Summary of Contents for 860000

Page 1: ...8 SETUP MENU 10 9 STANDARD APPS 15 11 SYSTEM UPDATE 18 12 LICENSE ACTIVATION 20 13 TECHNICAL SPECIFICATIONS 21 14 PC REQUIREMENTS 23 15 MAINTENANCE 24 16 WARRANTY 24 18 ERGONOMIC RECOMMENDATIONS 24 19 DECLARATION OF CONFORMITY 25 20 COMPLIANCE STATEMENTS 26 MANUAL TAGARNO FHD PRESTIGE Go to tagarno com productmanuals to find manuals and tutorial videos ...

Page 2: ...lways turn off the system before unplugging when possible WARNINGS The product is a digital magnifying system consisting of a camera unit PCBs mechanical parts and a power supply The product is intended for marketing worldwide and is designed for manual visual inspection INTENDED USE Read all safety information before you use the product Please pay attention when you see a warning label on the pro...

Page 3: ...iffusor lens kit Fresnel lens kit 100 mm for Lens 1x Plan 4 YOU HAVE RECEIVED Smart guide Camera arm with lens Base Rod washers screw OPTIONS XPLUS FHD control box Power supply USB A B 3 0 cable Hex keys x 3 HDMI HDMI cable USB memory stick Lights control box Polarizer kit ...

Page 4: ...ally and horizontally on top of the base Fasten the two washers with the screw on top of the rod Pull the release button and place the camera arm on the rod The complete microscope with base 5 ASSEMBLING TIP Find the How to Install tutorial video here www tagarno com installprestige ...

Page 5: ...ntrol box Output 3 3V 6A Max Use only control boxes supplied by TAGARNO 4 Output HDMI Standard Type A Monitor HDMI Out 1080p60 5 Ethernet RJ 45 Ethernet wall socket Ethernet LAN 100BASE TX 1000BASE T 6 USB 3 0 output USB 3 0 Type B Socket Computer USB 3 0 Device Self powered 7 ESD Snap Socket 10mm ESD Grounding point ESD Grounding point Only black models 8 Power supply DC DC Jack Power socket Inpu...

Page 6: ... Power on off Place the camera arm in the appropriate height according to the lens you are using Adjust the friction according to your personal preference 7 OPERATION TIP Find the How to Use tutorial video here www tagarno com useprestige ...

Page 7: ...you wish to focus on something very close Push this button on the control box to adjust focus if you wish to focus on something that is farther away To turn the autofocus on again simply push both zoom buttons plus and minus at the same time until you hear a beep The focus values will show via On Screen Display Setup menu Access the Setup menu by pressing the round center button for 1 second See s...

Page 8: ... to USB or your microscope internal storage press the image capture button until you hear a beep Long press on the same button will save an image with graphics causing the live image to freeze for a few seconds This button also turns Auto Snapshot on off when activated via the Setup menu When taking a picture an information window will appear for a few seconds showing the file name and storage loc...

Page 9: ...he right and left arrows to choose between the different settings in the microscope menu Activate an application or submenu by pressing Enter If you have selected Exit pressing Enter will close down the menu Activate presets number keys 0 9 Using number keys 0 9 will activate Preset 1 to 10 Press number key 1 to activate Preset 1 key 2 to activate Preset 2 and so on Press number key 0 to activate ...

Page 10: ...flat surface Follow the on screen directions to find the optimal working distance The magnification settings prior to performance will be restored 3 Close up Lens Indicate which lens is mounted on your TAGARNO microscope to get the right magnification levels displayed in the On Screen Display when zooming in and out 4 Start magnification Choose the start magnification level you want your TAGARNO m...

Page 11: ...characters missing in the scanned image name 16 Image preview This feature allows users to quickly inspect and capture images of new samples When an image is captured the default behavior is to preview the image at the center of the display for 5 seconds Image preview can now be disabled which will display a more discrete text box for 3 seconds 2 GENERAL SETTINGS 1 Ruler color Set the ruler color ...

Page 12: ... Japanese Korean Polish Romanian Russian and Spanish 11 Keyboard layout Select your horizontally language by pressing buttons left or right on the XPLUS control box The available languages are listed alphabetically The microscope is by default set to GB The available languages are AF AL AT BE BR BW CA CD CZ DE DK EE ES FI FR GB HR HU IS IT LT LV ME MT NL NO PH PK PL PT RO RU SE SI SK SN TZ US VN a...

Page 13: ... top of your live image on screen For more info see manual section STANDARD APPS 4 Watermark Create an info field on captured images with an image prefix time stamp horizontal field of view microscope model plus serial number and or import and add a custom defined watermark The watermark will then appear on all captured images For more info see manual section STANDARD APPS 5 Verification lines Thi...

Page 14: ...storage does not currently have this file system use this function to format the USB storage A second pop up will ask you to confirm your selection Please notice that all files on the USB memory stick will be deleted once formatting begins Formatting time will vary 6 Ruler calibration Perform a linear calibration of the Ruler app using printable TAGARNO calibration rulers if the mounted lens is no...

Page 15: ... or cancel an ongoing focus stacking All current settings used during Focus stacking except zoom level are persisted during power down 2 RULER With Ruler you can add vertical and or horizontal rulers in a variety of colors on top of your live image Get started with the app Before using the application make sure to specify which lens is currently mounted on the microscope in the microscope camera s...

Page 16: ...tings at the same time 2 Enable or disable info field Enable or disable an info field automatically stating an image prefix default or as stated under Camera settings time stamp horizontal field of view plus microscope model and serial number 3 Enable or disable a custom watermark Choose to enable or disable the latest imported custom watermark 4 Import a custom watermark At this stage you are abl...

Page 17: ...ess of method verify that an IP address of the microscope is displayed in the microscope System information If no IP address is stated check that all cables are connected correctly or consult a network administrator Afterwards follow the description below matching your operating system to access the files NB xxxxx denotes the microscope serial number which is available on the product label and via...

Page 18: ...nk www tagarno com firmware download 2 Download the installation file s to a USB memory stick FAT32 formatted 3 If the file s is in a ZIP folder unzip the files and make sure that only the correct installation file s or previous system update files appear on the memory stick Note File names always have the following format tagarno_fhd_system_vx_xx image tagarno_fhd_system_vx_xx system tagarno_fhd_...

Page 19: ...em update STEP 5 VERIFY INSTALLATION 1 Verify the system update by checking that the Application version displayed in the Setup menu Info System information matches the version of the system update file STEP 6 ACCESS THE APPLICATION If a new application is available either through the 30 day trial license of after application installation a new menu point will appear in the Setup menu under pt 3 A...

Page 20: ...e it with a unique license key file To activate a license key on your TAGARNO microscope follow the steps below Note The license can only be paired with the microscope which has the serial number stated in your license The license can not be removed and transfered to another microscope STEP 1 DOWNLOAD LICENSE KEY FILE 1 You will receive an e mail with a unique license key file after placing an ord...

Page 21: ... Monitor Detect Yes Plug connection 2 x USB 2 0 Type A Socket USB 3 0 output Type B Socket Control box D SUB 9 Pin Female ESD Snap Socket 10mm Monitor output HDMI Standard Type A Power supply DC Jack Ethernet RJ 45 Power requirements Line voltage frequency 100 240V 10 50 60Hz Line frequency 50 60Hz AC current consumption typ 200mA 100V 90mA 240V DC current consumption typ 1 7A 12V Temperature Stor...

Page 22: ...itor arm Flexarm XPLUS FHD Control box Table mount monitor arm Cleaning kit Foot switch Wall mount monitor arm Dust cover TAGARNO Ring light White Circular tilting table Coaxial light TAGARNO Ring light IR Height Adjustment Table Glass table TAGARNO Ring light UV XY table separate FIELD OF VIEW MAXIMUM MINIMUM Lens X Direction Y Direction X Direction Y Direction 4 290 mm 11 42 163 10 mm 6 42 10 50...

Page 23: ...nVidia GeForce GT 740M with 2GB RAM Monitor resolution 1920x1080 FULL HD 1080P 25 30HZ OS Desktop Laptop Windows 7 8 or 10 with DirectX 11 Memory 4GB CPU Intel Core Dual 3 0GHz or i3 2 4GHz 4th generation named 4xxx or newer Intel Core i3 3 2GHz 4th generation named 4xxx or newer Hard Disc Space 1GB required SSD type recommended Connections USB 3 0 xHCI host controller Intel chipset recommended In...

Page 24: ... will be free from defects in material and workmanship for a period of 24 months 2 years from date of invoice from Supplier This warranty covers a The replacement of defective parts b All labour costs to exchange defective parts in product c Complete functions test of product before return to end user s site d Return transport costs of product from TAGARNO to end user s site The warranty only appl...

Page 25: ...IPTION TAGARNO A S hereby declares that the product listed above consisting of a camera unit and a 12V power supply is in compliance with the following European directives 2006 25 EU 2014 30 EU 2014 35 EU By conforming to the following harmonized standards IEC 62471 2008 EN 61326 1 2013 IEC 61010 1 2010 THE DECLARATION IS ISSUED BY MANUFACTURER TAGARNO A S TAGARNO A S Sandøvej 4 8700 Horsens Denma...

Page 26: ...ency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense INDUSTRY CANADA COMPLIANCE STATEMENT CAN ICES 3 A NMB 3 A This Class A digital appar...

Reviews: