background image

Striem

3100 Brinkerhoff

Kansas City, KS 66115

Tel: 913-222-1500

Fax: 913-291-0457

www.

striemco.com

Made in the U.S.A

SI-UPC-1016

Liquid capacity: 250 gallons

Optional basket capacity: 7 gallons

Sheet Descriptions

   

Sheet #1 - Series overview and Warranty information

Sheet #2 - General installation guidelines and Operation/Maintenance guidelines

Sheet #3 - Below Grade installation guidelines

Sheet #4 - TeleGlide Riser installation guidelines 

STRIEM SAND INTERCEPTOR

(SI-UPC-1016)

Leak/Seal Testing

   

DO NOT AIR TEST UNIT OR TELEGLIDE RISER SYSTEM!  Doing so may result in property damage, personal injury or death.  

Base Unit:

  To perform a leak/seal test on the base unit, cap/plug all plumbing connections, remove the cover, and fill the unit with water just above the

highest connection. Inspect unit and connections for leaks. Check water level at specific time intervals per local code.  

TeleGlide Riser System:

  If required by local code, the riser system may be leak/seal tested similar to the base unit. 

CAUTION:

 the riser(s) must be supported

before filling with water to keep from tipping over. Once riser system is in place and properly supported, cap/plug all plumbing connections on the main unit,

remove the cover from the top of the riser assembly and fill the unit and riser system with water to finished grade level. Carefully, as the riser(s) will be very

heavy from the weight of the water, inspect all gasket(s) and clamps (if applicable) for any leaks. Check water level at specific time intervals per local code.

Lifetime Warranty

Effective March  2, 2015 Striem represents and warrants that HDPE products will be free from any and all defects in material and workmanship, including 

corrosion, during the lifetime of the plumbing system in which the Products were originally installed and will, at its option, agree to repair, replace, or supply

credit to the original purchaser.
This warranty does not cover damage caused by the products’ normal usage, or wear and tear, nor does it cover damage from naturally occurring

phenomenon, including, but not limited to UV, freeze-related damage, or natural disasters. This warranty does not cover the purchaser’s cost of routine

maintenance including replacement of parts required in routine maintenance.
This warranty does not cover fabricated steel products, or any monitoring equipment. This warranty shall be effective if, and only if, the products:

* Were installed in accordance with Striem’s notes, specifications and instructions, for installation, operation, and maintenance;

* Were installed in conformance with all applicable building and plumbing codes, and passed all applicable testing methods immediately following installation;

* Have not been subjected to misuse or abuse, whether negligent or intentional;

* Were never modified, repaired, or altered by any individual(s) not authorized by Striem.
This warranty is the purchaser’s sole and exclusive remedy, and acceptance of this exclusive remedy is a condition of the contract for thepurchase of these

products. In no event shall Striem be liable for any incidental, special, consequential or punitive damages, or for any costs, attorney fees, expenses, losses or

delays claimed to be as a consequence of any damage to, failure of, or defect in any products including, but not limited to, any claims for loss of profits,

transportation, removal and installation charges. This warranty is exclusive and in lieu of all other warranties or conditions, written or oral, expressed or implied.

SAND INTERCEPTOR INSTALLATION, 

OPERATION AND MAINTENANCE GUIDE

ECO:

02/18/19

MJ

REV:

DATE:

DWG BY:

DESCRIPTION:  

PROPRIETARY AND CONFIDENTIAL

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF 

STRIEM, LLC. 

ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF 

STRIEM, LLC. 

IS 

PROHIBITED.

NOTES:

Striem Sand Intercepyot tanks are not to be installed in any other manner except as shown.  Consult local 

codes for separate trapping requirements, cleanout locations and additional installation instructions.