background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Part Number:   

02005001A

 

Revision:  

 

0

 

Language:  

 

UK

 

English

 

 

SERVOPRO PureGas 

OPERATOR MANUAL 

 

OPERATOR MANUAL 

Summary of Contents for Servomex Servopro PureGas

Page 1: ...Part Number 02005001A Revision 0 Language UK English SERVOPRO PureGas OPERATOR MANUAL OPERATOR MANUAL ...

Page 2: ...This page is intentionally blank ...

Page 3: ...all and Fixing Dimensions Standard 10 11 4 1 2 Figure 2 Overall and Fixing Dimensions VCR 11 4 2 Mechanical Installation and purging 12 5 Operation 13 5 1 Activating 13 5 2 Electrical Safety 13 6 Disconnecting the Purifier 14 7 Service 15 7 1 Cleaning the Purifier 15 8 STORAGE AND DISPOSAL 16 8 1 Storage 16 8 2 Disposal 16 9 APPENDIX 17 9 1 APPENDIX A1 MATERIALS IN CONTACT WITH SAMPLE GAS 17 9 2 A...

Page 4: ... made to install operate or maintain the purifier Important safety information is highlighted in this manual as WARNINGs and CAUTIONs which are used as follows This manual also incorporates Be Aware of information which is used as follows This highlights information which is useful to be aware of for example specific operating conditions 1 3 Warning Symbols The identification label on the front of...

Page 5: ...could cause a fire or permanent damage to the purifier voiding the factory warranty WARNING Improper installation operation or service of the purifier can cause fire and electrocution WARNING If a fire occurs inside the purifier extinguish the fire with sand or an extinguisher intended for class d metal fires only Do not attempt to extinguish a purifier fire with any other materials WARNING The pu...

Page 6: ...ty B50 200 Bar cylinders of typical 5 nines quality 99 999 carrier gas or one hundered and twenty cylinders of typical 6 nines quality 1 7 Construction The purifier comprises of an aluminium enclosure which has ventilation holes at the top and bottom There is a mounting bracket at the rear of the purifier Anodized enclosure maintains a 45º C surface temperature Ceramic fibre insulation with encaps...

Page 7: ...nstream of Getter vessels 304L SST all welded construction 2 2 Environmental Limits 2 3 Electrical Data Installed Power Customer to specify voltage at time of order 120 VAC 1 Phase 50 60 Hz 220 VAC 1 Phase 50 60 Hz Plug Style Customer to specify which power plug is required in their area at time of order USA 120 VAC EU 220 VAC UK 220 VAC The purifier is supplied configured for operation with one o...

Page 8: ...imum 10 ppm Expected output purity 8N minimum 10 ppb CAUTION The caps fitted to the gas inlet and outlet must be kept on until just prior to installation The length of time that the purifier is left open to the air must be kept to a minimum or the getter material may be prematurely depleted Recommended purge gas Gas to be purified in process Recommended input purity 5N minimum 10 ppm Inlet outlet ...

Page 9: ...ackaging containers and materials such as boxes crates and cushioning outside the clean area Do not tear the polyethylene bag Use a sharp instrument to cut the seal taking care not to damage the item inside the bag Retain the shipping documentation and packaging for future use for example return of the purifier to Servomex for servicing or repair WARNING Argon Ar is a simple asphyxiant Exposure to...

Page 10: ...ier must be installed by a suitably skilled and competent technician or engineer in accordance with this manual WARNING The purifier must be installed and operated in accordance with this and subsequent sections of the manual Failure to do this may cause damage to the purifier and invalidate the manufacturer s warranty WARNING Do not apply electrical power until directed to do so by the start up p...

Page 11: ...SERVOPRO PureGas Gas Purifier 02005001A Revision 0 10 4 1 1 Figure 1 Overall and fixing dimensions Standard ...

Page 12: ...SERVOPRO PureGas Gas Purifier 02005001A Revision 0 11 4 1 2 Figure 2 Overall and fixing dimensions VCR ...

Page 13: ...r open any valves until the inlet and outlet lines are connected and purged WARNING The purging process must be carried out at room temperature Do not switch the purifier on at this stage WARNING Ensure that the pipes to be connected to the purifier are routed so that they do not present a trip hazard to people WARNING Purge and sample gases are asphyxiant in high concentrations Ensure that the pu...

Page 14: ...n integral on off switch A suitable means of externally isolating the electrical supply from the purifier must be provided a suitable switch or circuit breaker must be located close to the purifier clearly marked as the disconnecting device for the purifier The electrical supply coupler or plug must be easily accessible for disconnection from the electrical supply The electrical supply circuit mus...

Page 15: ...erature this takes approximately 3 hours While cooling purge the purifier with inert gas While under purge quickly disconnect the outlet line and replace the outlet cap Next quickly disconnect the inlet line and replace the inlet cap Remove the purifier from the mounting bracket Upon replacement follow the mounting purging and activating instructions WARNING Do not attempt to disconnect any of the...

Page 16: ... clean the outer surfaces of the purifier to prevent the entry of dust or other particulates into the interior of the purifier WARNING The user must not attempt to open the purifier as there are no serviceable parts inside Any attempt to open the purifier would invalidate the warranty on the purifier the purifier may not operate safely or provide reliable data WARNING Liquids must never be applied...

Page 17: ...ial as with any other industrial waste should be performed in accordance with specific local and national laws and regulations The purifier is not suitable for disposal in municipal waste streams such as landfill sites domestic recycling centres and so on Refer to Appendix A2 for disposal requirements in accordance with the WEEE Directive within the EC If the purifier is sent to Servomex or the lo...

Page 18: ...LS IN CONTACT WITH SAMPLE GAS The materials of the parts of the purifier in contact with the sample gas are listed below These materials have a wide range of chemical compatibility and corrosion resistance Purifier for Inert Sample Gas 316 stainless steel 316L stainless steel Zr V Fe alloy ...

Page 19: ...Electrical and Electronic Equipment WEEE Directive The purifier is not intended for disposal in a municipal waste stream but shall be submitted for material recovery and recycling in accordance with the local regulations which implement the WEEE Directive For additional information and advice on the disposal of the purifier in accordance with the WEEE Directive contact Servomex or the local Servom...

Page 20: ...ATION In pursuance of the requirements included in Article 33 of the European REACH Regulation on the Registration Evaluation Authorisation and restriction of CHemicals information on Substances of Very High Concern SVHC contained in Servomex products is provided on www servomex com ...

Page 21: ...4 108 EC o Emissions Class B Equipment suitable for use in domestic establishments and in establishments directly connected to a low voltage supply which supplies buildings for domestic purposes o Immunity Basic Considered appropriate to equipment intended for use in domestic commercial and light industrial environments The purifier complies with the European Community Low Voltage Directive by the...

Page 22: ...SERVOPRO PureGas Gas Purifier 02005001A Revision 0 21 9 5 APPENDIX A5 CONTACT INFORMATION For Global contact details go to our web site www Servomex com and click on contact us ...

Reviews: