background image

BP-12A

12-Volt, DC Rechargeable Battery Pack

INTRODUCTION
The BP-12A battery pack is specially designed for use with
Spectroline® 12-volt, "instant-on" inspection lamps.
The BP-12A battery pack includes a 12VDC, 7.2-amp hour
rechargeable battery and a fused receptacle packed in a
nylon carrying case with an adjustable web shoulder strap.
The 12-volt plug receptacle is used for recharging and 
connecting to the lamp using its 12-volt plug. A 120VAC,
12VDC-1000mA  battery charger (RB-12S) is included.
NOTE: The BP-12A/F battery pack includes a 230VAC,
12VDC-1000mA charger (RB-12S/F). The BP-12A/J 
battery pack includes a 100VAC, 12VDC-1000mA charger 
(RB-12S/J).

USING THE BP-12A BATTERY PACK
The BP-12A must be fully charged before using.
•  
Check that the voltage characteristics of the battery 

charger match the voltage of the AC outlet.

•  Connect the 12-volt plug to the fused battery receptacle.
•  Plug the battery charger supplied into a properly regulated

AC outlet.

•  NOTE: The charger requires approximately 12 hours to

charge fully, depending on the discharge level of the 
battery. The red LED indicates the charger is being
charged, while the green LED indicates it is ready for use.
The charger will not overcharge. For maximum battery life,
recharge the battery within 24 hours after each use and
before a voltmeter registers as low as 10 volts.

•  After the battery is charged, first unplug the charger from

the outlet, then unplug it from the fused receptacle.

USING THE BP-12A BATTERY PACK WITH THE LAMP
1. Plug the 12-volt plug adapter of the lamp into the fused

battery receptacle.

2. Turn on the lamp.
3. Before storing, cleaning or servicing, disconnect the 

lamp from the battery pack and allow it to cool. Refer to
the operating instructions packed with the lamp for full
information.

TROUBLESHOOTING THE BP-12A BATTERY PACK
If the bulb does not light, it indicates low voltage from
the power source, a faulty connection, a faulty battery 
or the need for bulb replacement. Refer to the operating
instructions packed with the lamp for full information.

1.Check that the lamp plug is firmly seated in the battery

receptacle.
Disconnect the lamp before doing the following 
troubleshooting!

2.Use a voltmeter to check the battery terminals. Recharge

the battery if necessary. For maximum battery life,
recharge the battery before it registers as low as 10 volts.

3.If the battery does not recharge, disconnect it from the

charger. Use a voltmeter to check for proper DC voltage
at the charger output. If the voltmeter registers 13.2 volts
or above, the charger is working properly and the battery
should be replaced.

4.Use a voltmeter to check for DC voltage output at the 12V

plug receptacle. If the battery is fully charged and the 
voltage still registers zero, replace the fuse. Simply pull it
out and insert a new one. Use a Buss ATC fuse or a
Littelfuse ATO 257-series fuse of the same amperage 
supplied with the BP-12A. Either fuse is available at your
local auto parts store.

If the problem persists, contact your Spectroline 
distributor or the Customer Service Department of
Spectronics Corporation.

WARRANTY
The warranty policy for the BP-12A battery pack is provided
on the Certificate of Limited Warranty enclosed separately
with each unit.
NOTE: For assistance of any kind, contact the Customer
Service Department at Spectronics Corporation. In the U.S.
and Canada, call toll-free 1-800-274-8888. Outside the U.S.
call 516-333-4840. Give full details of the difficulty and
include the model and serial numbers of the unit and the
date of purchase. If return of the unit to the factory is
deemed necessary, shipping instructions will be provided.
If an estimate of charges for nonwarranty work or other
service work is required, a quote will be furnished upon
evaluation of the unit. Out-of-warranty service work will not
be performed without customer approval.

BP-12A

12 Volts, bloc de batteries rechargeables

INTRODUCTION
Le bloc de batteries BP-12A a été spécialement conçu pour
être utilisé avec les lampes d'inspection « instantanée »
Spectroline® 12 volts.
Le bloc de batteries BP-12A comprend une batterie
rechargeable 12 V CC, 7.2 A/h et une prise munie de
fusibles intégrée à un boîtier de transport en nylon avec 

English

IMPORTANT

Please read all operating instructions before 

using the BP-12A 12-volt, rechargeable battery
pack.

WARNING

Use only the charger supplied to recharge the 
battery. Other chargers may harm the battery and
will void the battery’s warranty. Recharge in a well-
ventilated, dry area. Do not expose the battery 
to high temperatures. The maximum allowable 
temperature should be below 140°F (60°C).

®

®

French

IMPORTANT

Les instructions de fonctionnement doivent 

être lues avant d'utiliser le bloc de batteries 
rechargeables BP-12A, 12 volts.

Summary of Contents for BP-12A

Page 1: ...battery life recharge the battery before it registers as low as 10 volts 3 If the battery does not recharge disconnect it from the charger Use a voltmeter to check for proper DC voltage at the charger output If the voltmeter registers 13 2 volts or above the charger is working properly and the battery should be replaced 4 Use a voltmeter to check for DC voltage output at the 12V plug receptacle If...

Page 2: ...atterie la recharger avant qu elle n indique une tension de 10 volts 3 Si la batterie ne recharge pas la déconnecter du chargeur Utiliser un voltmètre pour vérifier la tension continue à la sortie du chargeur Si le voltmètre indique 13 2 volts ou au dessus le chargeur fonctionne correctement et la batterie doit être remplacée 4 Utiliser un voltmètre pour vérifier la tension continue sur la prise 1...

Page 3: ...ación máxima de la batería recárguela antes de que registre un voltaje de 10 voltios o menos 3 Si la batería no recarga desconéctela del cargador Use un voltímetro para determinar que la salida del cargador tiene el voltaje de CD apropiado Si el voltímetro registra más de 13 2 voltios el cargador está trabajando apropiadamente y la batería debe reemplazarse 4 Use un voltímetro para verificar el vo...

Page 4: ...m eine maximale Lebensdauer der Batterie zu gewährleisten sollten Sie die Batterie aufladen bevor nur noch 10 Volt registriert werden 3 Wenn sich die Batterie nicht auflädt trennen Sie sie vom Ladegerät Prüfen Sie mit einem Spannungsmesser ob die Gleichstromspannung am Ladegerätausgang richtig ist Wenn der Spannungsmesser 13 2 Volt oder mehr registriert funktioniert das Ladegerät richtig und die B...

Reviews: