manualshive.com logo in svg
background image

REV 05-07-2009

Reverse Osmosis Water Purification System

(Single and Dual Membrane Models)

The MarinePRO

™ RO

 System

INSTALLATION AND OPERATING 

MANUAL

WARNING

Please read carefully before proceeding with installation. Failure to 

follow any attached instructions or operating parameter may lead to 

the product’s failure and possible damage to property.

Содержание MarinePRO RO System

Страница 1: ... Membrane Models The MarinePRO RO System INSTALLATION AND OPERATING MANUAL WARNING Please read carefully before proceeding with installation Failure to follow any attached instructions or operating parameter may lead to the product s failure and possible damage to property ...

Страница 2: ...2 Replacement Optional Parts 23 Warranty 24 TABLE OF CONTENTS Thank You for your purchase of a SpectraPure System With proper installation and maintenance this system will provide you with high quality water for years to come All SpectraPure products are rigorously tested by us for safety and reliability If you have any questions or concerns please contact our customer service department at 1 800 ...

Страница 3: ...n 940 ml min 200 470 ml min 1880 ml min Reverse Osmosis Membrane Feed Water Requirements For the 1 year TFC membrane pro rated warranty to be honored the following conditions must be met Operating Pressure 40 80 psi 2 75 5 5 bar pH Range 3 11 Temperature Range 38 F 100 F 3 C 38 C Maximum Turbidity 1 0 NTU Maximum Silt Density Index 5 0 based on 15 min test time Maximum Chlorine less than 0 1 ppm M...

Страница 4: ...emove organics and chlorine from the feed water that can damage the membrane 3 The final stage of the system is the R O membrane A high rejection Thin Film Composite TFC membrane is used in this system This removes as much as 98 of most inorganic salts all micro organisms and almost all high molecular weight organics in the water SYSTEM DESCRIPTION Fig A Single Membrane Filter Diagram Encapsulated...

Страница 5: ... 4 tubing for easy disconnects Total Chlorine Test Kit TK CL 5 KIT The Chlorine Test Kit contains 10 tablets for ten tests Test the waste water stream for chlorine break through of the carbon block filter Flush Valve Kit VA FVK 4 The Flush Valve Kit is placed between the membrane rejection port and the flow restrictor to provide a high flow by pass used to purge concentrated brine from the membran...

Страница 6: ...blue purified product water tubing into a drain Do not restrict flow from these lines 3 Open the cold water supply valve You may use pressure up to 80 psi 5 5 bar Check the system to ensure that all fittings are tight and leak free before leaving the system unattended If anything is leaking contact SpectraPure for assistance Note It is recommended that at least 2 gallons 7 57 liters of purified wa...

Страница 7: ...must be a minimum of 4X the product flow rate 4X to 6X is an acceptable concentrate flow rate Procedure 1 Collect product water blue tubing into a measuring cup for one minute Measure the collected amount in milliliters Do the same with the waste water yellow tubing WASTE YELLOW IN MILLILITERS______________ DIVIDED BY PRODUCT BLUE IN MILLILITERS______________ The resultant is the Concentrate to Pr...

Страница 8: ...22 9 141 54 10 25 4 136 52 11 27 9 133 50 12 30 5 129 49 13 33 0 128 48 14 35 6 124 47 15 38 1 124 47 16 40 6 PRODUCT RATE CUT TO LENGTH 80 ml min gpd in cm 490 186 1 2 5 460 175 2 5 1 430 163 3 7 6 400 152 4 10 2 379 144 5 12 7 356 135 6 15 2 344 131 7 17 8 326 124 8 20 3 311 118 9 22 9 300 114 10 25 4 289 110 11 27 9 281 107 12 30 5 270 103 13 33 0 263 100 14 35 6 259 98 15 38 1 256 97 16 40 6 P...

Страница 9: ...ollar and thin capillary tubing may then be gently extracted Note Take care not to crush or otherwise damage the delicate capillary tubing 3 Refer to the Flow Restrictor Tables Fig C Find the table that represents the Flow Restrictor Assembly for the system that you have Find the product flow rate in the left hand column and the length of the flow restrictor in the right hand column Example If you...

Страница 10: ...5 mm further into the fitting to completely seat the line into the fitting and O ring seal 7 Turn on the system s water supply and check for leaks prior to further use or testing If a leak is observed you may not have pushed the yellow tubing into the push fitting far enough to seal the tubing against the O ring Turn off the system water supply and re seat the tubing as described above YELLOW TUBI...

Страница 11: ...r tubing black feed water tubing Fig F Dual Membrane Assembly Top Rear View blue purified water tubing Membrane 2 concentrate push fitting yellow concen trate tubing Membrane 1 feed push fitting black membrane feed tubing mounting bracket Membrane 1 Membrane 2 product water tee carbon filter output push fitting blue product water interconnect tubing Membrane 2 feed push fitting black interconnect ...

Страница 12: ...l available water pressure As the filters collect particulates the pressure will begin to drop A 15 20 drop in pressure would indicate that the pre filters are in need of replacement OPTIONAL TDS METER FOR MEMBRANE DI TESTING You can purchase an optional Dual TDS Meter MTR TDS DL1 to determine when the Membrane needs to be replaced Or you can follow 2 simple rules As the hardness of the water buil...

Страница 13: ... will need to be replaced If you remove the sediment and the pressure does not return to normal the carbon filter may be plugged Sediment Pre Filter Replacement Materials Required 1 micron MicroTec Sediment Filter SF MT 1 10 Filter Wrench Procedure 1 Turn off water supply to the system 2 Refer to Fig A B System Pics Using the provided filter housing wrench remove the first housing on the left Unsc...

Страница 14: ...lter can also drop production if its covered with extremely fine sediment If the carbon becomes plugged with sediment it will no longer be able to remove chlorine Carbon Block Filter Replacement Materials Required 1 0 micron Carbon Block Filter CF 1 10 Filter Wrench Chlorine Test Kit TK CL 25 Procedure 1 Turn off water supply to the system 2 Refer to Fig A B System Pics Using the provided filter h...

Страница 15: ...lack line This step allows you to determine the TDS of your tap water See page 9 for removal of push fittings on tee 3 Slowly turn the tap water on and direct the stream to a drain After you get a good flow coming out of the end of the tee you can test the water TAP WATER TDS READING _______________ 4 Once you obtain the tap water TDS reading reconnect the IN Probe back to its original location 5 ...

Страница 16: ...membrane housing lid This may require two people 5 Use a pair of pliers to grasp the membrane stem and pull the membrane from the housing Fig F 6 Remove the black housing O ring Fig F Wash the empty housing with soapy water Rinse thoroughly with hot clean water 7 Insert new membrane into the housing with the double O ring end first Fig G The tube must fit into the recess at the bottom of the membr...

Страница 17: ...low concentrate tubing page 11 from the membrane housing Remove and discard the flow restrictor Fig D 2 Reconnect yellow concentrate tubing back to the membrane housing and run water through system for at least 2 gallons This step will flush out membrane preservatives 3 Disconnect the yellow tubing again and insert the new flow restrictor Follow procedure on page 8 9 for measuring waste to product...

Страница 18: ...SpectraPure SpectraPure Inc 480 894 5437 Call us toll free 1 800 685 2783 2167 East Fifth St Tempe Arizona 85281 18 Notes ...

Страница 19: ... directly proportional to the applied pressure Note The membrane is rated to produce the rated GPD at 60 psi For any pres sure other than 60 psi the output GPD is multiplied by the PCF PCF Line Pressure in psi 60 Calculation of Temperature Correction Factor TCF The output GPD also decreases with decrease in temperature This is because water viscosity increases with decrease in water temperature Te...

Страница 20: ... require a Conductivity Meter TS C61 Procedure 1 Measure tap water conductivity Call it X 2 Run the system for 15 20 minutes 3 Rinse test instrument cell 2 3 times with RO water 4 Measure RO water conductivity Call it Y 5 Subtract RO water conductivity from tap water conductivity X Y 6 Divide this quantity by tap water conductivity X Y X 7 Rejection X Y X 100 Conductivity in the above procedure co...

Страница 21: ... of RO membrane Depending on your tap water chemistry the rejection characteristics of the membrane may vary significantly Method of Calculate Test Results Conclusion Testing Rejection TDS Measure feed water and Is Rejection No Replace Membrane Conductivity RO product water TDS greater than Yes Membrane OK Tester Conductivity 95 Alkalinity Measure feed water and Is Rejection No Replace Membrane Te...

Страница 22: ...ife 1 It is recommended that you store your MarinePRO RO System in a cool place when not being used 2 Your MarinePRO RO System must be protected from freezing or temperatures above 100 F 38 C When considering a location for the installation of the System consider the following factors Light Sources 1 Most of the components of this system are plastic and are subject to damage by ultra violet light ...

Страница 23: ...ment Part SF MT 1 10 1 micron MicroTec Sediment Filter CF 1 10 1 micron Carbon Block Filter MEM 0100 100 gpd 340 lpd Encapsulated TFC Membrane Membrane and Disposable Housing Use 2 for 200 gpd FR 100 Flow Restrictor for 100 gpd System FR 200 Flow Restrictor for 200 gpd System GHA 4 1 4 6 35 mm Garden Hose Adapter XWR UNIV Universal Filter Wrench REPLACEMENT PARTS ...

Страница 24: ...ctraSelect RO membrane elements only for one year from date of receipt by the buyer providing that the loss of performance was not caused by fouling neglect or water conditions exceeding the feed water parameters listed in the applicable product manual refer to detailed membrane warranty information SpectraPure will on confirmation of loss of performance during the warranty period credit the pro r...