Model DT9602R 

6000 COUNT AUTO RANGE & AUTO POWER OFF DIGITAL MULTIMETER   

OPERATION MANUAL 

 

         

  This LCD Auto Range & Auto Power off digital multimeter is a portable, compact , 

6000 COUNT    digits with bargraph multimeter . It is ideally suited for field , lab , shop, 
car, and home applications.                                             

 

S

 

afety Information

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Warning

 

To avoid possible electric shock or personal injury, follow these guidelines: 

 Do not use the meter if it is damaged. Before you use the meter, inspect the case. Look for 

cracks or missing plastic. Pay particular attention to the insulation      surrounding the 
connectors. 

 Inspect the test leads for damaged insulation or exposed metal. Check the test leads for 

continuity. Replace damaged test leads before you use the meter. 

The RESPONSIBLE BODY shall be made aware that, if the equipment is used in a manner 

not specified by the manufacturer, the protection provided by the equipment may be impaired. 

 Do not use the meter if it operates abnormally. Protection may be impaired. When in doubt, 

have the meter serviced. 

 Do not operate the meter around explosive gas, vapor, or dust. 

 Do not apply more than the rated voltage, as marked on the meter, between terminals or 

between any terminal and earth ground. 

 Before use, verify the meter’s operation by measuring a known voltage.   

 When measuring current, turn off circuit power before connecting the meter in the circuit. 

Remember to place the meter in series with the circuit. 

 When servicing the meter, use only specified replacement parts. 

 Use caution when working above 30 V ac rms, 42 V peak, or 60 V dc. Such voltages pose a 

shock hazard. 

 

The finger or any part of your body shall not be beyond the barrier of the test probe 

when measuring.

 

 Avoid working alone. 

 When using the probes, keep your fingers behind the finger guards on the probes. 

 Connect the common test lead before you connect the live test lead. When you disconnect 

test leads, disconnect the live test lead first. 

 Remove test leads from the meter before you open the battery door. 

 Do not operate the meter with the battery door or portions of the cover removed or loosened. 

 To avoid false readings, which could lead to possible electric shock or personal injury, 

replace the batteries as soon as the low battery indicator ( 

  ) appears.   

 Use only 

One

 standard 9 volt battery (NEDA 1604, IEC 6F22 or equivalent), properly installed 

in the meter case, to power the meter. 

 To avoid the potential for fire or electrical shock, do not connect the thermocouples to 

electrically live circuits. 

Caution 

To avoid possible damage to the meter or to the equipment under test, follow these guidelines: 

 Disconnect circuit power and discharge all high-voltage capacitors before testing resistance, 

continuity, diodes, or capacitance. 

 Use the proper terminals, function, and range for your measurements. 

 Before measuring current, check the meter’s fuses and turn power OFF to the circuit before 

connecting the meter to the circuit. 

                                                                                               

 

1

Summary of Contents for DT9602R

Page 1: ...circuit Remember to place the meter in series with the circuit When servicing the meter use only specified replacement parts Use caution when working above 30 V ac rms 42 V peak or 60 V dc Such voltag...

Page 2: ...tage is below 7 5V approx Auto Power Off 15 minutes after stopping the switch or no any operation for the press button the meter automatically enters to power off mode Safety standards ETL EMC LVD The...

Page 3: ...nF 4 F 40 F 3 5 400 F 4000 F 20 5 Overload protection 250V DC AC RMS Frequency 9 999Hz 10MHz 0 1 rdg 5 Sensitivity 100kHz 1 5V RMS 100kHz 5V RMS Overload protect 250V RMS Duty Cycle 0 1 99 9 2 rdg 5 O...

Page 4: ...cycle capacitance diode continuity test and temperature measurement 3 Relative Measurement RS232 enable Press this button the meter enter relative measuring state and symbol appear on LCD The result...

Page 5: ...ce measurement 1 Connect the black test lead to COM socket and red test leads to the Ohm socket 2 Set the selector switch to Ohm CAP position and press SELECT button to select resistance measuring mod...

Page 6: ...e of TP 02 thermocouple is 50 700 C 58 1292 F 2 Press SELECT button to switch C or F display 3 Opening the input will display the temperature at the meter terminals by the internal built in sensor 2 1...

Page 7: ...ing new Do not use harsh chemicals cleaning solvents or strong detergents to clean the multimeter 6 Use only fresh batteries of the required size and type Always remove old or weak batteries They can...

Page 8: ...Screw Fuse 0 8A 250V FAST Fuse 10A 250V FAST Fuse Replacement 9602RCk507 2 8...

Reviews: