Summary of Contents for TVME220 Series

Page 1: ...E220 4 Slot IndustryPack VMEbus Carrier Version 1 1 User Manual Issue 1 1 1 January 2018 TEWS TECHNOLOGIES GmbH Am Bahnhof 7 25469 Halstenbek Germany Phone 49 0 4101 4058 0 Fax 49 0 4101 4058 19 e mai...

Page 2: ...ange the product described in this document at any time without notice TEWS TECHNOLOGIES GmbH is not liable for any damage arising out of the application or use of the device described herein Style Co...

Page 3: ...Specification August 2002 1 2 Value correction October 2002 1 3 Function added to switch S3 September 2004 1 4 Clarification of Interrupt Mapping November 2004 1 5 Update Technical Specification Apri...

Page 4: ...e 13 3 4 VME A24 A32 Base Address 14 4 IP IRQ AND CONTROL REGISTER 16 4 1 IP IRQ Configuration Register 16 4 2 IP Control Register 18 5 IP STROBE SIGNAL 20 6 INSTALLATION OF INDUSTRYPACKS 21 7 FRONT P...

Page 5: ...LE 4 3 IP CONTROL REGISTERS IP A IP B 18 TABLE 4 4 IP CONTROL REGISTERS IP C IP D 19 TABLE 7 1 IP ACK LED 22 TABLE 7 2 IP POWER LED 22 TABLE 8 1 IP J1 LOGIC INTERFACE PIN ASSIGNMENT 23 TABLE 8 2 VMEBU...

Page 6: ...nd P2 The I O mapping is compliant to the ANSI VITA 4 1 1996 standard Although the rear connectors are VME64x the electrical interface is standard VME so that nearly all CPU products still have full a...

Page 7: ...ual Issue 1 1 1 Page 7 of 26 Two Transition Modules TVME001 TM 10R and TVME002 TM 10R are available for easy access to all IP I O lines Figure 1 2 Block Diagram TVME001 TM 10R Figure 1 3 Block Diagram...

Page 8: ...TA 4 1 1996 compliant mapping of IP I O lines to VME64x connectors P0 and P2 DMA 32 MHz 32 Bit Not supported Not supported Not supported Status LEDs ACK LED for each IP Slot 5V Power LED for each IP S...

Page 9: ...tion of the switches is shown below Figure 3 1 Rotary Switch S1 S6 Step Rotary Switch Function Default Value 1 S1 S2 VME A16 Base Address 0x6000 2 S3 Interrupt Mapping VIPC6xx compatible 3 S4 VME A24...

Page 10: ...ded into the following areas IP I O space IP ID space and the IP IRQ and Control Register The IP I O space has a size of 128 bytes The size of the IP ID space and the IP IRQ and Control Register depen...

Page 11: ...0280 ID Space IP C 0x6280 0x02C0 IRQ and Control Register IP C 0x62C0 0x0300 I O Space IP D 0x6300 0x0380 ID Space IP D 0x6380 0x03C0 IRQ and Control Register IP D 0x63C0 Table 3 2 VME A16 Address Map...

Page 12: ...The difference is that access to the IP IRQ and Control Registers of the TVME220 is only possible in switch position S3 0 to 7 See Chapter VME A16 Base Address and Chapter IP IRQ and Control Register...

Page 13: ...signifies VME A24 A32 memory is disabled Positions 1 to 7 of S4 represent several memory spaces in VME A24 and with S4 F each IP has an 8 Mbytes memory space in VME A32 address space The Memory Space...

Page 14: ...e 3 5 VME A24 A32 Base Address If memory space is located in VME A24 S5 represents A 23 20 and S6 represents A 19 16 In VME A32 S5 represents A31 28 and S6 represents A 27 24 The memory base address o...

Page 15: ...0000 0x040000 0x060000 multiple of 0x080000 A24 1 Mbytes 256 Kbytes 256 Kbytes 256 Kbytes 256 Kbytes A B C D 0x000000 0x040000 0x080000 0x0C0000 multiple of 0x100000 A24 2 Mbytes 512 Kbytes 512 Kbytes...

Page 16: ...h interrupt The bits 0 4 are the LSBs and the bits 2 6 are the MSBs of the programmed IRQ level IPA IRQ Configuration Register VME A16 Base Address 0x00C1 Bit Symbol Description Access Reset Value 7 6...

Page 17: ...sabled 2 0 001 to 111 VMEbus IRQ levels IRQ1 to IRQ7 R W Depends on S3 jumper setting 1 R W 0 R W IPD IRQ Configuration Register VME A16 Base Address 0x03C1 Bit Symbol Description Access Reset Value 7...

Page 18: ...fined 4 reserved R undefined 3 reserved R undefined 2 IP A Error 1 error signal is active R 0 1 IP A INT1 Interrupt status 1 indicates a pending interrupt request R 0 0 IP A INT0 R 0 IPB Control Regis...

Page 19: ...is active R 0 1 IP C INT1 Interrupt status 1 indicates a pending interrupt request R 0 0 IP C INT0 R 0 IPD Control Register VME A16 Base Address 0x03C3 Bit Symbol Description Access Reset Value 7 IP D...

Page 20: ...ine of the IP logic interface which may be used as an optional input to or output from an IP module It is reserved for a digital strobe or clock signal related to the functionality of the IP Strobe si...

Page 21: ...g or installing the components Installing IndustryPacks on the TVME220 is done by simply snapping them into one of the four IP slots The connectors are keyed so the IndustryPack can only be installed...

Page 22: ...dicates access to IP C IP D ACK D green Indicates access to IP D Table 7 1 IP ACK LED Additionally there are 6 green Power LEDs in the front panel of the TVME220 Function Label Color Description IP A...

Page 23: ...l 7 D3 8 D4 32 DMAReq1 33 IntSel 9 D5 10 D6 34 DMAck 35 IOSel 11 D7 12 D8 36 Reserved 37 A1 13 D9 14 D10 38 DMAEnd 39 A2 15 D11 16 D12 40 Error 41 A3 17 D13 18 D14 42 IntReq0 43 A4 19 D15 20 BS0 44 In...

Page 24: ...VME_DS1 VME_BR0 VME_SYSRST 3 3V 13 NC VME_DS0 VME_BR1 VME_LWORD NC 14 GND VME_WRITE VME_BR2 VME_AM5 3 3V 15 NC GND VME_BR3 VME_A23 NC 16 GND VME_DTACK VME_AM0 VME_A22 3 3V 17 NC GND VME_AM1 VME_A21 N...

Page 25: ...25 D24 D23 D22 D21 6 GND D30 D29 D28 D27 D26 7 GND D35 D34 D33 D32 D31 8 GND D40 D39 D38 D37 D36 9 GND D45 D44 D43 D42 D41 10 GND D50 D49 D48 D47 D46 11 GND C5 C4 C3 C2 C1 12 GND C10 C9 C8 C7 C6 13 GN...

Page 26: ...A7 VME_A29 A8 B9 10 GND A9 VME_A30 A10 B10 11 B11 A11 VME_A31 A12 B12 12 GND A13 GND A14 B13 13 B14 A15 5V A16 B15 14 GND A17 NC A18 B16 15 B17 A19 NC A20 B18 16 GND A21 NC A22 B19 17 B20 A23 NC A24...