BRACKET PRO SERIE
®
152
USER GUIDE
Страница 1: ...BRACKET PRO SERIE 152 USER GUIDE ...
Страница 2: ...ith Smiths Medical Smiths Medical does not promote or sell Technimount products In order to ensure continuous improvements to our products and services we invite you to communicate your comments to our Customer Service Department at customerservice technimount com LEGAL NOTICE Technologies CGC Inc or Technimount E M S Holding Inc or its affiliates are not expressly associated with the marketing di...
Страница 3: ...our Technimount product its components or for any technical questions during the installation or maintenance processes please send an email to techsupport technimount com Please have the serial number of your Technimount product available as shown in the figure below when calling Technimount Technical Support Include the serial number in all written communications SERIAL NUMBER LOCATION CONTACT IN...
Страница 4: ...ution Note 12 NOTICE CERTIFICATION 14 INSTALLATION GUIDE 15 Removing the Packaging for Installation 15 Tools Required for Installation 15 Identification of Components 16 Front Support Plate 16 Hardware Kit 16 Installation of the Bracket onto the Medfusion 4000 Syringe Pump 17 MAINTENANCE GUIDE 19 Cleaning 19 Cleaning Process 19 Removal of Iodine Compounds 20 Preventive Maintenance 20 Inspection Pr...
Страница 5: ...LE OF CONTENT RETURN POLICY 26 Return Policy 26 Prior to 30 Days 26 Prior 45 Days 26 Prior 60 Days 26 Return Authorization 26 Damaged Merchandise 27 Claim Process 27 Required Information 27 Findings and Conclusion 27 Questions about our Policy 27 ...
Страница 6: ... 6 BP152 UG 202108 01 www technimount com INTRODUCTION SYMBOLS AND DEFINITIONS SYMBOL DESCRIPTION Warning and Caution special attention is required Consult accompanying documents Safe working load symbol and Load balance symbol ...
Страница 7: ... in death or serious injury It may also describe potential serious adverse reactions and safety hazards Caution Alerts the reader of a potentially hazardous situation which if not avoided may result in minor or moderate injury to the user or patient or damage to the equipment or other property This includes special care necessary for the safe and effective use of the device to avoid damage that ma...
Страница 8: ...UG 202108 01 www technimount com PRODUCT ILLUSTRATION BRACKET PRO SERIE 152 Front View INTRODUCTION Top Support Block to Secure Medical Device Front Support Plate to Secure Medical Device High Density Aluminum with Black Anodized Finish ...
Страница 9: ...rn to Table of Content PRODUCT ILLUSTRATION CONTINUED BRACKET PRO SERIE 152 SUITE Back View INTRODUCTION Rubber Cusions Inside the Bracket to Protect the Medical Device Anti Rotation Micro Disc for Installation on Vertical and Wall Mounting Systems ...
Страница 10: ...nimount has designed a system to attach and install medical equipment owned by the customer on an incubator transport stretcher manufactured by Stryker and involving or not a Dräger or other incubator brand The purchase and use of products designed by Technimount are subject to this limitation of liability clause It is important to understand that as Technimount is not the manufacturer of the Stry...
Страница 11: ... Installation Device Retained on Main Assembly with support blocks Attachment Options Anti Rotation Micro Disc Transportation Compatibility System Compatible with Technimount s Safety MD Transporter vertical Vertical Mounting System Micro Base Features Access to all Medical Device Monitors Connectors and Accessories Rubber Cushions Inside the Bracket to Protect the Medical Device Anti Rotation Mic...
Страница 12: ...perly the medical device could fall during transport and may cause injury to the patient or operator and or damage to the product 9 Do not allow untrained staff to assist in the operation of the mounting system Untrained technicians staff can cause injury to the patient or themselves 9 Do not place additional equipment or items onto the bracket or mounts other than approved Technimount or componen...
Страница 13: ...osive residue on the surface possibly causing premature corrosion of critical components 9 When ordering it is important to identify on which mounting system you need to mount the bracket on as there are different systems for different applications ground 9 A maintenance program should be established for all Technimount equipment Preventive maintenance may need to be performed more frequently base...
Страница 14: ...ount com WARNING The end user and administrator are responsible to validate regulations and standards for safety in their region in order to comply with applicable safety regulations Technimount is not responsible to inform the end user and or administrator of applicable legislation for safety in their area LEGAL NOTICE The purchase and use of products designed by Technimount are subject to this l...
Страница 15: ...ed TOOLS REQUIRED FOR INSTALLATION Below are the basic tools required for installation Other tools may also be required If you have any questions regarding the installation or need assistance please contact our Technical Support team at techsupport technimount com 9 Phillips Screwdriver NOTE 9 Electrical tools are not recommended as there is a potential risk of damage to the threads 9 Technimount ...
Страница 16: ...PLATE The Black Anodized Finish Aluminum support plate is used for the installation of the Syringe Infusion Pump Medfusion 4000 It allows to secure the medical device HARDWARE KIT Thefollowinghardwareisprovidedfortheinstallation of the Bracket Pro Serie 152 9 Four 4 Black Oxide Stainless Steel Round Head Phillips Screws 10 32 x 3 8 ...
Страница 17: ...ro Serie 152 is designed to be installed on the Medfusion 4000 Syringe Infusion Pump from Smiths Medical 2 Install the main assembly on a stable surface 3 Align the medical device with the main assembly INSTALLATION GUIDE INSTALLATION OF THE BRACKET ONTO THE MEDFUSION 4000 SYRINGE PUMP ...
Страница 18: ...ate 7 Press the front support plate against the medical device to secure it into the assembly NOTE Put a few drops of medium strength thread locking adhesive blue Loctite 242 on each screw before installation to prevent the screws from loosening during normal use 8 Tighten the four 4 screws CAUTION 9 Do not use electrical tools to install the screws 9 Do not overtighten the screws 9 The Medfusion ...
Страница 19: ...iscoloration from continuous washing however degradation of the product s performance or functionality will not be affected due to power washing if cleaning instructions are properly followed The material used to manufacture the bracket is high grade aluminum it is very durable and resistant to corrosion however high levels of sodium or a high concentration of sodium or acid may prematurely corrod...
Страница 20: ... the product we recommend sanding the affected surface to remove the rust and then using the cleaning method presented in this guide once the rust is removed To clean the stained area use a solution of 1 4 Tablespoon of Sodium Thiosulfate in 1 pint 5 litre of warm water to clean the stained area Clean as soon as possible after staining occurs If stains are not immediately removed allow solution to...
Страница 21: ...erform these inspections please contact your Technical Support Team at techsupport technimount com Check each routine and replace damaged or worn out parts if necessary Follow timetable below for maintenance either in months M or hours H in accordance with your Service s current maintenance practices and protocols ITEM ROUTINE 1 M OR 2 H 3 M OR 6 H 6 M OR 12 H 12 M OR 24 H Bracket 9 Inspect the br...
Страница 22: ...Return to Table of Content 22 BP152 UG 202108 01 www technimount com MAINTENANCE GUIDE INSPECTION AND MAINTENANCE RECORD PREVENTIVE MAINTENANCE PERFORMED BY DATE TIME ...
Страница 23: ...www technimount com BP152 UG 202108 01s 23 Return to Table of Content MAINTENANCE GUIDE TRAINING RECORD DATE TRAINING METHOD TRAINEE NAME BASIC TRAINING TRAINING UPDATE ...
Страница 24: ...fied on the assembly drawing parts in this user guide may not be individually available for purchase Please call Technimount Customer Service 1 888 639 2758 or at customerservice technimount com for availability and pricing DESCRIPTION PART NUMBER Bracket Pro Serie 152 2100 10 SMMF 4 Four 4 Black Oxide Stainless Steel Round Head Phillips Screws 10 32 x 3 8 TCM VF 999 187 Front Support Plate TCM 09...
Страница 25: ...laced after the Warranty Period has expired the Warranty Period for the repair or replacement will expire three 3 months after the date of repair or replacement LIMITED RESPONSIBILITY AND WARRANTY The Limited Warranty does not apply to normal wear that should result from normal use It does not apply when the Hardware or any component is opened disassembled or repaired by someone not authorized by ...
Страница 26: ... 45 DAYS Product must be unused undamaged and in its original packaging The product return request must be provided in writing and it must be approved by TECHNIMOUNT prior to returning the product Returns will not be approved on modified or damaged item Charges may apply if damaged or missing items Customer is responsible for a 25 restocking fee PRIOR 60 DAYS Product must be unused undamaged and i...
Страница 27: ... the RMA form online at https www technimount com service support service support overview REQUIRED INFORMATION Serial number Invoice number Identification of the issue Upload the pictures of the issue Submit the form A confirmation of the receipt of the claim will be sent to you within 2 business days If you have not received a confirmation email by then please contact techsupport technimount com...
Страница 28: ...t matters most Technimount E M S Holding Inc 3770 Jean Marchand Street Suite 100 C Quebec QC G2C 1Y6 Canada T 1 888 639 2758 F 1 855 339 6351 technimount com info technimount com 2021 Technimount E M S Holding Inc All Rights Reserved Printed in Canada ...