The Pump Sequencer 132 is designed to provide pump control for either stand-by or 2-stage operation. In stand-by mode, the 132 
automatically switches over from the lead pump to the stand-by pump during a pump failure. In 2-stage mode, the 132 turns on the 
second stage pump to meet additional flow requirements.

Additional functions include:

•  Warm Weather Shut Down (WWSD)
• Exercising
•  Equal Run Time Rotation
•  Alert per Pump or Alert Levels

•  Adjustable flow proof delay
•  Test sequence to ensure proper component operation
•  120 V (ac) power supply
•  CSA C US certified (approved to applicable UL standards)

Input

Outdoor

Sensor

Optional

Output

Pump

Pump

Input

120 V (ac) Power

Supply

Input

Pump

 

Demand

Signal

       US

Made in Canada by

tekmar Control Systems Ltd.

Power:

Pump Relays:

Alert Relays:

Demands:

120 V  ± 10% 60 Hz 6 

    VA

240 V (ac) 10 A 1/2 hp, pilot duty 720 VA

240 V (ac) 10 A 1/3 hp, pilot duty 240 VA 

20 to 260 V (ac) 2 VA 

Signal wiring

must be rate d

at least 300   V.

H1

197E

Test

1

2

Pump

Demand

3

4

2-Stage

Demand

5

6

Flow

Proof

8

9 10 11

12

1

1

2

7

17 18

Outdoor

Sensor

Pump

2

Clear  Alert

Pump 1

Pump 2

Alert A 

Alert B 

Flow Proof

2-Stage Demand

Pump Demand

WWSD

Power

WWSD

35

Off

70°F

100

Frequency of Rotation

12

Off

96 hours

168

not testing

testing

testing paused

off

red

red

13 14

Alert

15 16

Alert

A

A

B

B

Input

2-Stage

Demand

Signal

Output

Do not apply power

Output

Alert

Output

Alert

2-Stage

Alert Levels

Pum p

1  2

Auto

30 second Delay

Exercising

Alert per Pump

Off

10 second Delay

Off

Stand-by

Pump Sequencer 132

Stand-by / 2-Stage

Input

Flow Proof

Signal

48

144

Use supply wires suitable for

120°F (50°C) above ambient

Pump

N

L

Power

Meets Class B
Canadian ICES
FCC Part 15

 

 

Note: 

Pump demand must
be powered with 20 to
260 V (ac)  before the
pump will turn on.

Содержание Pump Sequencer 132

Страница 1: ...ms Ltd Power Pump Relays Alert Relays Demands 120 V 10 60 Hz 6VA 240 V ac 10 A 1 2 hp pilot duty 720 VA 240 V ac 10 A 1 3 hp pilot duty 240 VA 20 to 260 V ac 2 VA Signal wiring must be rated at least...

Страница 2: ...econds then the control turns on all of the red LED s for 2 seconds After this test the control enters its normal operating mode When the control is powered up the Power light remains on continuously...

Страница 3: ...trol turns on the output for 10 seconds This minimizes the possibility of a pump seizing during a long period of inactivity Note The exercising function does not work if power to the control or pumps...

Страница 4: ...ts have two modes of operation The mode of operation for the alert contacts is selected using the Alert per Pump Alert Levels DIP switch When an alert contact is activated refer to the Error Messages...

Страница 5: ...check the wiring diagram and select those sections of the chamber with common voltages Do not allow the wiring to cross between sections as the wires will interfere with safety dividers which should b...

Страница 6: ...als 17 and 18 The outdoor sensor is used by the 132 to measure the outdoor air temperature Note If an outdoor sensor is not installed the WWSD dial must be set to Off STEP FIVE TESTING THE WIRING Each...

Страница 7: ...is off you should measure less than 5 V ac Test The Outputs Pump 1 and Pump 2 Make sure power to the terminal block is off and install a jumper between Pump 1 terminals 7 and 8 When the pump circuit...

Страница 8: ...to section A 30 second Delay 10 second Delay The 30 second Delay 10 second Delay DIP switch is used to select what time delay is required to prove flow once a pump contact is turned on Refer to sectio...

Страница 9: ...ter 10 seconds the Alert A contact is shut off Step 4 Alert B contact is turned on for 10 seconds After 10 seconds the Alert B contact is shut off ERROR HANDLING If an internal control fault occurs th...

Страница 10: ...or Short Control Internal Error Outdoor Sensor Open WWSD Off Flow Proof Signal Pump 1 Failed Pump 2 Failed Pump 1 and Pump 2 Failed Power WWSD 2 Stage Demand Flow Proof Pump Demand Power WWSD 2 Stage...

Страница 11: ...11 of 12 2010 D 132 04 10 Notes...

Страница 12: ...PTION OF THE PRODUCT ITS NON INFRINGEMENT OF ANY RELEVANT PATENTS OR TRADEMARKS AND ITS COMPLIANCE WITH OR NON VIOLATION OF ANY APPLICABLE ENVIRONMENTAL HEALTH OR SAFETY LEGISLATION THE TERM OF ANY OT...

Отзывы: