TDS20065

Quick Installation Guide

Summary of Contents for TDS20065

Page 1: ...TDS20065 Quick Installation Guide...

Page 2: ...t Power Power Plug RS232 Port L1 HVAC Line 1 L2 HVAC Line 2 RS485 Ethernet Port GPIOs L7 HVAC Line 7 L6 HVAC Line 6 L5 HVAC Line 5 L4 HVAC Line 4 USB Device Port DIP Switches P Q R S LCD Touch Screen...

Page 3: ...y systems the connection is at oudoor units only Polarity is not required on the HVAC communication line Centralized group address required 2 Connecting to the line plug Secure the cables in the L1 li...

Page 4: ...nits M2 For Heat Recovery systems the connection is at outdoor units only Polarity is not required on the HVAC communication line 2 Connecting to the line plug Secure the cables in the L1 line plug 3...

Page 5: ...on HVAC communication line L1 2 If no DC voltage Daikin 14 16V DC change the dip switches as shown below 3 Turn ON the power for TDS20065 and connect it to HVAC line 4 Connect to the communication te...

Page 6: ...mmunication line L1 2 If no DC voltage Mitsubishi 28 30V DC change the dip switches as shown below 3 Turn ON the power for TDS20065 and connect it to HVAC line 4 Connect to the communication terminals...

Page 7: ...the connection is at outdoor units only Polarity is not required on the HVAC communication line 2 Connecting to the line plug Secure the cables in the L1 line plug 3 Plugging to the TDS20065 Insert t...

Page 8: ...tems the connection is at outdoor units only Polarity is not required on the HVAC communication line 2 Connecting to the line plug Secure the cables in the L1 line plug 3 Plugging to the TDS20065 Inse...

Page 9: ...For Heat Recovery systems the connection is at outdoor units only Polarity is not required on the HVAC communication line 2 Connecting to the line plug Secure the cables in the L1 line plug 3 Pluggin...

Page 10: ...For Heat Recovery systems the connection is at outdoor units only Polarity is not required on the HVAC communication line 2 Connecting to the line plug Secure the cables in the L1 line plug 3 Pluggin...

Page 11: ...r units Q For Heat Recovery systems the connection is at outdoor units only Polarity is not required on the HVAC communication line 2 Connecting to the line plug Secure the cables in the L1 line plug...

Page 12: ...For Heat Recovery systems the connection is at outdoor units only Polarity is not required on the HVAC communication line 2 Connecting to the line plug Secure the cables in the L1 line plug 3 Plugging...

Page 13: ...tdoor or indoor A Mitsubishi Heavy Max 128 indoor units B 2 Connecting to the line plug Secure the cables in the L7 line plug 3 Plugging to the TDS20065 Insert the plug in to the TDS20065 L7 socket 4...

Page 14: ...outdoor or indoor InterA LG Max 128 indoor units InterB 2 Connecting to the line plug Secure the cables in the L7 line plug 3 Plugging to the TDS20065 Insert the plug in to the TDS20065 L7 socket 4 Ch...

Page 15: ...t HVAC outdoor only A Gree Max 16 indoor units B 2 Connecting to the line plug Secure the cables in the L7 line plug 3 Plugging to the TDS20065 Insert the plug in to the TDS20065 L7 socket 4 Check DIP...

Page 16: ...ion terminals on the HVAC equipment HVAC outdoor only X Midea Max 64 indoor units Y E 2 Connecting to the line plug Secure the cables in the L7 line plug 3 Plugging to the TDS20065 Insert the plug in...

Page 17: ...HVAC outdoor only R1 Samsung Max 64 indoor units R2 2 Connecting to the line plug Secure the cables in the L7 line plug 3 Plugging to the TDS20065 Insert the plug in to the TDS20065 L7 socket 4 Check...

Page 18: ...HVAC equipment HVAC outdoor only X Trane Max 64 indoor units Y E 2 Connecting to the line plug Secure the cables in the L7 line plug 3 Plugging to the TDS20065 Insert the plug in to the TDS20065 L7 s...

Page 19: ...HVAC outdoor only R1 Tane US Max 64 indoor units R2 2 Connecting to the line plug Secure the cables in the L7 line plug 3 Plugging to the TDS20065 Insert the plug in to the TDS20065 L7 socket 4 Check...

Page 20: ...VAC outdoor only X Kentatsu Max 64 indoor units Y E 2 Connecting to the line plug Secure the cables in the L7 line plug 3 Plugging to the TDS20065 Insert the plug in to the TDS20065 L7 socket 4 Check...

Page 21: ...ipment HVAC outdoor only X Chigo Max 64 indoor units Y E 2 Connecting to the line plug Secure the cables in the L7 line plug 3 Plugging to the TDS20065 Insert the plug in to the TDS20065 L7 socket 4 C...

Page 22: ...dapter is required for connecting up to two Gree GMV5 VRF lines Please contact support This adapter includes a CAN bus 120 resistor 3 Plugging to the TDS20065 Insert the plug in to the TDS20065 L8 USB...

Page 23: ...128 indoor units X2 2 Connecting to the TDS20066 adapter TDS20066 USB Network Interface TP FT 10 adapter is required for connecting to Fujitsu VRF 3 Connect Echelon via USB Extension cable Connect th...

Page 24: ...128 indoor units X2 2 Connecting to the TDS20066 adapter TDS20066 USB Network Interface TP FT 10 adapter is required for connecting to Rheem VRF 3 Connect Echelon via USB Extension cable Connect the...

Page 25: ...ine All ON OFF operation button Scrollbar Connected indoor unit with it s address and Set Point temperature indication Service settings button TDS20065 MAC address TDS20065 IP address CoolRemote conne...

Page 26: ...Mounting on a DIN rail 1 Place the device mounting feet on the DIN rail To unmount pull the mounting lock down 2 Push on the lower part of the device onto the the DIN rail to lock it in place...

Page 27: ...40 Mounting on a wall...