background image

TAB 

e.

module L5.1

 

Li-ion Energy Storage System

OPERATION MANUAL

Summary of Contents for e.module L5.1

Page 1: ...TAB e module L5 1 Li ion Energy Storage System OPERATION MANUAL...

Page 2: ......

Page 3: ...ng of lithium batteries guide 13 4 1 Schematic diagram of solution 13 4 2 Danger label 13 4 3 Tools 14 4 4 Safety Gear 14 5 Installation and operation 15 5 1 Package items 15 5 2 Installation location...

Page 4: ...nual introduces L5 1 e module from TAB Please read this manual before using and follow the instruction carefully during the installation process Any confusion please contact TAB for advice and clarifi...

Page 5: ...not place near open flame Do not place at the children and pet touchable area Warning electric shock Warning Fire Do not place near flammable material Read the product and operation manual before oper...

Page 6: ...hing abnormal 9 Do not use cleaning solvents to clean battery 10 Do not expose battery to flammable or harsh chemicals or vapors 11 Do not paint any part of battery include any internal or external co...

Page 7: ...afety standards 3 Introduction L5 1 lithium iron phosphate battery is the new energy storage product developed and pro duced under TAB s quality requirements it can be used to support reliable high po...

Page 8: ...p to 6 months without charging it on shelf no memory effect excellent performance of shallow charge and discharge 12 Small size and light weight standard of 19 inch embedded designed module is 13 comf...

Page 9: ...85 CAN Configuration max in 1 battery group 32pcs Working Temperature 0 C 55 C Charge 20 C 55 C Discharge Shelf Temperature 20 C 35 C Short current duration time 2000A 1ms Cooling type Natural IP rati...

Page 10: ...the battery has alarm lighting to show the battery is under pro tection Warning In case of a warning ALM LED starts blinking yellow Alarm In case of an alarm ALM LED starts blinking red The module di...

Page 11: ...ed DI1 Pin6 Not defined DI2 Pin7 Low SOC Signal Reay switches on when SOC drops below 15 Relay 1 COM Pin8 Relay 1 NO Pin9 Relay 1 NC Pin10 Charge Enabled Relay switches on when charging is enabled Rel...

Page 12: ...ables uses self locked connectors must keep pressing this Lock Button while pulling out the power plug LED Status Indicators Condition RUN ALR 1 2 3 4 5 Power off Power on Show Power on Animation Idle...

Page 13: ...el Discharge Under Voltage Charge Discharge Current Limit Charge Discharge Over Current Capacity Retention Calculate High Low Temperature cell BMS Administrator Monitor Short Circuit Operation Record...

Page 14: ...ols to prevent accidental electric shock or short circuits If insulated tools are not available cover the entire exposed metal surfaces of the available tools except their tips with electrical tape 4...

Page 15: ...al cable kits NOTE Power and communication cables connect to inverter belongs to an External Cable Kit NOT include in battery carton box They are in another extra small cable box If there is anything...

Page 16: ...ant level 6 There is minimal dust and dirt in the area 7 The distance from heat source is more than 2 meters 8 The distance from air outlet of inverter is more than 0 5 meters 9 The installation areas...

Page 17: ...Upside down Sidelong Sidelong Recommended Note A Caution Do not stack modules together directly B Caution Make sure there is holder for more than 50kg weight at bot tom of each module Installed only...

Page 18: ...l directly touch between the mo dule s surface and rack s surface If using painted rack the corresponding place shall remove the painting 2 install a grounding cable to the grounding point of the modu...

Page 19: ...ystem and inverter 1 The rated voltage shall 60V DC Do NOT use AC breaker 2 The rated current shall match with system design shall consider the maximum DC current on inverter side the number of power...

Page 20: ...by one from the Master battery Note 1 After the battery module powered on the soft start function takes 3sec to active After soft starts battery ready to output high power 2 During capacity expansion...

Page 21: ...flashing a Capacity too low or module over discharged solution use a charge or inverter to provide 48 53 5V voltage If battery can start then keep charge the module and use monitor tools to check the...

Page 22: ...erature Above 60 C or under 10 C the battery could not work Solution to move battery to the normal operating temperature range between 0 C and 50 C c Current If current exceeds 100A battery protection...

Page 23: ...er the charge voltage shall be 58 4Vdc Check the communica tion between battery system and inverter whether established or not Check the ADD switch on battery module whether is set correctly or not Un...

Page 24: ...n Induce vomiting and seek medical attention 2 Fire If detect the battery cell is catching fire firstly cut off the external power source Then use vast of water for suppression After fire suppressed s...

Page 25: ...s for this charge maintenance make sure the SOC is charged to higher than 90 2 Every year after installation The connection of power connector grounding point power cable and screw are suggested to be...

Page 26: ...TAB d d Polena 6 2392 Mezica Slovenia Tel 386 2 87 02 300 Web www tab si E mail info tab si TAB_V1_01_2023 P U R E E N E R G Y M A X I M U M P O W E R...

Reviews: