i4 Operating Instructions

DC Power Port

36.50

 89.00

 173.00

iButton Reader 

Connector

Status Indicating LED’s

Device/Recoiler In

Smaller on the outside, 

much bigger on the inside

Summary of Contents for i4

Page 1: ...i4 Operating Instructions DC Power Port 36 50 89 00 173 00 iButton Reader Connector Status Indicating LED s Device Recoiler In Smaller on the outside much bigger on the inside ...

Page 2: ...n Reader operation Understanding the beeping sequence when using a single iButton Reader Multiple independent iButton Reader operation Understanding the beeping sequence when using multiple independent iButton Readers Adding and removing black iButton Keys user Disable battery back up Reset the i4 and add red iButton Keys master ...

Page 3: ...10 battery to begin with Local or global alarm operation As default the i4 is supplied with one iButton Reader that is used to operate the alarm The i4 offers independent alarm management meaning four seperate iButton Readers can be used Battery backup Battery backup ensures that each product remains electronically secured if local power fails Battery back up lasts up to 48 hours Alarm sounder Fit...

Page 4: ... master Slide Detection Sensor referred to throughout as Sensor Connection socket for Recoiler Alarm status LED Tamper switch Locking plate ensures solid connection between Recoiler and Sensor iButton Reader Page 4 iButton Keys and Reader Slide Detection Sensor Sensor ...

Page 5: ...er referred to throughout as Recoiler Status Indicators blue LED iButton Reader connector Device Recoiler port Power in HS Sensor connector Inserts directly into the Sensor RJ12 plug connects into one of the i4 device Recoiler ports ...

Page 6: ...73mm Depth 89mm Height 36 5mm Operation 1 Single iButton Reader can be used for all ports 2 Dedicated iButton Reader per port device each connected product is managed independently Retrofit Compatible with existing Recoilers and MultiSensors i4 specification Indicating LED s Indicating LED s will switch off if the i4 alarm is set and no problems are present Blue flashing LED if a problem arises an...

Page 7: ...uch the black iButton Key to the iButton Reader to set the alarm To add or remove Recoilers Sensors to ports In order to add or remove a Recoiler and or Sensor please disarm the i4 by placing the black iButton Key onto the iButton Reader once Add or remove the Recoiler Sensor each Recoiler must have a Sensor and a product handset fitted in order to depress the tamper switch found on the Sensor and...

Page 8: ...still armed Connect PSU Intermittent beep and iButton Reader is intermittently flashing red The i4 battery backup has activated alarm is still armed Connect PSU Intermittent 5 beeps Unit beeps once per second no light on iButton Reader No iButton programmed Refer to Programming Guide iButton Reader flashing orange A Recoiler is fitted without a Sensor attached Check connection Is the iButton Reade...

Page 9: ...ensor detected Recoiler Sensor detected and secured Recoiler Sensor detected not secured or fault Auto Reset If a sounding alarm has been silenced the i4 will auto reset once the product has been re secured If the i4 has been disarmed or if user intervention is required then it will be neccessary to touch the black iButton Key to the iButton Reader to set the alarm To add Recoilers and Sensors to ...

Page 10: ...hat port but is not securing a product Understanding the beeping sequence when using multiple independent iButton Readers i4 making a sound other than alarm Beep every 2 seconds green iButton Reader Continuous beeping no light on iButton Reader No iButton Readers are connected The i4 is disarmed Intermittent double beep and iButton Readers intermittently flashing red twice The i4 battery backup ha...

Page 11: ...ittently to signal an iButton can be added 3 Touch the red iButton Key onto any iButton Reader a second time 4 The unit will start to beep twice intermittently to signal that black iButton Keys can be added or removed 5 If this state was enterred by accident touch the red iButton onto the iButton Reader a third time to exit back to the state the alarm was in before programming mode was enterred wi...

Page 12: ...1 If using a single iButton Reader to manage the i4 alarm please disarm the alarm by pressing the black iButton Key onto the iButton Reader If using multiple iButton Readers please press the black iButton Key onto each iButton Reader to disable each of them 2 Remove all Recoilers from the alarm unit The alarm will start to signal that there is an issue with Recoilers 3 Remove all iButton Readers A...

Page 13: ...red iButton Key onto the iButton Reader and the alarm will double beep 4 This indicates the red iButton Key has now been added Up to 5 red iButton Keys can be added to one i4 5 If the alarm makes a long buzz then the red iButton Key is already programmed or there has been a problem reading the red iButton Key 6 Unplug the power to the i4 to exit the iButton Programming Mode 7 Reconnect the power c...

Page 14: ...ales stacey europe co uk Outside of the UK Please contact your supplier Address Stacey Europe Ltd Lancaster Fields Crewe Gates Ind Est Crewe Cheshire CW1 6FF United Kingdom Web www stacey europe com Email sales stacey europe com ...

Reviews: