background image

Herpstat 

EZ Series

  

User’s Manual 

 

 

 

 
 
 

 
 

 
 

www.spyderrobotics.com

 

Thank you for choosing the Herpstat digital proportional thermostat.  This product 

offers the following features: 

 

 

Proportional heating constantly monitors and adjusts amount of heat necessary to maintain a target 

temperature (usable range from 70˚F to 110˚F).   
 

 

Dimming and Pulse heating modes. 
 

 

Basking Assist control built in to work with basking lights. 
 

 

Glowing LED snake eyes indicate measured temperature and heat status. 
 

 

Soft startup slowly applies power during initial warm-ups. 

 

 

Auto Power Matching constantly adjusts the power output curve to match the enclosures efficiency. 

 

 

Precision temperature sensors with an internal resolution of .1125 ˚F and are accurate to ± .9 ˚F 

 

 

Removable sensors allow for easy replacement if necessary. 

 

 

User replaceable fuse. 

 

 

Audible alarm system. 
 

 

30 minute low temperature alarm. 

 

 

Over temperature alarm. 

 

 

Internal error detection shuts off heat if sensor fails or is disconnected. 

 

 

400 total watt output for the Herpstat EZ1  
 

 

600 total watt output for the Herpstat EZ2  
 

 

1 year limited warranty. 

 

 
 

 
 

About this User's Manual 

 

This manual covers both the Herpstat EZ1 and Herpstat EZ2 products.  The Herpstat EZ2 adds a second output 
and probe with its own independent setting knob.   

 

 
 
Hardware Installation 

 

WARNING – FIRE OR ELECTRICAL SHOCK MAY RESULT FROM MISUSE.  FOR INDOOR USE ONLY!  

 

Herpstat 1:  Do not exceed 400 watts. 
Herpstat 2:  Do not exceed 300 watts on either output. 

 

1.

 

Each AC receptacle on the Herpstat has a corresponding probe jack on the side of the unit.  On the 
Herpstat EZ2 the probe jack on the top is used with the left dial and outlet.  The lower probe jack 
belongs to the dial and outlet on the right side of the unit. On the Herpstat EZ2 its very important to 
keep the probe and outlets matched or else an overheat condition can occur. 

  

2.

 

Attach the Herpstat electrical cable to the bottom of the unit and to a standard wall outlet.   

 

3.

 

Attach the heating device to the AC outlet receptacles on the Herpstat.  These devices may include 

heat tape, heat coils, basking lights, ceramic heat emitters, heat mats or other resistive load heating 
devices. Not recommended for use with rock heating devices or other devices that come in direct 
contact with the animal. Do not connect oil-filled heaters or other space heaters.   
 

 

 
Installation Tips: 
 
We do not recommend using aluminum tape to secure the probes.

  This can cause false readings and 

poor regulation.   
 
Route the probe wires so that they are not in direct contact with the 120vac cables going to the heating devices.  
Preferably leave at least a few inches between the probe wires and the AC lines to avoid cross talk/electrical 

interference issues. 
 
Mount the device in a dry indoor location away from additional heat and humidity sources.  During operation it is 
normal for the Herpstat's enclosure to be warm to the touch.  

 
Electrical surges can damage a thermostat.  Use a good quality surge suppressor connected between the wall 
and Herpstat. 
  

 
 
Setup Procedure 

 

Install the probe where you want to measure / regulate temperature.  Recommendations on probe placement 
can be found on our website here:  
 

 

http://www.spyderrobotics.com/probe

 

 
Adjust the knob to your desired temperature.  The indicated temperatures on the thermostat are an 

approximate setting in Fahrenheit.  Use a separate thermometer in the enclosure and adjust the knob 
accordingly to reach your desired temperature. When the knob is adjusted a short double beep will sound and 
the LED will flash green indicating that it is recognizing a new temperature.  Once it recognizes the dial has 
stopped moving a three beep indicator will sound and the LED will flash green acknowledging the change. 

 

NOTE:  Any time a knob is adjusted the thermostat will wipe its previously learned power curves and 
go through the process of relearning exactly how much power the enclosure needs to maintain the 
new temperature.  Give the unit time to adjust before determining if further changes are needed.   

 

 

Checking Device Firmware: 

 

When unit is first plugged in the LED’s will blink the firmware version.  The number of red blinks on the left eye 
is the whole number and the number of green blinks on the right eye will indicate the tenth of the revision.  
Then an audible beep will sound indicating the unit is starting normal operation. 

 
 

Reviews: