background image

User Manual

T3AFG5 and T3AFG10 Series Function/Arbitrary

Waveform Generator

Summary of Contents for T3AFG10 Series

Page 1: ...User Manual T3AFG5 and T3AFG10 Series Function Arbitrary Waveform Generator ...

Page 2: ...I Declaration Copyright Teledyne Test Tools All rights reserved Contents in this Manual are not allowed to be copied extracted and translated without permission from Teledyne Test Tools ...

Page 3: ...ng conductor must be connected to the earth ground Make sure that the instrument is properly grounded before connecting the input or output terminals Observe all the ratings of the terminal To avoid fire or shock observe all the ratings and symbols that marked on the instrument Read the user guide carefully before making connections to the instrument Do not operate without Covers Do not operate th...

Page 4: ...ion Do not operate in wet damp conditions Do not operate in an explosive atmosphere Keep the product s surfaces clean and dry Not position the equipment so that it is difficult to operate the disconnecting device detachable plug ...

Page 5: ...AT IV Not to use the equipment for measurements on mains circuits not to use the equipment for measurements on voltage exceed the voltage range describe in the manual Only probe assemblies which meet the manufacturer s specifications shall be used The Responsible body or operator should refer to the instruction manual to preserve the protection afford by the equipment If the equipment is used in a...

Page 6: ...quipment DOUBLE INSULATION PROTECTIVE EARTH TERMINAL This electronic product is subject to disposal and recycling regulations that vary by country and region Many countries prohibit the disposal of waste electronic equipment in standard waste receptacles For more information about proper disposal and recycling of your Teledyne LeCroy product visit teledynelecroy com recycle Rated for indoor use on...

Page 7: ...tion Arbitrary Waveform Generator has a clear and simple front panel The user friendly panel layout and instructions versatile terminals direct graph interface built in instructions and help system have greatly simplified the operation process with the help of which users do not have to spend a great deal of time learning and familiarizing the operation of the generator before they can use it prof...

Page 8: ...defined arbitrary waveform Multiple modulation function AM FM PM ASK FSK PWM DSB AM Sweep and Burst Multiple interfaces USB host USB device USBTMC Support USB storage device Software updating could also be performed using USB devices Up to 16k sample points of internal waveform depth which can rebuild or simulate any complex waveform 2 languages English and Chinese user interface and built in help...

Page 9: ...Input 15 1 8 To Use Store Utility Help Function 16 2 Operating Your Generator 17 2 1 To Set Sine Signals 18 2 2 To Set Square Signals 23 2 3 To Set Ramp Signals 26 2 4 To Set Pulse Signals 29 2 5 To Set Noise Signals 33 2 6 To Set Arbitrary Signals 35 2 7 To Generate the Modulated Waveform 42 2 8 To Generate Sweep 51 2 9 To Generate Burst 53 2 10 To Store and Recall 57 2 11 To Set the Utility Func...

Page 10: ...r Wave 95 3 8 Example 8 Generate a Burst Wave 97 3 9 Example 9 Generate an AM Wave 99 3 10 Example 10 Generate a FM Wave 101 3 11 Example 11 Generate a PM Wave 103 3 12 Example 12 Generate a FSK Wave 105 3 13 Example 13 Generate an ASK Wave 107 3 14 Example 14 Generate a PWM Wave 109 3 15 Example 15 Generate a DSB AM Wave 111 4 Troubleshooting 113 General Inspecting 113 Troubleshooting 114 5 Servi...

Page 11: ...ted This chapter covers the following topics General Inspection Handle Adjustment The Front Rear Panel To Set a Waveform To Set Modulate Sweep Burst To Set Output To Use Digital Input To Use Store Utility Help Function ...

Page 12: ...the instrument are listed in chapter 6 Appendix A Accessories If the contents are incomplete or damaged please notify your sales representative 3 Inspect the instrument In case any mechanical damage or defect or if the instrument does not operate properly or pass performance tests notify your sales representative If the shipping container is damaged or the cushioning materials show signs of stress...

Page 13: ...ust the handle position of T3AFG5 10 Function Arbitrary Waveform Generator please grip the handle by the sides and pull it outward Then make the handle rotate to the desired position Figure 1 1 Viewing Position and Carrying Position ...

Page 14: ... a clear and simple front panel See Figure 1 2 and Figure 1 3 The front panel has a knob and functional keys The 5 blue grey buttons on the right side of the screen are menu buttons named F1 to F5 from top to bottom with the help of which you can enter different functions menu or have direct specific applications The signal input and output interfaces are set at the front and rear panels which can...

Page 15: ...ont Panel of T3AFG5 10 Series Figure 1 4 Rear Panel of T3AFG5 10 Series USB Device Power Socket USB Host Waveform keys Number keys Knob Power LCD Display Menu Function Operation keys Output Control Direction keys Back ...

Page 16: ...ons Please note that the signs for the functional buttons on the operation panel are represented by squared words such as Sine which represents the transparent functional key with Sine on it on the front panel while the menu buttons are represented by brighten words such as Freq which means the frequency option in the Sine menu Waveform Display area Parameter area Operation Menu ...

Page 17: ...ection settings Figure 1 6 Waveform Selection Buttons 1 Press Sine button and the waveform window will display sine waveform T3AFG5 10 Series Generator can generate sine signal with a frequency from 1μHz to 30MHz By setting frequency period amplitude high level offset low level sine signal with different parameters can be generated Figure 1 7 Sine Signal Display Interface ...

Page 18: ...uare signal with a frequency from 1μHz to 5MHz or 10MHz and variable duty cycle Figure 1 8 Square Signal Display Interface As is shown in Figure 1 8 the default signal parameters are 1kHz frequency 4 0Vpp amplitude 0Vdc offset and 50 duty cycle 3 Press Ramp button and the waveform window displays ramp waveform T3AFG5 10 Series Generator can generate ramp signal with a frequency of from 1μHz to 300...

Page 19: ...are 1kHz frequency 4 0Vpp amplitude 0Vdc offset and 50 symmetry 4 Press Pulse button and the waveform window displays pulse waveform T3AFG5 10 Series Generator can generate pulse signal with a frequency from 500μHz to 5 MHz and variable pulse width and delay Figure 1 10 Pulse Signal Display Interface ...

Page 20: ...enerator can generate noise signal with a band width up to 5MHz or 10MHz depending on the model Figure 1 11 Noise Signal Display Interface As is shown in Figure 1 11 the default signal parameters are 128mV Stdev and 0V Mean 6 Press Arb button and the waveform window displays arbitrary waveform T3AFG5 10 Series Generator can generate repeatable arbitrary waveform signals with at most 16K points and...

Page 21: ...11 Figure 1 12 Arbitrary Waveform Signal Display Interface As is shown in Figure 1 12 the default signal parameters are 1kHz frequency 4 0Vpp amplitude and 0mVdc offset ...

Page 22: ...re 1 13 Modulate Sweep Burst Button 1 Press Mod button the modulated waveforms will be generated The modulated waveform can be changed by modifying the parameters such as type internal external modulation depth frequency waveform etc T3AFG5 10 Series can modulate waveform using AM FM PM ASK FSK PWM and DSB AM Sine square ramp and arbitrary waveforms can be modulated pulse noise and DC can not be m...

Page 23: ...se and DC can not be swept In the sweep mode T3AFG5 10 Series generate signal with variable frequencies Figure 1 15 Sweep Waveform Display Interface 3 Press Burst button burst for sine square ramp pulse or arbitrary waveform can be generated Figure 1 16 Burst Waveform Display Interface ...

Page 24: ...s Figure 1 17 Output Buttons Press Output button to activate or deactivate the output signal Term Explanation Burst Output waveforms with set cycle times Burst can last for certain times of waveform cycle N Cycle Burst or be controlled by external gated signals Gated Burst Burst applies to all kinds of waveforms but noise can only be used in gated burst Generally it is called burst function within...

Page 25: ...keypad The instruction below will help you familiarize yourself with the digital input function Figure 1 18 Front Panel Digital Input 1 The up and down keys are used to shift parameters and the left and right keys are used to shift digits 2 Keypad is used to directly set the parameters value 3 Knob is used to change a signal digit value whose range is 0 9 ...

Page 26: ...lf with these functions Figure 1 19 Store Recall Utility and Help Button 1 The Store Recall button is used to store waveform data and configure information 2 The Utility button is used to set the auxiliary system function change the output configure parameters interface setting system setting information or perform the instrument self test and read the calibration information etc 3 The Help button...

Page 27: ...ons you are suggested to read chapter one Getting Started again This chapter covers the following topics Setting Sine Signal Setting Square Signal Setting Ramp Signal Setting Pulse Signal Setting Noise Signal Setting Arb Signal Output Modulated Signal Output Sweep Signal Output Burst Signal Store Recall Utility Setting Help System You are suggested to read this chapter carefully so as to understan...

Page 28: ...veforms are frequency period amplitude high level offset low level and phase Different sine signals are generated by setting these parameters As is shown in Figure 2 1 in the soft key menu select Freq Cursor is located in the frequency parameter area in the parameter display window and users can set the frequency value here Figure 2 1 Sine Parameter Display Interface ...

Page 29: ...r the current operation is displayed in inverse color 2 Input the desired frequency Use the keypad to input the parameter value directly and press the corresponding button to select the parameter unit Or you can use the direction button to select the digit you want to edit and then use the knob Function menu Explanations Freq Period Set the signal frequency or period The current parameter will be ...

Page 30: ...ction if the current value is valid for the new waveform it will be used sequentially If you want to set the waveform by high level or low level press the Ampl HLevel or Offset LLevel button again to switch into the high level or low level parameter the current operation is displayed in Instruction When using the keypad to enter the digit you can use the left direction button to move the cursor ba...

Page 31: ...tput Offset 1 Press Sine Offset to set the offset The offset shown on the screen when the instrument is powered is the default value or the set value beforehand When changing the function if the current value is valid for the new waveform it will be used sequentially 2 Input the desired Offset Use the keypad or the knob to input the desired value choose the unit and press the corresponding button ...

Page 32: ...22 Figure 2 5 Setting the Offset ...

Page 33: ... Square operation menu The parameters of Square waveforms are frequency period amplitude high level offset low level phase and duty As is shown in Figure 2 6 select Duty Cursor is located in the duty parameter area in the parameter display window and users can set the duty value here Figure 2 6 Square Parameter Display Interface ...

Page 34: ...e or the set value beforehand When changing the function if the current value is valid for the new waveform it will be used sequentially Function Menu Settings Explanation Freq Period Set the signal frequency or period The current parameter will be switched at a second press Ampl HLevel Set the signal amplitude or high level The current parameter will be switched at a second press Offset LLevel Se...

Page 35: ...the desired Duty Cycle Use the keypad or the knob to input the desired value choose the unit and press the corresponding button The generator will change the waveform immediately Figure 2 8 Setting the Duty Cycle ...

Page 36: ... The parameters for ramp waveforms are frequency period amplitude high level offset low level phase and symmetry As is shown in Figure 2 9 in the soft key menu select Symmetry Cursor is located in the symmetry parameter area in the parameter display window and users can set the symmetry value here Figure 2 9 Ramp Parameter Display Interface ...

Page 37: ...y Function Menu Settings Explanation Freq Period Set the signal frequency or period The current parameter will be switched at a second press Ampl HLevel Set the signal amplitude or high level The current parameter will be switched at a second press Offset LLevel Set the signal offset or low level The current parameter will be switched at a second press Phase Set the phase of the signal Symmetry Se...

Page 38: ...t the desired Symmetry Use the keypad or the knob to input the desired value choose the unit and press the corresponding button The generator will change the waveform immediately Figure 2 11 Setting the Symmetry ...

Page 39: ...ameters for pulse waveforms are frequency period amplitude high level offset low level pulse width Duty and Rise Fall As is shown in Figure 2 12 in the soft key menu select PulWidth Cursor is located in the pulse width parameter area in the parameter display window and users can set the pulse width value here Figure 2 12 Pulse Parameter Display Interface ...

Page 40: ...t the signal amplitude or high level The current parameter will be switched at a second press Offset LLevel Set the signal offset or low level The current parameter will be switched at a second press PulWidth Duty Set the signal pulse width or duty The current parameter will be switched at a second press Rise Fall Setting the rising edge for pulse waveform Setting the falling edge for pulse wavefo...

Page 41: ... 1 Press Pulse Rise to set the Rise edge The rising edge shown on the screen when the instrument is powered is the default value or the set value beforehand When changing the function if the current value is valid for the new waveform it will be used sequentially 2 Input the desired rising edge Use the keypad or the knob to input the desired value choose the unit and press the corresponding button...

Page 42: ...32 Figure 2 15 Setting the Rise edge ...

Page 43: ...ration menu The parameters for noise waveforms are Stdev and mean As is shown in Figure 2 16 in the soft key menu select Stdev Cursor is located in the Stdev parameter area in the parameter display window and users can set the Stdev value here Noise is non regulated signal which has no frequency or period Figure 2 16 Noise Parameter Display Interface ...

Page 44: ...34 Figure 2 17 Table 2 5 Menu Explanations of Noise Waveform Function Menu Settings Explanation Stdev Set the signal standard deviation Mean Set the signal mean ...

Page 45: ...parameters are set by using the Arb operation menu The Arb signal consists of two types the system built in waveform and the user definable waveform The parameters for Arb waveforms are frequency period amplitude high level offset low level and phase Figure 2 18 Arb Parameter Display Interface ...

Page 46: ...or period The current parameter will be switched at a second press Ampl HLevel Set the signal amplitude or high level The current parameter will be switched at a second press Offset LLevel Set the signal offset or low level The current parameter will be switched at a second press Phase Set the phase of the signal Function Menu Settings Explanation Load Wform Select the built in arbitrary signal as...

Page 47: ...of Built in Arbitrary Waveform 1 To Select the Built in Waveform Press Arb Load Wform Built In and enter the following interface As is shown in Figure 2 22 there are five kinds of arbitrary waveform Function Menu Settings Explanation Built In Select one of the 46 types built in arbitrary waveforms Stored Wforms Select one of arbitrary waveforms stored in the non volatile memory Cancel Cancel the c...

Page 48: ...m Winfun Triangle Select windows function triangle waveform Select Validate the built in waveform Function Menu Settings Explanation StairUp Select the built in stair up waveform StairDn Select the built in stair down waveform StairUD Select the built in stair up and down waveform PPulse Select the built in positive pulse waveform NPulse Select the built in negative pulse waveform Trapezia Select ...

Page 49: ...ogarithmic rise waveform Sqrt Select the built in square root waveform Root3 Select the built in Root3 waveform X 2 Select the built in X 2 waveform X 3 Select the built in X 3 waveform Sinc Select the built in sinc waveform Sinc sin x x Gaussian Select the built in gaussian waveform Dlorentz Select the built in D lorentz waveform Haversin Select the built in haversine waveform Lorentz Select the ...

Page 50: ...oise waveform Function Menu Settings Explanation Hamming Select the built in hamming window waveform Hanning Select the built in hanning window waveform Kaiser Select the built in kaiser window waveform Blackman Select the built in blackman windows waveform Gaussian Select the built in gaussian window waveform Triangle Select the built in triangle window waveform Hairs Select the built in hairs wi...

Page 51: ...the following interface As is shown in Figure 2 27 use the direction keys or knob to choose the corresponding arbitrary waveform and press Select Figure 2 27 Stored Wform Display Interface Atan Select the built in tangent waveform Acot Select the built in inverse cotangent waveform ...

Page 52: ... users can set the modulating frequency frequency deviation modulating waveform and carrier waveform In ASK users can set the Key Freq and carrier waveform In FSK users can set the key frequency Hop Freq and carrier waveform In PM users can set the phase deviation modulating frequency modulating waveform and carrier waveform We will cover how to set these parameters in details according to the mod...

Page 53: ...ation Depth The amplitude range also called Percentage Modulation Modulation depth varies from 0 to 120 In the 0 modulation the output amplitude is the half of the set value In the 100 modulation the output amplitude is the same as the set value Function Menu Settings Explanation AM Freq Set the modulating waveform frequency Frequency range 2mHz 20kHz internal source only AM Depth Set the amplitud...

Page 54: ...face of FM Waveform Parameter Press Mod Type FM to enter the following menu Figure 2 31 Table 2 15 Menu Explanations of the FM Parameters Function Menu Settings Explanation FM Freq Set the modulating waveform frequency Frequency range 2mHz 20kHz internal source FM Dev Set the maximum frequency deviation Type FM Frequency modulation Shape Sine Square Triangle UpRamp DnRamp Noise Arb Choose the modu...

Page 55: ... stream modulating signal keeping frequency and phase constant The parameters for the ASK are as shown in Figure 2 32 Figure 2 32 Setting Interface of ASK Waveform Parameter Term Explanation Frequency Deviation The deviation should be equal to or less than the carrier waveform frequency The sum of the deviation and the carrier frequency should be equal to or less than maximum frequency of the sele...

Page 56: ...ble 2 16 Menu Explanations of the ASK Parameters Function Menu Settings Explanation Key Freq Set the frequency at which the output amplitude shifts between the carrier amplitude and zero internal modulation only 2mHz 50kHz Type ASK Amplitude shift keying modulation ...

Page 57: ...alled the key frequency Figure 2 34 Setting Interface of FSK Waveform Parameter Press Mod Type FSK to enter the following interface Figure 2 35 Table 2 17 Menu Explanations of the FSK Parameters Function Menu Settings Explanation Key Freq Set the frequency at which the output frequency shifts between the carrier frequency and the hop frequency internal modulation only 2mHz 50kHz Type FSK Frequency...

Page 58: ...2 36 Figure 2 36 Setting Interface of PM Waveform Parameter Press Mod Type PM enter the following interface Figure 2 37 Table 2 8 Menu Explanations of the PM Parameters Function Menu Settings Explanation PM Freq Set the modulating waveform frequency Frequency range 2mHz 20kHz Phase Dev Range from 0 360 Type PM Phase modulation Shape Sine Square Triangle UpRamp DnRamp Noise Arb Choose the modulatin...

Page 59: ... PMW are as shown in Figure 2 38 Figure 2 38 Setting Interface of PWM Waveform Parameter Press Mod Pulse PWM to enter the following menu Figure 2 39 Table 2 19 Menu Explanations of the PWM Parameters Function Menu Settings Explanation PWM Freq Set the modulating waveform frequency 2mHz 20kHz Width Dev Duty Dev Set the width or Duty range Type PWM Amplitude modulation Shape Sine Square Triangle UpR...

Page 60: ...ure 2 41 Table 2 20 Menu Explanations of the DSB AM Parameters Function Menu Settings Explanation DSB Freq Set the modulating waveform frequency Frequency range 2mHz 20kHz Type DSB AM Amplitude modulation Shape Sine Square Triangle UpRamp DnRamp Noise Arb Choose the modulating waveform To change the carrier waveform parameter press Sine Square Ramp Arb ...

Page 61: ...o the stop frequency at the sweep time you specify Sweep can be generated by sine square ramp or arbitrary waveforms pulse noise and DC are not allowed Figure 2 42 Setting Interface of Sweep Waveform Parameter Press Sweep button to enter the following menu Set the waveform parameters by using the operation menu ...

Page 62: ...t the time span of the sweep in which the frequency changes from the start frequency to stop frequency Stop Freq Freq Span Set the stop frequency of the sweep Set the frequency span of the sweep Start Freq Mid Freq Set the start frequency of the sweep Set the center frequency of the sweep Source Internal Choose internal source External Choose external source Manual Set the start and stop time by h...

Page 63: ... waveform cycles N Cycle burst or when external gated signals gated burst is applied any waveform could be used but noise can only be used in Gated Burst Press Burst button to enter the following interface Set the waveform parameters by using the operation menu Figure 2 45 Setting Interface of Burst Waveform Parameter ...

Page 64: ... a burst Burst Period Carrier Period Burst Number Start Phase Define the start point in a waveform The phase varies from 0 to 360 and the default setting is 0 For an Arbitrary Waveform 0 is the first waveform point Function Menu Settings Explanation Period Set the burst Period Start Phase Set the start phase of the burst NCycle Gated Use the N Cycle mode Use the Gated mode Source Internal Choose i...

Page 65: ...e 1 to 50 000 or Infinite If you choose Infinite then a continuous waveform will be generated which will not stop until a trigger event happens If required Burst Period will increase to cater to the specific number of cycles For an infinite cycle burst external or manual trigger is needed to activate the burst Function Menu Settings Explanation Cycles Infinite Set the number of the bursts in a N C...

Page 66: ... is 240ns Set the Gated Burst Press Burst Gated to enter the following interface Figure 2 48 Table 2 25 Menu Explanations of the Gated Burst Parameters Function Menu Settings Explanation NCycle Gated Set the NCycle mode Set the gated mode Polarity Positive Negative Set the polarity for the gated signal ...

Page 67: ... documentation saved via CSV from the Oscilloscope Figure 2 49 Save and Read Interface Figure 2 50 Table 2 26 Menu Explanations of Save and Recall Page 1 2 Function Menu Settings Explanation File Type State Data The setting of the generator Arbitrary waveform file Browser Directory File Shift between the directory and file Save Save the waveform to the appointed place Recall Recall the waveform or...

Page 68: ...atile memories The state storage will memorize the selected function including the arbitrary waveform frequency amplitude DC offset duty cycle symmetry and other modulation parameter used To save the instrument state the procedures are given as followed 1 Choose the file type to store Press Store Recall Type State and choose state as the storage type 2 Choose the location of the file There are ten...

Page 69: ...1 USB Storage Interface 1 Install the USB Device Insert the USB Device into the USB interface on the front panel and the screen will show USB flash device plug in and storage menu will show USB Device A 2 Choose the USB Device Press Browser Directory move the cursor with the up or down direction key to select USB Device A Press the right key to open the lower directory use the up and down directio...

Page 70: ...portable hard disk is not supported To Save a File Press Store Recall Store to enter the following interface Enter the desired file name in the File Name frame In the middle of the figure below is the input keypad used to edit the file name Use the up and down direction keys and knob to select the desired character use the left and right direction keys to edit the input file name Figure 2 52 File ...

Page 71: ...teps below Figure 2 54 English Input Interface 1 Press InType En to enter the English interface 2 Input the file name NEWFILE Use the Knob to adjust the cursor s horizontal position and the up and Function Menu Settings Explanation Input Type En English input Select Select the current character Delete Delete the current character Save Store the file with the current name ...

Page 72: ...and press Select Repeat this until you have inputted NEWFILE 3 Edit the File Name When you have entered a wrong character move the cursor to the wrong character to be deleted and press Delete to remove it Re enter the file name 4 Press Save to finish and save the file ...

Page 73: ...meter setting for Load HighZ and Normal Inverse The System Setting provides the setting for Language Display Beep Screen Guard Format Power System Configure and default setting Test provides the self testing and calibration function Press Utility button to enter the Utility Menu Its functions are listed below in Figure 2 55 Figure 2 55 Table 2 28 Menu Explanations of Utility System Setting Page1 2...

Page 74: ... DC On to enter the following interface Please note that there is a DC On sign at the middle left of the screen Figure 2 57 DC Setting Interface Function Menu Settings Explanation System Set the system configuration Test Cal Test and calibrate the instrument EditInfo Information of the system Update Update function ...

Page 75: ...lly To Set IO Press Utility IO Setup to set the IO interface The equipment supports RAW protocol and TMC protocol user may setup corresponding protocol by IO Setup To Set Output Parameter Press Utility Output Setup to enter the following interface Figure 2 58 Table 2 30 Menu Explanations of Output Setting Page 1 2 Function Menu Settings Explanation Load HighZ Set the load connected to the Output C...

Page 76: ...e load Press Utility Output Setup Load to enter the following interface Please note that the load parameter shown on the right bottom is the default setting when the power is on or the pre set load value If the current value is valid for the output then current value will be used Figure 2 59 Set the Output Load Instruction T3AFG5 10 Series has a fixed 50Ω Series Impendence No matter what value the...

Page 77: ...connected to the Sync connector activated When the Sync Signal is disabled the output voltage of the Sync connector is level low In the Inverse Mode the Waveform that corresponds to the Sync Signal does not invert The Sync Signal is a Pulse Signal with fixed positive pulse width which is more than 50ns For non modulated waveform the Sync Signal reference is the carrier For internal modulating AM F...

Page 78: ...nu Settings Explanation Number format Set the number format Language Set the display language Power On Default Last All the settings return to default when powered All the settings return to the last one when powered Set to Default Set all the settings to default Function Menu Settings Explanation Beep On Off Open beep Close beep ScrnSvr 1min 5min 15min 30min 1hour 2hour 5hour Activate the screen ...

Page 79: ...the instrument is first powered on Beep Activate or deactivate the sound when an error occurs from the front panel or the remote interface Activate or deactivate any sound made by the button or knob on the front panel The current setting is stored in the non volatile memory 1 Set the Format Press Utility System Number Format to enter the following interface Figure 2 61 Set the number Format ...

Page 80: ... On the example is as followed Figure 2 63 Set Format 2 as point press Separator On the example is as followed Figure 2 64 Set Format 3 as point press Separator Off the example is as followed Function Menu Settings Explanation Point Using dot to represent point Using comma to represent point Separator On Off Space Enable the Separator Close the Separator Use Space to separate Figure 2 65 Set Forma...

Page 81: ...ormat 6 as point press Separator Space the example is as followed Figure 2 68 Set Format 2 Language Setup The T3AFG5 10 Series Generator offers two languages English and Simplified Chinese for user to choose To Select Language press Utility and then Language to select the language The Procedure is as followed Press Utility System Language to change the language ...

Page 82: ...ave Frequency 1kHz Amplitude Offset 4Vpp 0Vdc Phase 0 Terminals High Z Modulation Default Carrier 1kHz Sine Wave Modulating 100Hz Sine Wave AM Depth 100 FM Deviation 500Hz Key Freq 100Hz Key Freq 100Hz FSK Hop Frequency 1MHz Phase Deviation 180 Sweep Default Start Stop Frequency 100Hz 1 9kHz Sweep Time 1S Trig Out Off Mode Linear Direction Burst Default Period 10ms Phase 0 Count 1Cycle Trig Off Tr...

Page 83: ...ility Test Cal to enter the following menu Figure 2 69 Test Cal function Menu Figure 2 70 Table 2 35 Menu Explanations of Test Setting Function Menu Settings Explain SelfTest Perform system self test SelfCal Do self calibration ...

Page 84: ...t 1 Scr Test Select Scr Test to enter the screen test interface The words Press 7 Key to continue Press 8 Key to exit is displayed You could press the 7 for test Figure 2 72 Screen T est Interface Function Menu Settings Explain Scr Test Run screen test program Key Test Run keyboard test program LED Test Run LED test program ...

Page 85: ...nd knobs and you should also verify that all the backlit buttons illuminate correctly Note When you operate the screen would display the white color LCD The tested button or knobs corresponding area would display green color LCD At the bottom of the screen display Press 8 Key Three Times to exit information is displayed to indicate that pressing 8 three times Is required to exit the test Figure 2 ...

Page 86: ...ys the shapes with two arrows beside them represent the front panel knobs The instructions Press 7 Key to continue Press 8 Key to exit is displayed You could press the 7 button continuously for testing when buttons are lit the corresponding area on the screen would display green color LCD Figure 2 74 Led Test Interface ...

Page 87: ...Utility 1 2 Test Cal SelfCal to enter SelfCal as is shown in Figure 2 5 SelfCal If the environment where the generator is being used changes then it is recommended to do a self calibration Figure 2 75 SelfCal Interface ...

Page 88: ... Boot strap No The times of boot strap Software version Software version of current equipment Hardware version 02 00 00 21 25 represents ordinally PCB version BOM version Daughter card version FPGA version CPLD version Model Contains information of brand of product series bandwidth For example T3AFG5 represents Teledyne Test Tools T3AFG5 10 series function arbitrary waveform generator with 5MHz ba...

Page 89: ...80 Serial No The serial number information includes a date code ...

Page 90: ...ess the Utility button to enter the Utility Menu 3 Press 1 3 option button to enter the third page of Utility Menu 4 Press the Update option button 5 Press Browser option button to select Directory then select the USB Device A through direction key 6 Press Browser option button to select File then select the XXXX ADS file using the direction keys 7 Press the Recall option button to update 8 After ...

Page 91: ...ystem Or you can get help about the operation of the front panel buttons with the help list Press Help to enter the following interface Figure 2 77 Help Menu Figure 2 78 Table 2 37 Help Menu Explanations Function Menu Settings Explanation Cursor upward to select Cursor downward to select Choice Select to read the information ...

Page 92: ...lowing topics Example 1 Generate a Sine Wave Example 2 Generate a Square Wave Example 3 Generate a Ramp Wave Example 4 Generate a Pulse Wave Example 5 Generate a Noise Wave Example 6 Generate an Arbitrary Wave Example 7 Generate a Sweep Wave Example 8 Generate a Burst Wave Example 9 Generate an AM Wave Example 10 Generate a FM Wave Example 11 Generate a PM Wave Example 12 Generate a FSK Wave Examp...

Page 93: ... Input 50 from the keyboard and choose the unit kHz The frequency is set to be 50kHz Set the amplitude 1 Press Ampl to choose Ampl which will display in white color 2 Input 5 from the keyboard and choose the unit Vpp The amplitude is set to be 5Vpp Set the Offset 1 Press Offset to choose Offset which will display in white color 2 Input 1 from the keyboard and choose the unit Vdc The offset is set ...

Page 94: ...85 Figure 3 1 Sine Waveform When the frequency amplitude and offset are set the wave generated is shown in Figure 3 1 ...

Page 95: ... is set to be 5kHz Set the amplitude 1 Press Ampl to choose Ampl which will display in white color 2 Input 2 from the keyboard and choose the unit Vpp The amplitude is set to be 2Vpp Set the offset 1 Press Offset to choose Offset which will display in white color 2 Input 0 from the keyboard and choose the unit Vdc The Offset is set to be 0Vdc Set the duty 1 Press Duty to choose Duty which will dis...

Page 96: ...87 Figure 3 2 Square Waveform When the frequency amplitude offset and duty cycle are set the wave generated is shown in Figure 3 2 ...

Page 97: ... be 10μs Set the amplitude 1 Press Ampl to choose Ampl which will display in white color 2 Input 100 from the keyboard and choose the unit mVpp The amplitude is set to be 100mVpp Set the offset 1 Press Offset to choose Offset which will display in white color 2 Input 20 from the keyboard and choose the unit mVdc The offset is set to be 20mVdc Set the phase 1 Press Phase to choose Phase which will ...

Page 98: ...ymmetry which will display in white color 2 Input 30 from the keyboard and choose the unit 30 The symmetry is set to be 30 When the period amplitude offset phase and symmetry are set the wave generated is shown in Figure 3 3 Figure 3 3 Ramp Waveform ...

Page 99: ...Hz Set the high level 1 Press Ampl and choose the HLevel which will display in white color 2 Input 5 from the keyboard and choose the unit V The high level is set to be 5V Set the low level 1 Press Offset and choose the LLevel which will display in white color 2 Input 1 from the keyboard and choose the unit V The low level is set to be 1V Set the pulse width 1 Press PulWidth and choose PulWidth wh...

Page 100: ...ising Edge which will display in white 2 Input 20 from the keyboard and choose the unit ns The delay is set to be 20ns When the frequency high level low level pulse width and delay are set the wave generated is shown in Figure 3 4 Figure 3 4 Pulse Waveform ...

Page 101: ... Press Noise Stdev 2 Input 10 from the keyboard and choose the unit mV The amplitude is set to be 10 mV Set the mean 1 Press Mean 2 Input 5 from the keyboard and choose the unit mV The offset is set to be 5 mV When the amplitude and offset are set the wave generated is shown in Figure 3 5 Figure 3 5 Noise Waveform ...

Page 102: ...d press Select to enter Arb Main Menu Set the frequency 1 Press Freq and choose Frequency which will display in white 2 Input 5 from the keyboard and choose the unit MHz The frequency is set to be 5MHz Set the amplitude 1 Press Ampl to choose Ampl which will display in white 2 Input 2 from the keyboard and choose the unit Vrms The amplitude is set to be 2Vrms Set the offset 1 Press Offset to choos...

Page 103: ...94 the wave generated is shown in Figure 3 6 Figure 3 6 Sinc Waveform When the arbitrary waveform s type frequency amplitude and offset are set ...

Page 104: ...ich will display in white Input 5 from the keyboard and choose the unit kHz to set the frequency 5kHz 2 Press Ampl to choose Ampl which will display in white Input 5 from the keyboard and choose the unit Vpp to set the amplitude 5Vpp 3 Press Offset to choose Offset which will display in white Input 0 from the keyboard and choose the unit Vdc to set the offset 0Vdc Set the sweep time Press Sweep Sw...

Page 105: ...Input 10 from the keyboard and choose the unit kHz to set stop freq 10kHz Set the Sweep Mode Press 1 2 Linear and choose Linear When all parameters above are set the linear sweep wave generated is shown in Figure 3 7 Figure 3 7 Sweep Waveform ...

Page 106: ...m the keyboard and choose the unit kHz to set the frequency 10kHz 2 Press Ampl to choose Ampl which will display in white Input 1 from the keyboard and choose the unit Vpp to set the amplitude 1Vpp 3 Press Offset to choose Offset which will display in white Input 0 from the keyboard and choose the unit Vdc to set the offset 0Vdc Set the sweep mode Press Burst N Cycle choose N Cycle Mode Set the bu...

Page 107: ...rom the keyboard and choose the unit Cycle to set the burst cycle 5 Set the delay Press Delay and input 100 from the keyboard and choose the unit μs to set the delay 100μs When all parameters above are set the wave generated is shown in Figure 3 8 Figure 3 8 Burst Waveform Output ...

Page 108: ... and choose Ampl which will display in white Input 1 from the keyboard and choose the unit Vpp to set the amplitude 1Vpp 4 Press Offset and choose Offset which will display in white color Input 0 from the keyboard and choose the unit Vdc to set the offset 0Vdc Set the modulation type AM and parameters 1 Press Mod Type AM choose AM Please notice that the message shown on the middle left side of the...

Page 109: ...100 Figure 3 9 AM Waveform When all parameters above are set the wave generated is shown in Figure 3 9 ...

Page 110: ...ss Ampl and choose Ampl which will display in white Input 1 from the keyboard and choose the unit Vpp to set the amplitude 1Vpp 4 Press Offset and choose Offset which will display in white Input 0 from the keyboard and choose the unit Vdc to set the offset 0Vdc Set the modulation type FM and parameters 1 Press Mod Type FM choose FM Please notice that the message shown on the middle left side of th...

Page 111: ...102 3 10 Figure 3 10 FM Waveform When all parameters above are set the wave generated is shown in Figure ...

Page 112: ...mpl and choose Ampl which will display in white Input 5 from the keyboard and choose the unit Vpp to set the amplitude 5Vpp 4 Press Offset and choose Offset which will display in white Input 0 from the keyboard and choose the unit Vdc to set the offset 0Vdc Set the modulation type PM and parameters 1 Press Mod Type PM choose PM Please notice that the message shown on the middle left side of the sc...

Page 113: ...104 Figure 3 11 PM Waveform When all parameters above are set the wave generated is shown in Figure 3 11 ...

Page 114: ...0kHz 3 Press Ampl and choose Ampl which will display in white Input 5 from the keyboard and choose the unit Vpp to set the amplitude 5Vpp 4 Press Offset and choose Offset which will display in white Input 0 from the keyboard and choose the unit Vdc to set the offset 0Vdc Set the modulation type FSK and parameters 1 Press Mod Type FSK choose FSK Please notice that the message shown on the middle le...

Page 115: ...106 Figure 3 12 FSK Waveform When all parameters above are set the wave generated is shown in Figure 3 12 ...

Page 116: ...he unit kHz to set the frequency 5kHz 3 Press Ampl and choose Ampl which will display in white Input 5 from the keyboard and choose the unit Vpp to set the amplitude 5Vpp 4 Press Offset and choose Offset which will display in white color Input 0 from the keyboard and choose the unit Vdc to set the offset 0Vdc Set the modulation type ASK and parameters 1 Press Mod Type ASK choose ASK Please notice ...

Page 117: ...108 Figure 3 13 ASK Waveform When all parameters above are set the wave generated is shown in Figure 3 13 ...

Page 118: ...om the keyboard and choose the unit Vpp to set the amplitude 5Vpp 4 Press Offset and choose Offset which will display in white Input 0 from the keyboard and choose the unit Vdc to set the offset 0Vdc 5 Press PulWidth and choose PulWidth which will display in white Input 40 from the keyboard and choose the unit us to set the PulWidth 40us Set the modulation type PWM and parameters 1 Press Mod Type ...

Page 119: ...110 When all parameters above are set the wave generated is shown in Figure 3 14 Figure 3 14 PWM Waveform ...

Page 120: ...e unit kHz to set the frequency 2kHz 3 Press Ampl and choose Ampl which will display in white Input 4 from the keyboard and choose the unit Vpp to set the amplitude 4Vpp 4 Press Offset and choose Offset which will display in white Input 0 from the keyboard and choose the unit Vdc to set the offset 0Vdc Set the modulation type DSB AM and parameters 1 Press Mod Type DSB AM choose DSB AM Please notic...

Page 121: ...112 Figure 3 15 DSB AM Waveform When all parameters above are set the wave generated is shown in Figure 3 15 ...

Page 122: ...amage or defect or the instrument does not operate properly or fails performance tests notify the Teledyne Test Tools sales representative If the shipping container is damaged or the cushioning materials show signs of stress notify the carrier as well as the Teledyne Test Tools sales department Keep the shipping materials for carrier s inspection 3 Check the accessories Accessories supplied with t...

Page 123: ...turned on 3 After the inspections above restart the waveform generator If the generator still doesn t work after the checking please contact Teledyne Test Tools 2 If there is no signal wave output after setting the parameters please do as following steps 1 Check whether the BNC cable has connected with output channel or not 2 Check whether the output button have been turned on or not ...

Page 124: ...rovide repair or replacement as described in the complete warranty statement To arrange for service or obtain a copy of the complete warranty statement please contact your nearest Teledyne Test Tools sales and service office Except as provided in this summary or the applicable warranty statement Teledyne Test Tools makes no warranty of any kind express or implied including without limitation the i...

Page 125: ...553 2769 Teledyne LeCroy European Headquarters Teledyne LeCroy GmbH Im Breitspiel 11c D 69126 Heidelberg Germany Phone 49 6221 82700 Fax 49 6221 834655 Fax Sales 49 6221 834655 Fax Service 41 22 719 22 99 Email Sales contact gmbh teledynelecroy com Email Service service gmbh teledynelecroy com Email Support applications de teledynelecroy com Web Site http teledynelecroy com germany Phone Service 4...

Page 126: ...pendix A Accessories T3AFG5 10 Series Function Arbitrary Waveform Generator Accessories Standard Accessories A Quick Start A Calibration Certificate A Power Cord that fits the standard of destination country A USB Cable ...

Page 127: ...t from all power sources and clean it with a mid detergent and water Make sure the instrument is completely dry before reconnecting it to a power source To clean the exterior surface perform the following steps 1 Remove loose dust on the outside of the instrument with a lint free cloth Use care to avoid scratching the clear plastic display filter 2 Use a soft cloth dampened with water to clean the...

Page 128: ... portfolio with a comprehensive range of test equipment solutions This new range of products delivers a broad range of quality test solutions that enable engineers to rapidly validate product and design and reduce time to market Designers engineers and educators rely on Teledyne Test Tools solutions to meet their most challenging needs for testing education and electronics validation Location and ...

Reviews: