background image

 

Confidential & Proprietary                    1/39 

HERCULES (Alliance 5W Remote Unit) 

User Manual 

 

 

 

 

 

 

 

  

SOLiD, Inc

 

10,9th Floor, SOLiD Space220 Pangyoyeok-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea 393-400 

 

Tel : +82-31-627-6290    Fax : +82-31-627-6209

 

 

Summary of Contents for HERCULES

Page 1: ...ential Proprietary 1 39 HERCULES Alliance 5W Remote Unit User Manual SOLiD Inc 10 9th Floor SOLiD Space220 Pangyoyeok ro Bundang gu Seongnam si Gyeonggi do Korea 393 400 Tel 82 31 627 6290 Fax 82 31 627 6209 ...

Page 2: ... technical support and or to establish a return authorization for defective units The serial numbers are located on the back of the unit as well as on the box in which they were delivered Additional support information may be obtained by accessing the SOLiD Tehcnology Inc website at www solid co kr or send email at kehan solid co kr This manual is produced by Global Business Division Business Team...

Page 3: ...ote Unit 14 3 3 Dimension 16 Section4 System Installation 17 4 1 Remote Unit Installation 19 4 1 1Remote Unit Enclosure installation 19 4 1 2How to expand ADD ON ROU at the Remote Unit 23 4 1 3Remote Unit Power Cabling 25 4 1 4Remote Unit Ground cabling 26 4 1 5Optical Cabling 28 4 1 6Mounting of MRDU 30 Section5 System Specifications 35 5 1 Physical Specifications 36 5 2 RF performance 37 5 3 Cer...

Page 4: ...stallation 21 Figure 4 5 Connection diagram between Remote Unit and ADD ON ROU DC type 24 Figure 4 6 Location of Ground Terminal 26 Figure 4 7 Information of Terminal 26 Figure 4 8 How to install Ground Terminal 27 Figure 4 9 Location of Optical Connector 28 Figure 4 10 Information of Optical Connector 28 Figure 4 11 How to install Optical Cabling 29 Figure 4 12 Location of MRDU 30 Figure 4 13 How...

Page 5: ...Confidential Proprietary 5 39 Section1 Safety Certification Notice ...

Page 6: ...enerate radio RF signals and continuously emit RF energy Avoid prolonged exposure to the antennas SOLiD recommends maintaining a 300cm minimum clearance from the antenna while the system is operating Do not operate this unit on or close to flammable materials as the unit may reach high temperatures due to power dissipation Do not use any solvents chemicals or cleaning solutions containing alcohol ...

Page 7: ...ase station Round terminals located on the side of a 1 mm2 16 AWG or more wires Using permanently connected to earth green yellow color The following notice The Manufacturer s rated output power of this equipment is for single carrier operation For situations when multiple carrier signals are present the rating would have to be reduced by 3 5 dB especially where the output signal is re radiated an...

Page 8: ...or downlink antenna after accounting for any cable losses should be less than 2 dBi Notice Be careful not to touch the Heat sink part due to high temperature Use of unauthorized antennas cables and or coupling devices not conforming with ERP EIRP and or indoor only restrictions is prohibited Home personal use are prohibited Signal booster warning label message CAUTION DOUBLE POLE NEUTRAL FUSING ...

Page 9: ...Confidential Proprietary 9 39 Section2 Introduction 2 1 Purpose 2 2 HERCULES ...

Page 10: ...ystem uses both analog AMPS and digital TDMA CDMA and WCDMA methods The HERCULES system supports communication standards and public interface protocols in worldwide use Frequencies 700MHz 700MHz_MIMO 850MHz 1900MHz 2100MHz 2100MHz_MIMO etc Voice protocols AMPS TDMA CDMA GSM IDEN etc Data protocols EDGE GPRS WCDMA CDMA2000 Paging LTE etc HERCULES is in modular structure per frequency To provide des...

Page 11: ...e mounted up to 6 in the enclosure Hercules transports signals that multiple operators and multiple technologies are moved at a same time from Base station to a remote location over the same fiber It is available in single and multi band configuration supporting 700M 700M MIMO 850M 800I 900I 700P 800P 1700 2100M 1700 2100MHz MIMO 1900M in parallel It has been specifically tested under a various ai...

Page 12: ...Confidential Proprietary 12 39 Section3 Functional Description 3 1 General 3 2 Compoent of HERCULES Remote Unit 3 3 Dimension ...

Page 13: ...ure 3 1 Remote Unit Block Diagram There are many components R Optic Remote Optical Unit RCPU Remote Central Processor Unit RPSU AC Remote AC Power Supply Unit When using the AC input power RPSU DC Remote DC Power Supply Unit When using the DC input power RDU1 6 Remote Drive Unit CU1 Combining Unit CU2 Combining Unit ...

Page 14: ...The converted RF signals are amplified through High Power Amp in a corresponding RDU combined with Multiplexer module and then radiated to the antenna port When receiving RX signals through the antenna port this unit filters out of band signals in a corresponding RDU and sends the results to Remote Optic Module to make electronic optical conversion of them After converted the signals are sent to a...

Page 15: ... ODU OM4 and ROU 10dBo optical link between ODU OM1 and ROU Fiber Connector SC APC Connector Fiber Type Single Mode Fiber Optical Wavelength 1310 1550 WDM RCPU Remote Central Processor Unit Controls signal of each unit Monitors BIU ODU OEU through FSK communication CU1 Multiplexer CU1 Combine TX signals from 5 RDUs Distribute RX signals to 5 RDUs Furthermore there is reserved RDU slot to support 2...

Page 16: ...Dimension ITEM SPECIFICATION REMARK Size Width Height Depth 320 x 1165 x 260mm Including Bracket Weight 62kg 137lb Fully loaded Power Consumption 510W Fully loaded Operating Temperature 25 to 55 C 13 to 131 F Ambient Temperature Operating Humidity 0 to 90 non condensing ...

Page 17: ...d accessories and tools are list up in the below table Steps for installation Accessories Included Tool Remark Remote Enclosure Installation M12 Bolt 4EA X Spanner 19mm Power Connection_AC AC 120V power cable 1EA 2 meter with MIL 5015 type Connector MS 3106A 18 10S at one end AC Plug at another end Power Connection_DC DC 48V power cable 1EA 2 meter with MIL 5015 type Connector MS 3106A 18 10S at o...

Page 18: ...llation No 1 Screw driver For more details refer to 4 1 6 Connection with ADD ON ROU AC power cable 1 EA 1 5 meter with MIL 5015 type Connector MS 3106A 16 10S and Circular Connector C016_20H003_100_12 by LTW Data Interface cable 1 EA 1 5 meter with MIL 5015 type Connector MS 3106A 14S 5S at both ends RF interface cable 2EA 1 5 meter with N male connector at both ends FAN Unit Option Inner Fan Cab...

Page 19: ...designed to be water and dirt proof The unit has the structure of one Body enclosure It satisfies water proof and quake proof standards equivalent of NEMA4 IP66 Basically Remote Unit is attached with wall mountable bracket Remote Unit can be mounted into either of wall or on a pole Figure 4 1 Exterior of Remote Unit ...

Page 20: ...Confidential Proprietary 20 39 Figure 4 2 Dimension used to install REMOTE UNIT on the WALL ...

Page 21: ...to remove bracket to install enclosure simply after installing 4 of M12 mounting bolts secure 4 mounting bolts tightly First install 2 of M12 mounting bolts roughly half way on the enclosure and install enclosure over the bolts and secure tightly Second install 2 of M12 mounting bolts under the enclosure and secure tightly Figure 4 3 Procedures of installation ...

Page 22: ...O MRDU 2100AWS 1_MIMO ANT2 CU1 Internal Combiner unit for 700 900 850 1900 2100 and 2500 Reserved ANT1 CU2 or CU3 Internal Combiner unit for 700 and 2100 MIMO Internal Combiner unit for 700P 800P and 900I ANT2 Basically the common part of Remote Unit should have an enclosure and it is equipped with RCPU to inquire and control state of each module R_OPTIC to make both of electronic optical and opti...

Page 23: ...ponents additively have 3 item except for enclosure like below Accessories Description Qty Specification Remark 1 TX RF Cable 1 N M ST to SMA M ST_1 5M 2 RX RF Cable 1 N M ST to SMA M ST_1 5M 3 I O Cable 1 IEC 61076 2 101 8pin_F ST_1 5m 4 Power Cable AC type only 1 MIL 5015 16 10_F ST to Circular eco mate 3 PE_M ST_1 5m The following picture shows the connection diagram between Remote Unit and ADD...

Page 24: ...Remote Unit within the proper cable length provided The cables between Remote Unit and ADD ON ROU have each 1 5m length Figure 4 4 Connection diagram between Remote Unit and ADD ON ROU AC type Figure 4 5 Connection diagram between Remote Unit and ADD ON ROU DC type ...

Page 25: ...k if the connection is the same as one seen in the table above and make sure to turn the power ON Provided AC power cable s outlook is below DC Power Remote Unit supports only DC48V of input power Provided outside power cable is only one type The pin discription of DC port is below You should connect exact polarity of DC Port outlook MS Connector numbering Name Description A N C Not Connected B N ...

Page 26: ... bottom of Remote Unit enclosure fixed by M6 screw Compression terminal is attached already when is delivered The recommended thickness of cable is AWG 6 copper grounding wire Figure 4 6 Location of Ground Terminal The specification of compression terminal is like below Figure 4 7 Information of Terminal ...

Page 27: ...s Figure 4 8 How to install Ground Terminal The procedures are 1 Loosen a two M6 screws and then take compression terminal off 2 Insert AWG 6 Grounding Wire into terminal and then compress a terminal using tool 3 Assemble the terminal which made in step 2 using 2xM6 screws 4 Cut the ground wire to proper length and connect it to the earth ground source ...

Page 28: ... Connector is located at the bottom of Remote Unit enclosure fixed Optical Cable can be connected by using connectors Figure 4 9 Location of Optical Connector The specification of compression Optic Connector is like below Figure 4 10 Information of Optical Connector ...

Page 29: ...Confidential Proprietary 29 39 The way to install the Optical cable comply with below procedures The procedures are Figure 4 11 How to install Optical Cabling ...

Page 30: ...ct MRDU cavity duplexer antenna port with CU s designated port Installation Diagram for MROU Module Assembly 1 Install each MRDU into its designated location as shown in the graphic 2 If MRDUs are inserted in slot 5 or 6 install the optional combiner unit CU according to these guidelines Option 1 CU_70B21B Use this unit for combining MRDU_700LTEF_B MRDU_AWS_B Option 2 CU_708090 Use this unit to co...

Page 31: ...ry 31 39 The Remote Unit holds a maximum of 6 MRDUs Guide brackets on the bottom of each MRDU slot simplify installation as described below MRDU installation requires a No 1 tip size screwdriver Figure 4 13 How to mount MRDU ...

Page 32: ...onding slot Tighten the 4 corner screws to secure the unit 4 Install MRDU blank cards in all unused slots in the remote First insert the blank card into the corresponding slot then tighten the captive screw to secure it 4 1 7 How to mount FAN Unit FAN unit is required to be installed on the bottom of the 5W remote as shown in the below figure In the case that MROU temperature on GUI exceeds 70 158...

Page 33: ...Confidential Proprietary 33 39 Figure 4 15 How to mount FAN Unit ...

Page 34: ...able to the FAN Port and connect with the connector located on the top of PSU 3 Install fan unit to the bottom of 5W remote with aligning heatsink pin to the guided groove 4 Secure the fan unit by tightening M6 screw located on the left corner 5 After securing the FAN Unit connect the cable from FAN unit to FAN port ...

Page 35: ...Confidential Proprietary 35 39 Section5 System Specifications 6 1 Physical Specifications 6 2 RF Performance 6 3 Certification ...

Page 36: ...le Fiber connector 1 SC APC for ODU LED Alarm and Status Indicator Power LED TX LED RX LED LD LED PD LED ALARM LED RESET Button AC Power 108 132V AC 50 60Hz DC Power 40 8 57 6V DC Environmental Condition IP Rating IP66 Maximum Power Consumption 510W at full load Enclosure Dimensions mm 320 x 1165 x 260mm Weight Full Load 62kg Optical Data Wavelength TX RX 1310 1550nm Maximum Optical Loss 10dBo Fib...

Page 37: ..._MIMO Single 53 45 39 2110 2155MHz MRDU 900I Single 49 12 39 929 941MHz MRDU 700P 800 Dual 49 49 17 10 39 39 758 775MHz 851 861MHz Uplink Unit naming Description Gain dB Bandwidth MHz output power dBm Frequency range MRDU 850C Single 47 25 5 824 849MHz MRDU 850IC Dual 47 47 7 25 5 5 817 824MHz 824 849MHz MRDU 1900P Single 47 65 5 1850 1915MHz MRDU 700LTE Single 47 47 17 10 5 5 699 716MHz 777 787MH...

Page 38: ...rs il faut choisir le type d antenne et son gain de sorte que la puissance isotroperayonnée quivalente p i r e ne dépassepas l intensité nécessaire à l établissement d une communication satisfaisante RSS GEN Sec 7 1 2 detachable antennas This radio transmitter identify the device by certification number or model number if Category II has been approved by Industry Canada to operate with the antenna...

Page 39: ...ted or operating in conjunction with any other antenna or transmitter RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances RSS 102 RF Exposure L antenne ou les antennes doit être installée de façon à maintenir à tout instant une distance minimum de au moins 300 cm entre la source de radiation l antenne et toute personne p...

Reviews: