background image

Type No.

86010148

V01

Protocols

compliant to AISG 1.1 and 3GPP/AISG 2.0

Logical interface ex factory

1)

3GPP/AISG 2.0

Input voltage range

V

10 ... 30 (pin 1, pin 6)

Power consumption

W

< 1 (stand by); < 10 (motor activated)

Connectors

2)3)

2 x 8 pin connector according to IEC 60130-9; according to AISG

Daisy chain in: male; Daisy chain out: female

Hardware interfaces

RS 485A/B (pin 5, pin 3);

power supply (pin 1, pin 6); DC return (pin 7);

according to AISG / 3GPP

Adjustment time (full range)

sec

40 (typically, depending on antenna type)

Adjustment cycles

> 50,000

Temperature range

°C

–40 … +60

Protection class

IP 24

Lightning protection

AISG interface (each pin)

2.5 kA (10/350 μs)

8 kA (8/20 μs)

Housing material

Profile: Aluminum anodized; cover: Aluminum die cast coated

Weight

kg

Ibs

0.5

0.99

Packing size

mm

inches

245 x 93 x 102

9.6 x 3.6 x 4

Dimensions (H x W x D)

mm

inches

177.5 x 59.5 x 49.5

7.0 x 2.3 x 1.9

1)

The protocol of the logical interface can be switched from 3GPP/AISG 2.0 AISG 1.1 to with a vendor
specific command. Start-up operation of the RCU is only possible in a RET system supporting 3GPP/
AISG 2.0!
The protocol can also be changed as follows: 3GPP to AISG 1.1: Enter “AISG1” into the additional data
field “Installer’s ID” and perform a layer 2 reset or a power reset. AISG 1.1 to 3 GPP: Enter “3GPP” into
the additional data filed “Installer’s ID” and perform a layer 7 reset or a power reset. After switching the
protocol any other information can be entered into the “Installer’s ID” field.

Please note:

If the Primary of the RET system doesn’t support the standard of the ‘logical interface ex factory’, the RCU
must be switched to the appropriate standard of the Primary before installation. Please contact Kathrein for
further information.

2)

The tightening torque for fixing the connector must be 0.5 – 1.0 Nm. The connector should be tightened
by hand or using the torque screwdriver (85010080)as described in the connecting cable data sheet
(85010007, ...)

3)

The RCU gets the information stored in the antenna after power on automatically if a corresponding
antenna is used. In this case, it is not necessary to configurate the RCU manually.

Standards:

EN 60950-1 (Safety)
EN 60950-22 (Safety – Equipment installed outdoor)
EN 55022 (Emission)
EN 55024 (Immunity)
ETS 300019-1-4 (Environmental)
UL 60950-1; 1

st

edition

Certification:

CE, FCC

Scope of supply:

Remote Control Unit
Assembly paste

86010148

V01

Page 1 of 5

9

3

6

.4

6

2

4

/e

S

u

b

je

c

t

to

a

lt

e

ra

ti

o

n

.

Remote Control Unit (RCU)

Remote Control Unit (RCU)for Kathrein base station antennas with adjustable electrical down-tilt
and appropriate mechanical interface.

Compliant to AISG 1.1 and 3GPP/AISG 2.0

Questions? Visit www.Talleycom.com or contact Talley at 800.949.7079 or [email protected] today.

Daisy Chain feasibility

Compact size

Suitable for operation under outdoor conditions

Prepared for automatic configuration and calibration

173.6 | 6.8

33.2 | 1.27

M

4

2

x

1

.5

2

8

.5

|

1

.1

4

6

|

1

.8

5

9

.5

|

2

.3

4

49.5 | 1.95

8 | 0.31

All dimensions in mm | inches

Daisy chain in
(male)

Daisy chain out
(female)

Bottom view of RCU

All specifications are subject to change without notice.

Reviews: