background image

TCS TürControlSysteme AG

 

Subject to technical changes. 

Mail: [email protected]

 

PI_IMM2300_Art0031160-uk.doc 

 

 

Product information 

 

Video indoor station for  

hands-free talking 

IMM2300 

 

 

Summary of Contents for IMM2300

Page 1: ...TCS TürControlSysteme AG Subject to technical changes Mail info tcsag de PI_IMM2300_Art0031160 uk doc Product information Video indoor station for hands free talking IMM2300 ...

Page 2: ...dule 7 Mounting and installation 8 Installing the lower cover 8 Without flush mounted socket 8 Connection of cables 9 Connect the device 9 Connect the video module 9 Terminating resistor 9 Snapping on the upper cover of the modules 10 Open the device 10 Note on power supply 11 Wiring example 11 Connection diagram 11 Commissioning 12 Settings 12 Factory settings 12 Preset times 12 AS address depend...

Page 3: ...on systems according to VDE 0800 must be observed separated cabling for heavy and low current lines minimum distance of 10 cm for common cablings use of separators between heavy and low current lines in shared cable ducts use of standard telecommunication lines e g J Y St Y with 0 8 mm diameter existing lines modernisation with deviating cross sections can be used in compliance of the loop resista...

Page 4: ...ons can be connected polarity free a b within one system polarity free only in 6 wire operation For this a suitable power supply and control unit has to be used Table 1 loop resistances cable length a b M P in m cable diameter 0 6 mm 0 8 mm loop resistance in Ω 10 1 22 0 69 20 2 45 1 38 30 3 67 2 07 40 4 90 2 76 50 6 12 3 44 60 7 35 4 13 70 4 82 80 5 51 90 6 20 100 6 89 Principle loop resistance M...

Page 5: ...degree of protection IP 40 input current standby 3 wire operation I a 0 5 mA I P 4 7 mA max input current I Pmax 155 mA video module TFT color module screen diagonal 2 4 inch resolution 480 x 234 pixel video signal entrance symmetrical 1 Vss FBAS Only video 6 wire technique possible display call OFF red display additiona functions green door release button function key light switch button call OFF...

Page 6: ...internal call to the indoor station door release automatic call diversion ring tone selection internal call call from the indoor sta tion light switch button switching lights ring tone selection floor call call from the flat door call OFF button ring tone OFF button end communication initiating and ending the programming and ring tone selection ring tone volume control ring tone volume continuousl...

Page 7: ...stic call distinction between 2 doors flat door and internal call ring tone volume can be adjusted manually volume for internal communication adjusta ble ring tone mute with optical display optical display of door calls optical display of a busy line when communication is established automatic hands free talking after internal call can be activated one parallel call can be activated sending of the...

Page 8: ... only Installing the lower cover Without flush mounted socket Install the lower cover at the at tachement holes with suitable screws on the wall as shown in the illustration lower cover With flush mounted socket Position the flush mounted sock et behind the cable gland Install the lower cover at the at tachement holes with suitable screws on the wall as shown in the illustration position flush mou...

Page 9: ...er Connecting the device Connect the lines according to the label ling Connecting the video module Connect the prepared video lines to the pluggable screw terminals in the acces sories and plug them to the tripled pin header see illustration at the printed circuit board of the video module Pay attention that V1 and V2 are con nected correctly Make sure that the plug terminal is plugged in accordan...

Page 10: ...over on both locking brackets at the lower cover 1 Lock the upper cover in place 2 Opening the device 1 There are rectangular release openings at the underside of the device for every module Insert a screwdriver around 7 mm with slight pressure straight into this opening 2 The upper covers can be re moved at the underside 3 Lift the upper cover of both upper locking brackets ...

Page 11: ...0031160 uk doc Notice on the power supply In case of power supply with BVS20 or BVS100 additionally use NGV1011 Wiring example Connection diagram J1 must be plugged if the device is installed at the end of a TCS BUS video strand Remove J1 if the device is not installed at the end of a TCS BUS video strand ...

Page 12: ... x flashing internal standby time around 2 min if the device was called around 30 sec if the device is calling and waiting for call acceptance AS address dependent image activation If there are not only video front door stations but also front door stations without camera within one system the image is not activated when a call arrives from these front door stations In order to guarantee this func...

Page 13: ...e volume control clockwise to in crease the volume Programming the basic module Manual programming Legend for programming The programming takes always place in four steps 1 2 3 4 Initiate the programming Preselection Final selection End the programming 1 Initiate the programming press call OFF button 8 sec until release a short acknowledgement tone sounds ...

Page 14: ...nd green LED goes out door release automatic call diversion Note Before programming the call diversion the AS address of the front door station is to be set and blocked with the Service Device to be executed at the destined indoor station press speech button lift handset or internal call at function key to be executed at the destined indoor station press speech button lift handset or control funct...

Page 15: ...lel call Note Deactivate the function with programming func tion reload factory set ting to be executed at the destined indoor station 1 press speech button lift handset or switch off parallel call block ring tone selection block manual programming lift pogramming lock Attention First switch on the BVS programming mode of the system Carry out the steps 1 to 4 Switch off program ming mode of the sy...

Page 16: ...k doc 4 End the programming Press call OFF button short or automatically if no button is pressed for more than 8 sec Programming with the Service Device TCSK 01 For further information see TCS Installer 7 Service Device TCSK 01 or programming handbook TCSK 01 searching telephones parallel call ParS No Ser No ...

Page 17: ...b select ring tone from second front door sta tion if existing Then press the speech button until the desired ring tone sounds The ring tone selected last will be stored 2c select ring tone from floor door Press the light switch button until the desired ring tone sounds The ring tone selected last will be stored 2d select internal ring to ne Press the function key until the desired ring tone sound...

Page 18: ...htness control of the station is set too high Turn down the brightness control at the station The level of the video signal is too high Turn down the level of the video BUS e g rotary switch at the board of the camera Is only working if the terminating resis tance at the station or active ex tended functions e g FVY is set correctly The terminating resistor at the end of the strand is not plugged ...

Page 19: ... compo nents to one potential Insert a coupling element into the video BUS in order to electrically insolate it Please contact our technical dis tribution in order to get these ac cessories Distorted image No accurate video signal due to interchanged video wires The video BUS is not reverse polarity protected Please change the wires V1 and V2 The image rolls The video signal cannot be syn chronise...

Page 20: ...e video image turns white after a while When switching the supply voltage off and on again the signal will reappear After a while the video image turns white again Thermal defect of the outdoor cam era The V1 of the video BUS short circuits the P or b wire This causes an impossible increased current Please check the wiring for short circuits The camera is defect Cleaning Avoid water entering the d...

Reviews: