CC120x Evaluation Module Kit Quick Start Guide

 

 

Opening the Box and Running the Packet Error Rate Test 

 

1. Kit Contents 

 

 

 
2 x CC1200 or CC1201 Evaluation Modules 
2 x Antennas (type depending on frequency) 
 
 
Antenna types: 
868-930 MHz: Pulse W5017, 2 dBi 
420-470 MHz: Pulse SPWH24433TI, 0 dBi 

2. How to use the Modules 

 

The  EMK  is  an  add-on  kit  to  supplement  the 
CC1200DK with evaluation boards supporting 
additional  frequency  bands.  This  document 
covers the CC1200EMK and CC1201EMK. 

 
The  CC120xEM  boards  can  be  plugged  into 
several 

development 

boards 

from 

Texas 

Instruments.  Most  notably,  you  can  use  the 
SmartRF  Transceiver  EB,  which  is  included  in 
the CC1200DK. This board lets you run a packet 
error  rate  (PER)  test,  control  the  device  from 
SmartRF™  Studio  and  it  can  be  used  as  a 
development platform. 
 
It  is  also  possible  to  connect  the  EM  to  other  TI 
development 

boards 

with 

the 

appropriate 

connectors  or  to  t

he  basic  “SoC  Battery  Board”. 

The latter can be used as a carrier board for the 
EM  to  simplify  the  connection  to  other  boards 
with a microcontroller. See:  
 

http://www.ti.com/tool/soc-bb

 

 
This  guide  will  show  how  to  use  the  modules 
together with SmartRF Transceiver EB (TrxEB). 
 

3. Plug the EM into the TrxEB 

 

 

 
Insert  a  CC120xEM  board  into  the  TrxEB  as 
shown  above.  Connect  the  antenna  to  the  SMA 
connector on the EM. 

 

 

Caution! 

The 

kit 

contains 

ESD 

sensitive components. Handle with care 
to prevent permanent damage.

 

4. Select Board Mode 

 
Use  the  switches  S1  and  S2  to  select  the 
operating mode of the board. For the sake of this 
quick  start  guide,  please  select  “Enable”  and 
“UART”.  This  configuration  will  make  it  possible 
to communicate directly with the MSP430 over a 
virtual COM port on the PC. 
 

 

 
 
 

5. Power Options 

 
There are several ways of applying power to  the 
TrxEB. 
 

  2 x 1.5V AA Non-Rechargeable Alkaline 

Batteries 

  USB (5V through USB plug) 

  External Power Supply (requirements below) 

  MSP430 Debugger 

 
When  the  power  source  is  batteries  or  USB,  the 
voltage  regulators  on  the  TrxEB  will  set  the  on-
board supply voltage to 3.3VDC. 
 
External Power Supply

i

 Requirements: 

Nom Voltage: 3.3VDC 
Max Current: 800 mA 
Efficiency Level V 

 
Warning! 

To  minimize  risk  of  personal  injury  or 

property  damage,  never  use  rechargeable 
batteries to power the board.  

6. Select Power Source 

 

 

 

Depending on the power source, make sure  you 

connect  jumpers  to  the  appropriate  pins  on  the 
“Power Source” header. For instance, if you use 
batteries,  use  a  jumper  to short-circuit  pin  1  and 
2 on  the header. The  last jumper in the row (pin 
9-10)  should  always  be  mounted,  unless  the 
MSP430 FET is used as the power source. 

 

Note  that  there  should  only  be  one  active 

power  source  at  any  one  time.  Do  not  leave 
the board powered when unattended.

 

7. Welcome Screen 

 

 

 
Turn  on  power  with  the  Main  Power  switch.  You 
should now see the Texas Instruments logo  and 
a  short  description  of  the  buttons  on  the  LCD. 
Pushing any of the five buttons on the board will 
take you to the main menu. 
 

NB!  If  you  don’t  see  anything  on  the  screen 
make  sure  the  mode  switches  are  in  the 
correct positions (see step 4 above).

 

 

8. Packet Error Rate Test 

 

 

 
Select  the  PER  (Packet  Error  Rate)  test  by 
highlighting  the  selection  using  the  up/down 
buttons.  Confirm  your  selection  by  pressing 
Enter (right button). 

9. Select Test Mode 

 

 

 
The PER test can be run is several modes. Easy 
Mode  sets  up  a  one-way  test  and  uses  default 
settings.  This  test  is  convenient  for  practical 
range testing.  
 
The  other  test  modes  are  described  in  the 

TrxEB RF PER Test Software Example 

User’s 

Guide

”, available on the kit web page.

 

 
To  proceed,  h

ighlight  “Easy  Mode”  and  press 

Enter (right button). 

 

Содержание CC120 Series

Страница 1: ...UART This configuration will make it possible to communicate directly with the MSP430 over a virtual COM port on the PC 5 Power Options There are several ways of applying power to the TrxEB 2 x 1 5V...

Страница 2: ...switches are in the correct positions see step 4 above Please visit the kit web page and check for updated SW and documentation Updated SW can be downloaded to the device using IAR EW430 or SmartRF Fl...

Страница 3: ...ing the warranty period to the address designated by TI and that are determined by TI not to conform to such warranty If TI elects to repair or replace such EVM TI shall have a reasonable time to repa...

Страница 4: ...transmitter has been approved by Industry Canada to operate with the antenna types listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indic...

Страница 5: ...ified allowable ranges some circuit components may have elevated case temperatures These components include but are not limited to linear regulators switching transistors pass transistors current sens...

Страница 6: ...REMOVAL OR REINSTALLATION ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES RETESTING OUTSIDE COMPUTER TIME LABOR COSTS LOSS OF GOODWILL LOSS OF PROFITS LOSS OF SAVINGS LOSS OF USE L...

Страница 7: ...sponsible for compliance with all legal regulatory and safety related requirements concerning its products and any use of TI components in its applications notwithstanding any applications related inf...

Отзывы: