background image

Page 1  of 33  

 

 

 

 

 

Model SP-5000 HC  Thermal Printer

 

User Manual

 

 

TELPAR

 

A Platinum Equity COMPANY

 

187 Cosby Road 

Dover, New Hampshire 03820 

Toll Free: 800-872-4886 (from the U.S.A. and Canada only) 

603-750-7237  

Fax: 603-742-9938 

Website: 

www.telpar.com

 

E-mail: 

[email protected]

 

Manual SP-5000 CE/UL Version – Part No. 790136-0020 (Rev. D -  06/03) 

Summary of Contents for SP-5000 HC

Page 1: ...PAR A Platinum Equity COMPANY 187 Cosby Road Dover New Hampshire 03820 Toll Free 800 872 4886 from the U S A and Canada only 603 750 7237 Fax 603 742 9938 Website www telpar com E mail info telpar com...

Page 2: ...nt Kiosk Operation 8 2 6 1 Enable and Disable of the Delivery System Ticket Removal 10 2 6 2 Clearing a Paper Jam Condition 11 3 3 Installation 12 3 1 Power Up and Self Test 12 4 Interface Specificati...

Page 3: ...5 1 Control Codes and Escape Sequences for SP 5000 2 19 5 2 Control Codes and Escape Sequences for SP 5000 3 20 5 3 Control Codes and Escape Sequences for SP 5000 4 21 5 4 Programming Example to Show...

Page 4: ...5000 Trouble Shooting Table 29 7 2 Clearing a Paper Jam 30 8 ASCII Codes 31 9 UPC Code Chart 32 10 Controller Layout 33 11 Printer Specifications 34 11 1 Specifications 34 11 2 Telpar Roll Paper for S...

Page 5: ...SP 5000 is also capable of high density graphics MTBF 400 million min pulses 25 print ratio The SP 5000 is equipped with a dual configuration 9 pin RS 232 serial interface and a Centronics type DB 25S...

Page 6: ...all valid warranty claims either by a Repairing or replacing the defective unit at Telpar s factory or b Repairing or replacing the defective subassembly at Telpar s factory If so directed by Telpar B...

Page 7: ...access door at the pry point as shown below 2 Remove the fuse module by using a small flat blade screw driver to pry up on the edge of the fuse module The fuse module will pull straight out of the AC...

Page 8: ...power to the printer Set printer platen to the closed position via the paper release lever shown below and then feed a straight and clean leading edge of the paper directly into the paper input slot...

Page 9: ...ished by re directing the printed hardcopy below the unit By re directing the output of the printer to the queue area while printing jams due to premature hardcopy removal are eliminated The printer w...

Page 10: ...ator to quickly determine that the printer is operating correctly Telpar PART 751502 0060 for the 2 35 inch wide roll Telpar PART 751503 0060 for the 3 125 inch wide roll Telpar PART 751504 0060 for t...

Page 11: ...4 1 1 SW1 Switch Settings 1 2 3 4 5 6 7 8 Baud Rate Stop Parity Data Parity Delivery Bits Length Odd System Even Setting 600 Close Open Open 1 200 Open Close Open 2 400 Close Close Open 4 800 Open Ope...

Page 12: ...a host computer s serial port A DB 25S connector is used for the parallel interface The pin assignments and brief signal descriptions are listed below Pin Signal Description 1 STROBE 1 sec pulse to c...

Page 13: ...ns 2 and 3 4 4 3 2 Firmware Changes Firmware Revision D4 01 or higher is required 4 5 Parallel Interface Cable This parallel cable configuration is used to interface the SP 5000 with all IBM and IBM c...

Page 14: ...ll be reduced to fit on the 3 15 wide SP 5000 3 print area It is recommended that the user installs both drivers and experiments until the resolution that meets the application is determined 4 6 3 SP...

Page 15: ...t page It is useful in determining if the installation was successful The printer MUST be turned on and ready to receive data If it is not select No and you can run the test later 11 After Clicking th...

Page 16: ...ver is now installed you may now close and exit the Print Manager The printer can be set as the Default printer for Windows NT or the printer can be accessed from within Windows NT applications 11 If...

Page 17: ...i n1 n2 105 69 Bar Code Interleaf 2 of 5 n1 Horizontal Offset n1x8 dots offset n2 Height of Code n2x32 dots high Used with ESC h n 104 68 Horizontal Graphics Tab n 1 255 Optional ESC j n 106 6A Line F...

Page 18: ...n2 105 69 Bar Code Interleaf 2 of 5 n1 Horizontal Offset n1x8 dots offset n2 Height of Code n2x32 dots high Used with ESC h n 104 68 Horizontal Graphics Tab n 1 255 Optional ESC j n 106 6A Line Feed i...

Page 19: ...2 105 69 Bar Code Interleaf 2 of 5 n1 Horizontal Offset n1x8 dots offset n2 Height of Code n2x32 dots high Used with ESC h n 104 68 Horizontal Graphics Tab n 1 255 Optional ESC j n 106 6A Line Feed in...

Page 20: ...ch bank can accept 16KB 7Bytes of data for a total of 16377 Bytes per bank Calculate the Number of Banks Required Divide the image size 24 576 by the Bytes per bank 16377 24576 16377 1 5006 Banks Roun...

Page 21: ...th the SP 5000 driver diskette to down load data to the printer 10 LPRINT CHR 27 q CHR 0 20 SYSTEM Prints file 24 576 Bytes starting with the first bank 0 defaults to print all banks 5 6 Horizontal Gr...

Page 22: ...1B 63 0D Code Legend 0D Carriage return and 13 byte print command in horz graphics 0D HEX 13 DECIMAL 1B Escape 6A Horizontal Line Feed Command C8 Decimal equivalent of 200 dot spacing from top of form...

Page 23: ...100 LPRINT CHR 27 c REM Cut 5 7 2 3 of 9 Bar Code Description The bar code printing option allows code 39 character strips to be printed by the SP 5000 Code 39 is so named because of the original 39 c...

Page 24: ...e product s manufacturer and the next five digits represent the product code The final digit is a check digit whose value is mathematically based on all of the other numbers coded in the symbol A weig...

Page 25: ...will output information from the RS 232 Interface only Bit Weight Description 0 Paper Low 1 1 Paper Out 1 2 Cutter Jam 1 3 Ticket Taken 1 4 For Future Use 5 Buffer Full 1 6 Buffer Empty 1 7 For Futur...

Page 26: ...The SP 5000 exterior cabinet may be cleaned with a non abrasive cleanser Care should be taken to prevent liquids from entering inside the mechanical assembly If in a dirty environment the mechanism m...

Page 27: ...not hold line feed long enough Paper not installed properly Paper jam Defective line feed switch Paper release lever Up Check as outlined above Hold line feed longer Check roll orientation Clear jam...

Page 28: ...lever 10 Light print Wrong paper poor quality Paper release not locked Paper partially jammed Use Telpar paper Check paper release lever Check mechanism for jam 11 Delivery jam Wrong paper paper wound...

Page 29: ...uide and cutter assembly may be rotated upward to gain access to the mechanism output cutter input area To rotate the output assembly 1 Turn the unit off and remove primary power by disconnecting the...

Page 30: ...6D m 38 26 62 3E 86 56 V 110 6E n 39 27 63 3F 87 57 W 111 6F o 40 28 64 40 88 58 X 112 70 p 41 29 65 41 A 89 59 Y 113 71 q 42 2A 66 42 B 90 5A Z 114 72 r 43 2B 67 43 C 91 5B 115 73 s 44 2C 68 44 D 92...

Page 31: ...45 in Abrasion life 90 km 56 miles of paper travel Humidity 90 max RH non condensing Weight Standard configuration 3 6 kg 8 0 lbs Barcode embedded symbologies 3 of 9 UPC A Interleaved 2 of 5 4 sizes o...

Page 32: ...accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment do...

Page 33: ...ddress 187 Cosby Road Dover New Hampshire 03820 Telephone 603 750 7237 Fax 603 742 9938 Type of Equipment Printer Model Number SP 5000 Serial Number All numbers beginning with 5000C Year of affixing C...

Reviews: