Buzzer Unit BU01 Installation Guide

Check the supplied accessories

Check the following table to see which parts are needed for each model, then follow the procedures to install the buzzer.
The following lists all included parts except for this manual. If parts are missing or damaged, please contact the retailer.

Note: To ensure safety, be sure to turn OFF the power and disconnect the printer power plug from the electric outlet before beginning installation.

l

 

For mC-Print3

1.

 

Remove the ground fitting by sliding it in the direction of the arrow.

2.

 

Pull the 4 hooks on the lower case outwards, and remove the upper case. Remove the 2 screws, and remove the buzzer from the lower case.

 

  

 

 

 

 

 

 

 

 

 

 

 

 

[See Fig. 1]

3.

 

Insert your fingernails into the slits on the left and right of the rear cover, and unhook the cover one side at a time. [See Fig. 2]

4.

 

Install the buzzer, and secure it using the 2 included M2.6 screws. [See Fig. 3]

 

Connect the connector of the buzzer cable to the external device port on the printer to complete the installation. [See Fig. 4]

5.

 

Insert hooks A into the slits of the printer, and push until left and right hooks B click into place. [See Fig. 5]

Installing the buzzer on the printer

l

 

For SP700

1.

 

Install the buzzer on the bottom surface of the printer, and secure it using the 2 included 
M3 screws.

2.

 

Connect the connector of the buzzer cable to the external device driver port on the printer 
to complete the installation.

l

 

For TSP100/Ⅱ/Ⅲ/650Ⅱ series

1.

 

Remove the ground fitting by sliding it in the direction of the arrow.

2.

 

Pull the 4 hooks on the lower case outwards, and remove the upper case. Remove the 2 screws, and remove the buzzer from the lower case.

 

  

 

 

 

 

 

 

 

 

 

 

 

 

[See Fig. 1]

3.

 

Install the buzzer onto the bracket, and secure the buzzer using the 2 included M2.6 screws. [See Fig. 2]

4.

 

Stow the buzzer cable between the buzzer and the side of the bracket. [See Fig. 3]

5.

 

Insert the hook of the bracket into the printer, and secure the bracket using one of the included M3 screws. Connect the connector of the buzzer 
cable to the external device port on the back of the printer to complete the installation. [See Fig. 4]

l

 

For TSP700II

1.

 

Remove the ground fitting by sliding it in the direction of the arrow.

2.

 

Pull the 4 hooks on the lower case outwards, and remove the upper case. Remove the 2 screws, and remove the buzzer from the lower case.

 

  

 

 

 

 

 

 

 

 

 

 

 

 

[See Fig. 1]

3.

 

Install the buzzer onto the cable cover, and secure the buzzer using the screws removed in step 2. [See Fig. 2]

4.

 

Connect the connector of the buzzer cable to the external device port on the back of the printer. [See Fig. 3]

5.

 

Install the cable cover onto the printer. [See Fig. 4]

6.

 

Affix the blind plate to the cable cover to complete the installation. [See Fig. 5]

Copyright © 2007-2018 Star Micronics Co., Ltd.  80871952

Supplied accessories

Bracket

Buzzer

M2.6 screws x 2

M3 screws x 2

Blind plate

Ferrite core

mC-Print3 Series

Not Used

Used

Used

Not Used

Not Used

Not Used

SP700 Series

Not Used

Used

Not Used

Used

Not Used

Not Used

TSP100/Ⅱ/Ⅲ Series

Used

Used

Used

Only 1 required

Not Used

Not used except for TSP100GT

Used with TSP100GT only

TSP650Ⅱ Series

Used

Used

Used

Only 1 required

Not Used

Not Used

TSP700Ⅱ Series

Not Used

Used

Not Used

Not Used

Used

Not Used

A

A

B

B

Wiring the

Cables

TSP100 Series

10mm

TSP100GT only

TSP650 Series

These screws 

are not used.

Upper case

Lower case

Ground fitting

M2.6 screws

Used when installing 

the cable cover

[Fig. 1]

[Fig. 2]

[Fig. 3]

[Fig. 4]

[Fig. 1]

[Fig. 2]

[Fig. 3]

[Fig. 4]

[Fig. 1]

[Fig. 2]

[Fig. 3]

[Fig. 4]

[Fig. 5]

M3 screws

M3 screw

Bracket

Cable cover

Blind plate

[Fig. 5]

Rear cover

(Rear surface of the printer)

Ground fitting

Ground fitting

These screws 

are not used.

Upper case

Lower case

Upper case

Lower case

Summary of Contents for BU01

Page 1: ...using the 2 included M2 6 screws See Fig 2 4 Stow the buzzer cable between the buzzer and the side of the bracket See Fig 3 5 Insert the hook of the bracket into the printer and secure the bracket using one of the included M3 screws Connect the connector of the buzzer cable to the external device port on the back of the printer to complete the installation See Fig 4 l For TSP700II 1 Remove the gro...

Page 2: ...ネジ 2 本で固定します 図2参照 4 ブザーケーブルをブラケット内に収納します 図3参照 5 プリンターにブラケットのツメを引っかけて取り付け 同梱部品の M3 ネジ 1 本で固定します ブザーケーブルのコネクターをプリンター背 面の外部機器用コネクターに接続し 完了です 図4参照 TSP100GTをお使いのときは フェライトコアを取り付けてください TSP700Ⅱの場合 1 アース金具をスライドして取り外します 2 下ケースにある4ヶ所のツメを外側へ広げ上ケースを取り外します 2 本のネジを外し 下ケースからブザーを取り外します 図1参照 3 ブザーをケーブルカバーに取り付け 手順 2 で取り外したネジ2本で固定します 図2参照 4 ブザーケーブルのコネクターをプリンター背面の外部機器用コネクターに接続します 図3参照 5 ケーブルカバーをプリンターに取り付けます 図4参照 6 ブライ...