INSTALLATION INSTRUCTIONS

 

THIS FAUCET MEETS OR EXCEEDS THE FOLLOWING STANDARDS: 

cUPC, ASME A112.18.1, NSF-61 AND LOW LEAD COMPLIANT

Your installation may require new supply 
lines. (Supply lines are not included.)

CUSTOMER SERVICE

      WEST 1-800-267-4774   |   EAST 1-800-387-7064   |   

taymor.com

® REGISTERED TRADEMARK OF TAYMOR INDUSTRIES LTD.

TURN OFF

TURN OFF

B

E

E

C

F

A

A

F

G

H

A

B

D

C

S

IL

IC

ON

E

B

SI

LI

CO

N

E

2

3

1

THANK YOU

 FOR PURCHASING THIS TAYMOR PRODUCT. ALL TAYMOR PRODUCTS ARE  CAREFULLY

ENGINEERED AND FACTORY TESTED TO PROVIDE LONG TROUBLE-FREE USE UNDER NORMAL CONDITIONS.

HAVE BASIC TOOLS READY

RECOMMENDED TOOLS:

1

Flashlight

Teflon tape Screwdrivers

Adjustable and

Pipe wrench

Plumber’s putty

Safety goggles

Torque wrench

Silicone caulk

4

ATTACH THE HOT AND COLD SUPPLY LINES

Apply teflon tape onto threaded ends of faucet inlets.
Connect  water supply lines to faucet inlets. Hot water supply lines go into left inlet. Cold water supply  
lines go into right inlet. (Supply lines are not included.)

FOR BRAIDED PLASTIC AND BRAIDED 

 STAINLESS STEEL SUPPLY TUBES

FOR 3/8” O.D. BALL-NOSE SUPPLY TUBES

IF THE SUPPLY 

TUBE END HAS A 

BULBOUS SHAPE,  

USE THE SUPPLIED 

COUPLING NUTS.

THESE SUPPLY 

TUBES HAVE

INTEGRAL NUTS, 

SO JUST SCREW 

THE NUT ONTO 

THE FAUCET 

INLET.

5

INSTALLING POP-UP DRAIN

A)

 Remove pop-up plunger (A) and flange (B). Screw locknut (C) all the way down. Push 

gasket (D) down. Apply silicone to underside of flange (B).

B) 

Insert body into sink (from underneath). Screw flange onto body. Pivot hole (E) must face    

  the back of the sink.

C)

 Tighten locknut (C) and gasket but do not overtighten. Remove pivot ball retaining nut (E).

D) 

Slide pivot rod (F) into the eye of the pop-up plunger (A). Hand tighten retaining nut.

E)

 Slide pivot rod (F) through hole in spring clip (G), then through lever strap (H) and back  

 

  through spring clip

.

 

F)

 Insert lift rod (I) down through faucet body and then into lever strap (H). Tighten screw (J).   

  Connect assembly to drain.

TORQUE
22 – 30 FT/LBS.

TORQUE
22 – 30 FT/LBS.

3

FAUCET INSTALLATION

A)

 Install spout on seat and through the center mounting hole of the sink or countertop. From 

underneath the sink secure the spout with rubber washer, metal washer and nut.

B)

 Ensure the handle seats and the handles are aligned as in diagram (2) by turning the handle seat if 

necessary (1), the open-close turn of the handle cannot exceed 90°.  Slide hot and cold end valves 

through sink mounting holes. Make sure the valve for “Hot” is placed on the left  hand side and long 

inlet tubes are installed away from spout. 

Note: Hot side end valve is labeled

. Secure end valves 

with washers and nuts. Hand tighten nuts onto shank. Lock nuts into position by tightening screws.

C) 

Align tabs (1) and (2) on quick connects (3). Push quick connect housing firmly upward and snap onto 

receiving tube tab. Pull down moderately to ensure connection has been made. If it is necessary to 

remove quick connect, squeeze tabs on hose between index finger and thumb, then pull down to 

disconnect.

Don’t use plumber’s putty on cultured marble or other composite sinks. 
Putty will discolour the sink.

2

TURN OFF THE MAIN WATER SUPPLY

Locate water supply inlets and shut off water supply valves. These are usually found under 
the sink.

WARNING: READ ALL

 the instructions completely before beginning.  

READ ALL

 warnings, care and maintenance information.

Taymor recommends calling a professional if you are uncertain about installing this product!

This product should be installed in accordance with all local and provincial plumbing and building codes.

Use only a  damp cloth to clean and shine, then dry with a soft cloth. Avoid abrasive cleansers, bleach 

solvents, steel or bronze wool or other chemicals which may cause damage. A finish deterioration occurring 

from use of paints, solvents, cleaners, or other chemicals is not a defect and therefore is not covered by the 

warranty.

Need Help?

 Please call our toll-free Customer Support line at 

(WEST) 1-800-267-4774     (EAST ) 1-800-387-7064 for additional assistance or service.

A

B

1

2

3

2

1

C

DIXON 06-4037P

TWO HANDLE LAVATORY FAUCET

6

7

EXPLODED DIAGRAM FOR REFERENCE 

MAINTENANCE

 Your new faucet is designed for years of trouble-free performance. Keep it 

looking new by cleaning it periodically with a soft cloth. Avoid abrasive cleaners, steel
wool and harsh chemicals as these will dull the finish and void your warranty.

FLUSHING & AERATOR CLEANING

Remove the aerator by turning it counterclockwise 
with the plastic wrench provided.. Remove the 
internal parts of the aerator by pushing them out 
with your fingers. Remove any debris. Turn on hot 
and cold water supplies. Turn faucet handles all the 
way on and run water through the spout for about a 
minute to remove debris. While water is running check all connections for leaks. 
Reassemble the aerator and screw it back into the spout hand tight.

24 - HANDLE

1 - SPOUT

2 - O-RING

4 - TUBE

5 - BOLT

3 - WASHER

6 - WASHER

7 - NUT

8 - HOSE

9 - POP-UP

10 - O-RING

11 - BLOCK

12 - SCREW

13 - NUT

14 - WASHER

15 - BODY

16 - SEAT

17 - WASHER

18 - FLANGE

19 - CARTRIDGE

20 - BONNET

21 - O-RING

22 - HANDLE SET

23 - CLIP

25 - AERATOR

26 - WRENCH

Reviews: