The PTU-8 Power Supply Unit has been designed to supply the power to the LLC-8000 system
consisting of 32 student recorders.

Specification

Power requirement

Model for the USA and Canada: 120 V AC
Model for the European countries: 230 V AC
Model for other countries: 110 to 240 V AC

Power consumption

Model for the USA and Canada: 4.5 A
Model for the European countries: 3.5 A
Model for other countries: 600 W

Dimensions

170 

× 130 × 265 

mm (w/h/d) (6

3

×

 

5

1

8

 

×

 10

1

/

2

 inches)

Mass

4.0 kg (8 lb 13 oz)

Rated power output

DC +15 V

Rated current output

DC 24 A (6 A 

×

 4)

Supplied accessories

AC power cord (1)
DC connecting cord (2)
Ground connecting cord (1)
Mounting screws (4)
Operating Instructions (1)

The unit can supply the power up to 32 student recorders, a control console and 4 master recorders.
To supply the power to the student recorders of more than 33 and up to 64, the second PTU-8
should be used.

Design and specifications are subject to change without notice.

PTU-8

 1996 by Sony Corporation

  

Printed in Japan

1

Summary of Contents for PTU-8

Page 1: ...ries 3 5 A Model for other countries 600 W Dimensions 170 130 265 mm w h d 63 4 51 8 101 2 inches Mass 4 0 kg 8 lb 13 oz Rated power output DC 15 V Rated current output DC 24 A 6 A 4 Supplied accessories AC power cord 1 DC connecting cord 2 Ground connecting cord 1 Mounting screws 4 Operating Instructions 1 The unit can supply the power up to 32 student recorders a control console and 4 master rec...

Page 2: ...that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment The shielded interface cable recommended in this manual must be used with this equipment in order to comply with the limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules Keep well ventilated To prevent the temperature from rising inside the unit keep the ...

Page 3: ... 2 DC OUT terminal 3 AC IN connector 1 POWER switch Set the switch to ON to turn on the power 2 DC OUT terminal Outputs the DC power Connect to the control console 3 AC IN connector Connect to an AC power source using the AC power cord supplied Connections and Installation For details of how to install and connect the PTU 8 see the installation manual supplied with the LLC 8000 System Für Kunden i...

Page 4: ...onen ausgesetzt sind Plätze die Magnetfeldern ausgesetzt sind Nähe von Fernseh oder Rundfunkstationen von denen starke elektromagnetische Wellen ausgehen Das Gerät keinen Stößen aussetzen Setzen Sie das Gerät keinen starken Stößen aus und lassen Sie es incht fallen 4 Precaution on Use Safety Precautions Power supply The unit is designed for operation on a power supply meeting the requirements indi...

Reviews: