the IP address of RX 800 to the IE browser shown as below ensure the Serial Configure is 9600 n 8 1 After finishing this step RX 800 could be controlled through the local Network ...

Page 19: ...Download free software PuTTY Tool from the internet to control the device Operation diagram as below FOR CONTROLLING VIA OTHER SOFTWARE 19 ...

Page 20: ...RX 800 and port 8080 Click Open When the IP address connected the operation diagram shows as below Key in the command code to control RX 800 For the detail of command codes please find the RS 232 command codes in this instruction manual 20 ...

Page 21: ...cation with third party automation systems All keypad and remote control operations can be controlled via RS 232 in addition to system expands another 2 units linked together using the included 18 pin expan sion cable Using free software PuTTY Tool to control the device Operation diagram as below Note Set the switch to RS232 position Baud Rate 9600 8 N 1 DB9 Connector Pin out Tx Rx GND 21 ...

Page 22: ... Baud rate 9600 Click Open When the IP address connected the operation diagram shows as below Key in the command code to control RX 800 Note To find the information for the COM port please open the device manager of the computer shown as below 22 ...

Page 23: ...Rx GND CR Carriage Return 0x0D No case capitalization lowercase Control order structure xxPPuu CR Reply control order frame For xxPPuu CR xx stands for control object code 10 All Zones of Main unit 1 20 All Zones of Main unit 2 30 All Zones of Main unit 3 11 Zone1 of Main unit 1 12 Zone2 of Main unit 1 13 Zone3 of Main unit 1 PP Stands for control action code PR Power control PR00 Power off PR01 P...

Page 24: ...ol BL Balance control BL 00 20 Balance control CH Source Channel control CH 01 06 Source control Inquiry command structure 1 xx CR xx stands for control object code 10 All Zones of Main unit 1 20 All Zones of Main unit 2 30 All Zones of Main unit 3 11 Zone1 of Main unit 1 12 Zone2 of Main unit 1 13 Zone3 of Main unit 1 21 Zone1 of Main unit 2 22 Zone2 of Main unit 2 23 Zone3 of Main unit 2 ...

Page 25: ...status hh Balance control status ii Source control status jj keypad connecting status 00 disconnect 01 connected Inquiry command structure 2 xxPP CR xx stands for control object code 10 All Zones of Main unit 1 20 All Zones of Main unit 2 30 All Zones of Main unit 3 11 Zone1 of Main unit 1 12 Zone2 of Main unit 1 13 Zone3 of Main unit 1 14 Zone4 of Main unit 1 PP Stands for control action code PA ...

Page 26: ...rce 3 Name display Key in 4 CR change Source 4 Name display Key in 5 CR change Source 5 Name display Key in 6 CR change Source 6 Name display Key in M CR change the name display on keypad when turned on Key in 9600 CR change RS232 speed rate to 9600 Key in 19200 CR change RS232 speed rate to 19200 Key in 38400 CR change RS232 speed rate to 38400 Key in 57600 CR change RS232 speed rate to 57600 Key...

Page 27: ... control status jj keypad connect status 00 disconnect 01 connected Inquiry command structure 2 xxPP CR xx stands for control object code 10 All Zone of Main unit 1 20 All Zone of Main unit 2 30 All Zone of Main unit 3 11 Zone1 of Main unit 1 12 Zone2 of Main unit 1 13 Zone3 of Main unit 1 14 Zone4 of Main unit 1 PP Stands for control action code PA PA control PR Power control MU Mute control DT D...

Page 28: ...change Source 4 Name display on the keypad when the keypad is turned on Key in 5 CR change Source 5 Name display on the keypad when the keypad is turned on Key in 6 CR change Source 6 Name display on the keypad when the keypad is turned on Key in M CR change the name in the display on the keypad when the keypad is turned on Key in 9600 CR change RS232 speed rate to 9600 Key in 19200 CR change RS23...

Page 29: ...tore to download 3 Download and install the APP Note This APP is applied to TEXONIC controller and Multi Room amplifiers APP QUICK START 29 Download the control APP 1 The control APP is available for Apple iPhone iPad and Android smart phone Pad ...

Page 30: ...ce 4 Volume for individual zone 5 Mute for individual zone 6 Power ON OFF for individual zone 7 All Zones ON 8 All Zones OFF 9 Party mode All zones will be synchronize and controlled from the specific zone 10 Settings and Connection Please read the instruction in next page for properly connection 11 Streamer icon Press this icon to open the streamer APP APP QUICK START FUNCTION INSTRUCTION 30 ...

Page 31: ...nnect to the device automatically 4 Manually Enter Manually enter the device IP to connect to the device 5 MASTER SLAVE Selection When the MASTER amplifier connecting with additional SLAVE1 SLAVE2 amplifiers press one of these buttons to determine which amplifier will be controlled 6 6 Zones 4 Zones Selection Select 6 Zones or 4 Zones for corresponding MASTER SLAVE1 SLAVE2 amplifier APP QUICK STAR...

Page 32: ...tablets Wi Fi is turned on and connected to your local network 3 Please connect RX 800 to local router via Cat5 cable and then power on 4 Open Audio Cast APP 5 Two streaming will be shown on Audio Cast APP 6 Follow the instructions on Audio Cast APP to select and play music STREAMING APP QUICK START 32 ...