Summary of Contents for Sigma Delta

Page 1: ...Sigma δelta Remote Controlled Analogue Mix Engine User Guide Sigma δelta This is SSL www solidstatelogic com ...

Page 2: ...MIDI Software 15 Nucleus Remote Profile 15 Sigma s Internal Software 15 Sigma Remote Control Tablet App 15 4 Network Setup 16 General 16 Sigma s IP Address 16 Useful Built In Features 16 Network Connection Examples 17 System Workflow tips 21 Boot Order 21 Channel Names 21 δelta Plugins 21 Sigma δelta Nucleus Profile 21 SSL Console Transport Master 21 Web Browser Interface 22 Copying Sigma Settings...

Page 3: ...ace Tablet 50 Other DAWs Sigma 52 DAW Sigma Control Surface Tablet 53 Mixing with δelta Control 55 Using DAW Editing Tools 55 For Pro Tools Cubase Nuendo Ableton Live and Logic 55 Other DAWs 55 Third Party Controllers 56 EuCon controllers 56 EuCon Control of the δ Ctrl 16 Plugin 56 Pro Tools EuCon Sigma 56 Logic EuCon Sigma 57 EuCon Control of the Sigma Remote Application 58 Artist Mix Sigma 58 Av...

Page 4: ... Using two Sigmas Together Appendices An overview of Sigma δelta s features Provides information on Sigma δelta s physical connections and how to connect them to your existing studio equipment Lists all the software required to make Sigma δelta work with your DAW Guides you through configuring Sigma δelta to work on your computer network and tablet smartphone Details how to operate Sigma δelta and...

Page 5: ...e δelta Single 16 fader plugins allow Sigma volume mutes mono stereo switching and mix bus routing to be seamlessly incorporated into the DAW workflow volume rides and switching can entered directly as DAW automation but are played out in the analogue domain after processing has been applied as would happen in a traditional analogue mixdown situation The δelta Mix Bus and Monitoring plugins allow ...

Page 6: ... also share the network Setup Concepts Sigma communicates with your computer a little differently to what you may be used to it is worth reading the following all of which is covered in detail in the User Guide before setting up Sigma δelta is an analogue summing unit which can be simultaneously controlled from a cross platform Remote app a DAW via the δelta Control plugins and an MCU compatible c...

Page 7: ...board Sigma δelta Audio Sigma I O Audio Sigma I O MCU Control for Sigma HUI Control for DAW δelta Control Remote App MCU DHCP Server Logictivity Sigma Remote App Network Mac PC I O δelta Control plugin Control Surface Tablet running Sigma Remote app control ...

Page 8: ...EVEL OUTPUTS INPUTS MX 4 16 POWER MADI RATE CLOCK LEVEL OUTPUTS INPUTS MX 16 4 POWER MADI RATE CLOCK LEVEL OUTPUTS INPUTS MX 4 16 Ext input Control surface Ethernet Switch Digital audio Mix outputs from Sigma back into DAW Converters Analogue outboard if present Line level H P feed to live room H P Alt Mon Main Mon Ethernet Router Automation data via Ethernet Tablet via Wi Fi Analogue Audio Analog...

Page 9: ...1 4 jack Important For health and safety reasons do not reboot Sigma with while monitoring through headphones iJack Input stereo external input on 1 8 jack from iPod output or similar device Sigma δelta also provides access to Mix Insert Send Returns a Line Level output for sending headphone feeds into a live room an external input and talkback input all on standard DB 25 connections Access to the...

Page 10: ...ove the power inlet should be used to retain the power lead and so prevent accidental removal or damage rJ45 to connect Sigma to your computer network use a standard Ethernet cable as supplied USB and PrOG access are for SSL diagnostic use only Alternate Monitor Output Main Monitor Output Mix A Output Footswitch Input Clip to secure power cable Factory use only Power Inlet 12V DC Miscellaneous Sen...

Page 11: ...eo insert send signals of both Mix Bus A and Mix Bus B H P Provides a line level stereo headphone output suitable for running a headphone feed into a cue mixer eXT rTNS T B D sub to XLR F Loom ConnectorType 25 way D type Female Pin Description 1 n c XLR 8 14 n c 2 0V 15 Talkback Mic Input ve XLR 7 3 Talkback Mic Input ve 16 0V 4 Mix B Insert Return Right ve XLR 6 17 Mix B Insert Return Right ve 5 ...

Page 12: ...ther the SSL Delta Control dmg disk image Macintosh or the SSL Delta Control Setup zip file Windows included as part of the Sigma downloads these contain the Sigma Remote and ipMIDI applications the plugin installer the Nucleus Remote profile and the latest version of the installation and operating instructions The files can be downloaded from the Update section of SSL s website here Update Please...

Page 13: ...pen the zip file and run the SSL Delta Control Setup exe file follow the installation steps as shown below iLok The plugin uses the industry standard iLok copy protection scheme users will need an iLok2 USB key In the case of a new unit 1 licence is included as standard additional licences are be available from the SSL web store Existing V1 0 3 customers will need to purchase a license from the SS...

Page 14: ...this can be found under the Downloads link for your Sigma Run the installer and follow the same procedure described for the installation of the Single version of δelta We advise running only one type of delta plugin in each DAW session Your Sigma firmware and Remote browser will need updating to version 2 1 0 or above to work with all δelta plugins Both δelta Single and δelta 16 work with the same...

Page 15: ... you are upgrading an older copy of ipMIDI you must uninstall using Add Remove programs it before running the installer NUCLeUS reMOTe PrOFILe In the Nucleus Remote click on Edit Profiles to bring up the Profile Editor popup and click Restore In the pop up which appears locate the file Sigma Delta zip from the software download and click on Open The restored Profile will appear in the Profile list...

Page 16: ...e Ethernet switch in place of an integrated firewall router switch as some of these can not support the high data transfer rate required The NetGear GS108 an eight port switch has been used successfully at SSL Begbroke Sigma s IP Address By default Sigma uses a fixed IP address of 192 168 1 201 Alternatively Sigma can be set to use a dynamically assigned DHCP address if your installation precludes...

Page 17: ...an only use one of those ports at any one time Using Mac Airport and ipMIDI δelta Control If you are using a Macintosh computer you should ensure that Airport is switched off We strongly recommend this as Airport is known to cause conflicts with ipMIDI δelta Control data and may stop Sigma from working If you wish to use the internet we suggest you configure Sigma with a Router Switch see example ...

Page 18: ...in the 192 168 1 X range with a Subnet of 255 255 255 0 X should be a number between 3 and 254 Make sure that the X number is not the same as Sigma s address or any other device on the network Network Connection Configuration windows Go to Network and go into Local Area Connection Properties Open up the option Internet Protocol version 4 TCP IPv4 Select Use the following IP address and then fill i...

Page 19: ...Internet router acts as a DHCP server dynamically assigning IP addresses to all the devices on your network The simplest configuration would be as follows If you have more devices that you need to connect on your network adding an Ethernet switch will allow more things to be connected Internet Ethernet Router Network Connections DAW Computer Internet Ethernet Router Ethernet Switch Control Surface...

Page 20: ...If you are in a studio that has multiple SSL consoles ipMIDI devices we recommend that you purchase one of our LAN integration network switches from the SSL web store Due to the nature of UDP if you have two SSL consoles ipMIDI devices on the same network with a normal router switch setup then you may find that an ipMIDI device in one room will start affecting another ipMIDI devices in another roo...

Page 21: ...t these are inserted and assigned a channel at the beginning of the session Do not copy a plugin to another insert slot once it has been assigned to a channel as this can disrupt the connection to Sigma Using the auto increment feature of the plugin is recommended See section 6 of this User Guide for detailed information on the δelta Plugin Sigma δelta Nucleus Profile A Nucleus Profile is included...

Page 22: ...b It is recommended to re save the settings in the Remote app for further use Translating Sigma v1 0 3 x Automation to the δelta System If you have DAW projects that you wish to continue using with the δelta system the automation data must be translated to the δelta plugin in the DAW Pro Tools HUI View and select the track Volume automation data Edit Copy or Cut Change automation view to SSL δelta...

Page 23: ...OTe APP INTerFACe Once the app is running and connected you have access to all of Sigma s functions The interface is arranged as follows Page 23 Three Buttons for Sigma s Operational Control Buttons for Saving and Recalling Settings ...

Page 24: ...nction with one Sigma to create a parallel compression effect using the compressor s output level to control the amount of compressed signal present Level Control The front panel of Sigma has a blue rotary encoder surrounded by an LED ring Pushing the encoder in will cycle through the options MON H P MIX A and MIX B enabling independent level control of each one MON Main Alternate monitor level H ...

Page 25: ...the output of this stem out of your DAW into the EXT input of Sigma to monitor your printed mix post D A conversion eNGAGe B TO A FUNCTION MIX A OUTPUT ANALOGUe PrOCeSSING DAw INPUT Final Step DAw OUTPUT eXT INPUT OF SIGMA MONITOr eXT INPUT USer Buttons Two User buttons on the front panel allow you to assign up to four functions Each button has a Push and a Push Hold operation By default the User ...

Page 26: ...o receive MIDI CC messages through Follow the on screen instructions to learn un learn functions Assignable MIDI Learn functions include FOOTSwITCH On the rear panel of Sigma you will find a footswitch input suitable for a 1 4 on off latching or non latching footswitch SSL tested with a Digitech FS300 non latching and a standard Marshall guitar footswitch latching By default the footswitch is assi...

Page 27: ...t to 0dB or centre respectively Just above the mix bus buttons you ll see a value in dBs for each channel This is the analogue fader gain readout for each channel and is useful for checking that the DAW s faders are controlling the analogue gains of Sigma Sigma has 2 mix busses A and B Each channel can be routed to either or both busses using the MIX A and MIX B buttons Each channel can be renamed...

Page 28: ...Bus B FADerS 0dB Sets all of Sigma δelta s analogue gains to unity 0dB Useful for restoring Sigma to be a flat summing mixer SOLO SAFe This button enables you to protect channels in Sigma from cutting when a solo is made For instance you may not want your vocal reverb on channel 16 to be cut when soloing the dry vocal on channel 15 To configure a channel as solo safed simply enable the SAFe button...

Page 29: ...e your Sigma δelta unit This will be useful if using more than one Sigma DAw Protocol Selection This must be set in order to allow Sigma to correctly translate automation data from the DAW There are seven options Delta MCU Ableton MCU Pro Tools HUI OSC Cubase Nuendo MCU MIDI Delta is now the default protocol Further information on the MCU HUI protocols can be found in the Sigma V1 manual available...

Page 30: ...Absolute box will become available if MIDI is selected in the DAw PrOTOCOL drop down list MIDI Absolute offers an alternative way of controlling Sigma s analogue gains directly from the DAW Instead of using the δelta control plugin or receiving volume messages over the HUI MCU protocol MIDI Absolute works by receiving MIDI volume messages directly from the outputs of MIDI tracks within the DAW Set...

Page 31: ...is as an AFL bus Sigma will automatically switch the monitor source selection to Mix Bus B when soloing in this mode AFL is useful when you want to solo a channel just to check something whilst printing a mix back into the DAW If you were to use SIP you would disrupt the printing process as soloing in this mode mutes all other channels Please note that if you are operating Sigma in AFL Solo Mode y...

Page 32: ...requent updates provided for Sigma The Nk bin file used to update Sigma s software will be available from the SSL website Login to your SSL account top right hand side of the SSL website and go to the My Products tab You will see a Downloads link next to your registered Sigma listing in this section After downloading the Nk bin file Click on the Software Update button in the SeTTINGS page and loca...

Page 33: ... SAve AND LOAD BUTTONS The SAve button will save all of Sigma s settings across the three main pages MAIN CHANNeLS and SeTTINGS Upon clicking the SAve button you will be presented with a pop up asking you to name the file and choose a destination on your computer network The LOAD button enables you to recall a previously saved Sigma setup Upon clicking the LOAD button you will be prompted to locat...

Page 34: ... the plugin converts the stored automation data from the DAW automation playlists into δ Ctrl messages and routes these back to Sigma via the Logictivity Network connection These automation playlists can be viewed and edited as normal plugin data in the DAW tracks and will be saved alongside the rest of the session data The plugin s data values are expressed in dB units for faders or as text for t...

Page 35: ...ed out when active 4 Mute Switch Indicates the current switch state Click on the switch to toggle console state and to write automation 5 Plugin revision 6 Current Fader Level ABS in dB 7 Fader Click on fader to change level Double click to set to 0dB 8 Fader write Status Activated by clicking on the on screen fader or when a fader on an MCU controller has been touched 9 Channel Label As displayed...

Page 36: ...t to control and write automation 4 Channel Label As displayed in the Remote app or on an MCU controller 5 Mute Switch status indication Click to toggle 6 Solo Switch status indication Click to toggle 7 Fader Click on fader to change level Double click to set to 0dB 8 Fader write Status Activated by clicking on the fader the Remote app gain control or when a fader on an MCU controller has been tou...

Page 37: ... by Command click Mac or Control click PC the Insert Selector and then selecting the SSL plugin from the Other category It will then appear at the top of the Insert Selector pop up menu for fast access Pro Tools Session Setup The final step is to setup the δ Ctrl plugin s δ Ctrl Single Plugin Setup 1 Insert a δ Ctrl single plugin on any track 2 Set the Console Type to SIGMA Console Object to CHAN ...

Page 38: ... is with all switches off and the absolute value of the fader at these are the initial breakpoints stored in the track automation playlists in the DAW When the δelta Ctrl mix system is enabled channels assigned to plugins will be reset to the values stored in the playlists which if no mix data has been saved will be the default settings Double clicking the plugin Fader will reset the Sigma Volume ...

Page 39: ...ote Control app on your computer Once all of these elements are talking open the Sigma Control app on your tablet Control Surface Settings If your control surface can use multiple protocols please ensure that the console is set to MCU protocol for control of Sigma If using a multi layer control surface such as Nucleus ensure that the layer for direct Sigma control is set to MCU in this example lay...

Page 40: ... Both Sigma and the computer must be connected to the switch with Ethernet cables 2 Boot the Sigma unit and the Remote application on the computer 3 Load the Sigma Remote app on the tablet If it appears click on the δ symbol in the center of the screen this will refresh the connection between the tablet app and the computer app You will now have control of the Sigma Remote Master and Channels sect...

Page 41: ... Drag and drop the δ Ctrl plugin on the Top Level item in the left hand pane When you go to enter an Audio FX unit on a track the plugin will appear at the top of the list for quicker entry Logic Session Setup The final step is to setup the δ Ctrl plugin Note that due to the way Logic s automation system works only the δ Ctrl 16 plugin is available for Logic users δ Ctrl 16 plugin Setup 1 Insert t...

Page 42: ...ntrol Surface Settings If your control surface can use multiple protocols please ensure that the console is set to MCU protocol for control of Sigma If using a multi layer control surface such as Nucleus ensure that the layer for direct Sigma control is set to MCU in this example layer 1 Sigma remote Settings 1 Open the Sigma Remote application and go to the Settings page 2 Set Control Protocol to...

Page 43: ...h Sigma and the computer must be connected to the switch with Ethernet cables 2 Boot the Sigma unit and the Remote application on the computer 3 Load the Sigma Remote app on the tablet If it appears click on the δ symbol in the center of the screen this will refresh the connection between the tablet app and the computer app You will now have control of the Sigma Remote Master and Channels sections...

Page 44: ...The SSL δ plugin will appear at the top of the directory and is therefor quicker to add to your session particularly when using the Single plugin Cubase Nuendo Session Setup The final step is to setup the δ Ctrl plugin s δ Ctrl Single Plugin Setup 1 Insert a δ Ctrl single plugin on any track 2 Set the Console Type to SIGMA Console Object to CHAN and Console Object Number to 1 Ctrl click on the Con...

Page 45: ... tracks you can now automate Sigma using the Pro Tools automation system The default state of the plugin is with all switches off and the absolute value of the fader at these are the initial breakpoints stored in the track automation playlists in the DAW When the δelta Ctrl mix system is enabled channels assigned to plugins will be reset to the values stored in the playlists which if no mix data h...

Page 46: ...mote Control app on your computer Once all of these elements are talking open the Sigma Control app on your tablet Control Surface Settings If your control surface can use multiple protocols please ensure that the console is set to MCU protocol for control of Sigma If using a multi layer control surface such as Nucleus ensure that the layer for direct Sigma control is set to MCU in this example la...

Page 47: ...ase note that both Sigma and the computer must be connected to the switch with Ethernet cables 2 Boot the Sigma unit and the Remote application on the computer 3 Load the Sigma Remote app on the tablet If it appears click on the δ symbol in the center of the screen this will refresh the connection between the tablet app and the computer app You will now have control of the Sigma Remote Master and ...

Page 48: ...der to On When inserting a plugin on a track the Favourite Plugins folder will appear in the Ableton plugins directory therefore the SSL δ plugin will be quicker to add to your session particularly when using the Single plugin Ableton Live Session Setup The final step is to setup the δ Ctrl plugin s δ Ctrl Single Plugin Setup 1 Drag a δ Ctrl single plugin onto any track 2 Set the Console Type to S...

Page 49: ...ault state of the plugin is with all switches off and the absolute value of the fader at these are the initial breakpoints stored in the track automation playlists in the DAW When the δ Ctrl mix system is enabled channels assigned to plugins will be reset to the values stored in the playlists which if no mix data has been saved will be the default settings Double clicking the plugin Fader will res...

Page 50: ...te Control app on your computer Once all of these elements are talking open the Sigma Control app on your tablet Control Surface Settings If your control surface can use multiple protocols please ensure that the console is set to MCU protocol for control of Sigma If using a multi layer control surface such as Nucleus ensure that the layer for direct Sigma control is set to MCU in this example laye...

Page 51: ...witch Both Sigma and the computer must be connected to the switch with Ethernet cables 2 Boot the Sigma unit and the Remote application on the computer 3 Load the Sigma Remote app on the tablet If it appears click on the δ symbol in the center of the screen this will refresh the connection between the tablet app and the computer app You will now have control of the Sigma Remote Master and Channels...

Page 52: ...orresponding δ Ctrl plugin It is recommended that the δ Ctrl plugins are added to channels with the corresponding output to Sigma for example the δ Ctrl plugin that controls channel 4 of Sigma added to the insert of the Pro Tools audio track routed to output 4 on your audio interface This is useful for writing automation over the waveform of the audio track 4 Make sure that your track automation s...

Page 53: ...Remote Control app on your computer Once all of these elements are talking open the Sigma Control app on your tablet Control Surface Settings If your control surface can use multiple protocols please ensure that the console is set to MCU protocol for control of Sigma If using a multi layer control surface such as Nucleus ensure that the layer for direct Sigma control is set to MCU in this example ...

Page 54: ...hat both Sigma and the computer must be connected to the switch with Ethernet cables 2 Boot the Sigma unit and the Remote application on the computer 3 Load the Sigma Remote app on the tablet If it appears click on the δ symbol in the center of the screen this will refresh the connection between the tablet app and the computer app You will now have control of the Sigma Remote Master and Channels s...

Page 55: ... standard DAW automation tracks all the DAW editing tools are available for use with the saved automation For Pro Tools Cubase Nuendo Ableton Live and Logic A very powerful feature of δelta Control is that the plugin stores its volume data in the track using the same dB law as the DAW fader volume data This means that the automation copy paste edit commands in the above DAWs allow you to copy DAW ...

Page 56: ...PT Control iPad app For an Artist Mix or PT Control iPad app with 8 faders there are six pages of parameters Avid S3 For an S3 with 16 faders there are 3 pages of parameters The Artist Mix and the S3 both have a fader FLIP function so that the fader can be used to control Sigma levels instead of the encoder Note the encoder is touch sensitive so can be used with the touch automation status to ente...

Page 57: ...ch either contain all 16 channels or the parameters for channels 1 8 followed by a subsequent page for channels 9 16 The pages are in the following order Switches are controlled as variables The OFF state is the encoder fully closed Any level above OFF activates the function Note For Cut it is the OFF state that turns on the Cut switch Volume Trim Pan Cut Mono Mix A Mix B Solo Page 57 Control 1 2 ...

Page 58: ... From the Applications Finder window drag the SSL Sigma Remote App into the list area Set the Protocol to MackieControl and the MIDI ports to 1 4 as shown below Once the Sigma Remote Control App has been placed in the list a system restart is required PC The Avid documentation makes no reference to this set up on a PC however there is a Eucon Control Panel for configuring EUCON Apps where the Sigm...

Page 59: ...e focused application the Artist Mix will be controlling the DAW instead of Sigma if EuCon control has been enabled in the DAW software this happens by default in Logic X It is possible to lock the Artist Mix to the Sigma Remote application via the EuControl Settings app Open the Assign tab in the Setting app then select the Sigma Remote as the open application and finally enable the Entire Surfac...

Page 60: ...he current open application the S3 will be controlling Sigma Channels 1 16 Just as with the Artist Mix when the DAW window becomes the focused application on the computer the Avid S3 will switch to control of the DAW instead of Sigma if EuCon control has been enabled in the DAW software To lock the S3 to the Sigma Remote application follow the setup described for Artist Mix as detailed previously ...

Page 61: ...ther Controllers PreSonus FaderPort Sigma In the Sigma Remote Control App SETTINGS page choose FaderPort for Channels 1 8 and Unassigned for Channels 9 16 Select MCU mode on the FaderPort by holding the Stop key until the Output key flashes then select Output to enable MCU mode The Channel Select and keys scroll the FaderPort up and down the Sigma channels pressing the Bank key followed by the arr...

Page 62: ...bus and monitor settings will be stored within each DAW project for faster recall GUI workstation Setup 1 Follow the steps outlined in the Example Setups for Sigma and your chosen DAW 2 Once the plugin has been installed insert the δ Mix Bus plugin into any track in your DAW 3 The plugin will connect to Sigma automatically Set the track automation type to touch or latch to automate mix bus levels ...

Page 63: ... buttons these buttons switch monitor cut dim and mono as well as switching to the alternate speaker output ALT L S Click on switches to toggle 4 Headphone Source Buttons these buttons switch the headphone output source between Mix A Mix B and the external input Click on switches to toggle between sources 5 Headphone level adjusts headphone level Click and drag mouse to alter level 6 Level Indicat...

Page 64: ... 1 201 Sigma 2 192 168 1 202 or if your switch is able to use DHCP All ip addresses will be automatically assigned to devices on the network when set to DHCP Set Sigma 1 to Delta MCU control from the Sigma Remote application Set Sigma 2 to another control protocol from the legacy web browser interface More details on how to set this up can be found in the legacy Sigma manual available here http ww...

Page 65: ...n Description 1 n c XLR 8 14 n c 2 0V 15 Talkback Mic Input ve XLR 7 3 Talkback Mic Input ve 16 0V 4 Mix B Insert Return Right ve XLR 6 17 Mix B Insert Return Right ve 5 0V 18 Mix B Insert Return Left ve XLR 5 6 Mix B Insert Return Left ve 19 0V 7 Mix A Insert Return Right ve XLR 4 20 Mix A Insert Return Right ve 8 0V 21 Mix A Insert Return Left ve XLR 3 9 Mix A Insert Return Left ve 22 0V 10 Exte...

Page 66: ...ve 0V Chassis Headphones Connector Type 0 25 Stereo Jack Description Tip Signal Left Ring Signal Right Sleeve 0V Chassis Alternate Monitor Output Connector Type XLR 3 pin Male Pin Description 1 0V Chassis 2 Signal ve 3 Signal ve Mix A Output Connector Type XLR 3 pin Male Pin Description 1 0V Chassis 2 Signal ve 3 Signal ve Foot Switch Input Connector Type 0 25 Stereo Jack Description Tip Signal Ri...

Page 67: ...APPeNDIX B SIGNAL FLOw BLOCk DIAGrAM Page 67 ...

Page 68: ... for the entire SSL range is always available through our online support site www solidstatelogic com support If you can t find the answer or solution for your particular issue questions and queries can be submitted to our support staff Page 68 ...

Page 69: ...e ipMIDI software which allows Sigma to work with your DAW Sigma s Internal Software The Software Update button is used to update Sigma s internal software The currently installed software version is shown below the button You will need to have the Ethernet cable connected to perform the update Login to your SSL account here User Login and then select the My Products tab You will see a Downloads l...

Page 70: ...replacing Sigma s hardware Revision 1 0 Sheet 1 of 1 Sigma Internal Wiring Diagram Drg No Symbol Key Connector Label name Analogue Audio Digital Data 629160X1 Main Card 629160X1 Connector Card PL1B PL3B PL1A PL3A PL5 PL7 SK5 SK7 626140X1 CPU 629161X1 Jack Card PL2B 629161X1 Display Card PL2A Page 70 ...

Page 71: ...g All units should be shipped to Solid State Logic in suitable rigid packaging Solid State Logic cannot be held responsible for any damage caused by shipping units in other packaging In such cases Solid State Logic will return the unit in a suitable box which you will be charged for Do not include the power cable manual or any other items Solid State Logic can not guarantee to return them to you P...

Page 72: ...ed No part of this publication may be reproduced in any form or by any means whether mechanical or electronic without the written permission of Solid State Logic Oxford OX5 1RU England As research and development is a continual process Solid State Logic reserves the right to change the features and specifications described herein without notice or obligation Solid State Logic cannot be held respon...

Reviews: