background image

©2014 – 2023 Twin City Fan Companies, Ltd.

Contents

Introduction....................................................................................1 

Shipping and Receiving ..................................................................1 

Handling .........................................................................................2 

Short Term Storage .........................................................................2

Long Term Storage ..........................................................................2 

Foundations and Supporting Structures ........................................2 

Fan Installation ...............................................................................3 

Assembly of Fans ............................................................................3

Electrical Wiring of Fans .................................................................4 

Fan Operation – Safety ...................................................................4 

Operation Checklist ........................................................................4

Maintenance of Fans ......................................................................5 

    General Motor Maintenance.....................................................5 

    Impeller and Shaft Maintenance ...............................................5 

  Structural Maintenance .............................................................5 

Troubleshooting Guidelines ...........................................................5

Troubleshooting Performance Problems

    Air Capacity Problems ...............................................................5

  Noise Problems .........................................................................5

  Vibration Problems ....................................................................5 

  Motor Problems ........................................................................6 

Limitation of Warranties and Claims ..............................................6

Introduction

The purpose of this manual is to provide instructions that complement 

good general practices when installing or operating fans manufactured 

by Twin City Fan & Blower. It is the responsibility of the purchaser to 

provide qualified personnel experienced in the installation, operation 

and maintenance of air moving equipment.

Instructions given in the body of this manual are general in nature and 

apply to a variety of models manufactured by Twin City Fan & Blower. 

Most units can be installed and maintained with the instructions given. 

Additional product and engineering information is available at www.tcf.

com.

Special applications may require additional information. These 

instructions are supplied in the form of attached appendices. Use the 

instructions in the appendix if the directions in this manual differ from 

instructions in the appendix.

As always, follow good safety practices when installing, maintaining and 

operating your air moving equipment. A variety of safety devices are 

available. It is the user’s responsibility to determine adequate safety 

measures and to obtain the required safety equipment.

Shipping and Receiving

All Twin City Fan & Blower products are carefully constructed and 

inspected before shipment to insure the highest standards of quality 

and performance.

Compare all components with the bill of lading or packing list to verify 

that the proper unit was received.

Check each unit for any damage that may have occurred in transit. 

Any damage should be reported immediately to the carrier and the 

necessary damage report filed.

Figure 1.  Lifting Lug Locations

DETAIL  

SCALE 1 : 2

NOTE: 

When lifting, the straps/

chains should be at a minimum 

angle of 45°

Throughout this manual, there are a number of HAZARD WARNINGS that must be read and adhered to in order to prevent possible 

personal injury and/or damage to equipment. Two signal words "WARNING" and "CAUTION" are used to indicate the severity of a hazard 

and are preceded by the safety alert symbol.

 

WARNING

Used when serious injury or death MAY result from misuse or failure to follow specific instructions.

 

CAUTION

Used when minor or moderate injury or product / equipment damage MAY result from misuse or failure to follow specific instructions.

NOTICE

Indicates information considered important, but not hazard-related.

It is the responsibility of all personnel involved in installation, operation and maintenance to fully understand the   

 

   

     Warning and 

Caution procedures by which hazards are to be avoided.

Twin City Fan

IM-495

April 2023

Modular Plenum Fans 

(MPLFN, MPLFS, MPLQN, MPLQS)

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Summary of Contents for MPLFN

Page 1: ...talling maintaining and operating your air moving equipment A variety of safety devices are available It is the user s responsibility to determine adequate safety measures and to obtain the required s...

Page 2: ...d in the motor and fan bearings The fan impeller should be left at approximately 180 degrees from that of the previous month to prevent the shaft and impeller from taking a set in one position Storage...

Page 3: ...ow proper handling instructions given earlier 1 Move the fan to the final mounting position 2 Remove skid crates and packing materials carefully 3 If supplied place vibration pads or isolation base on...

Page 4: ...power of the fan while service is in process Operation Check List Check fan mechanism components System connections are properly made and tightened Bearings are properly lubricated Impeller drives and...

Page 5: ...onents for corrosion cracks or other signs of stress Concrete should be checked to ensure the structural integrity of the foundation Troubleshooting Guidelines Use current safety practices when invest...

Page 6: ...and material under normal use and service except in those cases where the materials are supplied by the buyer for a period of one year from the date of original installation or eighteen 18 months from...

Page 7: ...Twin City Fan Blower Installation and Maintenance Manual IM 495 7 Twin City Fan...

Page 8: ...BLOWER WWW TCF COM 5959 Trenton Lane N Minneapolis MN 55442 Phone 763 551 7600 Fax 763 551 7601 Twin City Fan Visit www tcf com to view all of Twin City Fan Blower s Installation Manuals and Fan Engin...

Reviews: