background image

Handheld Slit Lamp Microscope

SK

Operation

Instruction

Manual

Handheld slit lamp

LS-1

Summary of Contents for LA-1B

Page 1: ...Handheld Slit Lamp Microscope SK Operation Instruction Manual Handheld slit lamp LS 1 ...

Page 2: ...Installation 6 3 3Debugging 7 3 4 Installation Instruction of the Battery 9 3 5 The charging indicator 11 4 Usage and requirements 12 4 1 Requirements 12 4 2Usage 12 5 Maintenance and preventive inspection 13 5 1Maintenance 13 5 2Preserve 13 5 3preventive inspection 13 6 Transportation and storage 14 7 Graphic symbol interpretation 15 7 1 Graphic symbol interpretation on instrument 15 7 2 Graphic ...

Page 3: ...on as well as the datum of the instruments carefully before using it Please check following before your using 1 Please check the instrument accessories are consistent with the packing list or not 2 Please read accompanying files carefully and keep properly The pictures in instructions only for reference purpose if you have any questions please feel free to contact with your local agents Hotline 86...

Page 4: ...rightness not lower than 50 000lux work life can be 50 000 hours 2 Sharp images you can get Frequently used slit width design meet regular clinical needs 3 Telescopic forehead rest easier to observe and adjust diopter 4 Magnification transfer with lever Coordinated pupil distance adjustment with good hand feeling 5 Small and lightweight 6 Different filters Heat absorption red free cobalt blue 7 Fu...

Page 5: ...ructure diagram 1 Eyepiece 2 Diopter adjustment Adjust the diopter to get the clear image 3 Adjust the pupil distance 4 Objective magnification changer 10 16 For LS 1B only 5 Brightness adjusting knob From left to right the brightness brighten up 6 Handle 7 Charging power supply socket ...

Page 6: ...usting knob 14 Filters adjusting knob 15 Slit angle adjusting track 1 4 Models difference Model Hardware structures magnification Visual field diameter LS 1A Optical body movement mechanism illumination system hand held handle power supply 10X 10X 11 mm 16X 7 mm LS 1B optical body movement mechanism illumination system hand held handle power supply 10X 16X 1 5 Product label ...

Page 7: ...tion 8D 8D Resolution of visual center 16X NA 0 0448 10X NA 0 0402 Nominal diameter of visual field 10X 11mm 10X 11mm 16X 7mm Illumin ation Slit width 0 15mm 0 5mm 0 8mm 1 6mm ф12mm 1X1mm square Slit length 12mm Slit angle Horizontal 60 Filters Neutral density Red free Cobalt blue Inbuilt IR UV cut filter Lighting bulb High brightness white LED brightness 50000Lux Power supply LED work voltage DC7...

Page 8: ...list figure 1 16X objective for LS 1B only 1 Portable slit lamp 2 Chargeable power adapter 3 Power line 4 Forehead rest bracket support patient forehead and fixed the position between slit lamp and patient to avoid shaking 3 2 Installation 3 2 1Install the chargeable power adapter Take out the chargeable power adapter and connecting with power line and the portable slit lamp figure 2 ...

Page 9: ... 2 2 Forehead rest bracket Take out the forehead rest bracket align the mounting hole on the optical body and tighten the fixed screw figure 3 Figure 3 3 3 Debugging 3 3 1 Adjust the pupil distance and diopter ring Adjusting the eyepiece diopter ring according to operator s diopter for example emmetropia adjust to 0 degree as figure 4 show and adjust the pupil distance well ...

Page 10: ...itch adjust the brightness knob to largest figure 6 the light will project from optical body adjust the focus distance to put the spot in the central of focal plane brightness uniformity and boundaries clear Figure 6 3 3 4 After debug finished installing the forehead rest bracket and start to use Installation method please refer to 4 2 3 Adjust PD Adjust diopter Aperture and slit width adjusting k...

Page 11: ... Medical Instrument Co Ltd 9 3 4 Installation Instruction of the Battery 1 Put the handle slit lamp flat on a table Fig 1 and prepare a phillips screwdriver 2 Remove the screw in picture 2 Fig 2 then take the lid off Fig 3 ...

Page 12: ... battery and plug into the power outlet on the equipment with force after aiming the plug at the outlet and be careful the direction of the plug Fig 4 5 6 4 Put the power lines and battery into the slit lamp and insert the lid back do not get the lid stuck Fig 7 8 ...

Page 13: ...ical Instrument Co Ltd 11 5 Close the lid and reinstall the set screw Fig 9 10 3 5 The charging indicator When the slit lamp is charging the indicator lamp on AC adapter is red once it finished indicator lamp will become green ...

Page 14: ...2 Usage 1 Rotating the slit width adjusting knob and filter adjusting knob to right place and rotate the illumination arm to right place also can adjust it when checking 2 Put forehead rest bracket against the patient forehead slightly turn on the power supply and adjust the brightness then the light will project to patient eye figure 8 3 observing from eyepiece and press the slit lamp slightly ga...

Page 15: ...ng period of time please put the portable slit lamp back to package and store in ventilated dry place 3 When long time in no use please charge it every half month to prolong the battery service time 5 3 Preventive inspection 1 Check if there are foreign body on the surface of portable slit lamp if has please clean it with alcohol swab 2 Check if the illumination system can move smoothly if not ple...

Page 16: ...free from exposure to the sun and rain The well packaged portable slit lamp should be stored in dry well ventilated no corrosive gas indoor where environment temperature at 5 55 relative humidity lower than 80 and the atmosphere pressure between 500 hPa 1060 hPa If the installed instrument need long distance transport it should put back to original package and then transport it ...

Page 17: ...plication part Caution Consult accompanying documents Direct current Fuse protector Brightness adjusting Change magnification Size of light spot Filter Manufacturer Date of Manufacture Recyclable 7 2 Graphic symbol on outer package interpretation Protect against moisture Stacking limit to 10 Upward Fragile O 1 6 0 8 0 5 0 15 O B F N D R F ...

Page 18: ...the slit width adjust to largest Check whether the filter is on right position Check the chargeable battery Unsharp images Adjust the diopter ring to compensate the diopter Enhanced brightness Clean the lens surface with alcohol wipes If you meet any other problem or cannot debug according to above table please contact with your local authorized distributor or to SK MED ...

Page 19: ...tor or contact Sunkingdom directly 7 Electromagnetic compatibility please do not put it with other high power machine keep at least 1 meter away from other electromagnetic equipment mobile phone heart pacemaker 8 Environmental protection clause It will pollute the environment if you discard the equipment and the accessories which is breakdown recall or disposal according to the local laws and regu...

Page 20: ...ent or we will not take the consequences 19 Do not touch the surface of lens with hand or hard objects 20 Cautionary Statement Caution The light emitted from this instrument is potentially hazardous The longer the duration of exposure the greater the risk of ocular damage Exposure to light from this instrument when operated at maximum intensity will exceed the safety guideline after 170 seconds ...

Page 21: ...ut the permission of Sunkingdom Damaged caused by accidents or irresistible natural factors All parts only can be provided by Sunkingdom the components and parts can t use in the instruments without the permission of Sunkingdom Please forgive us for not informing you if the design or the assigned type changes Name ChongQing SunKingdom Medical Instrument Co Ltd ADD 35 2 YingTian GuangDian GongGu Ca...

Reviews: