Sliding Gate Opener 

Model:  DKC400Y 

 

 

 

Installation Manual 

  

 

 

 

 

 

 

 

 

WARNING

 

 

Read and thoroughly understand all instructions before installing or 
operating this automatic gate opener. Failure to do so may cause serious 
injury or death. This gate opener produces a high level of force. Stand 
clear of the gate opener during operation and always be aware of the 
hazards associated with it. 

 

Summary of Contents for DKC400Y

Page 1: ...ner Model DKC400Y Installation Manual WARNING Read and thoroughly understand all instructions before installing or operating this automatic gate opener Failure to do so may cause serious injury or dea...

Page 2: ...6 Connecting 9 Wiring notes for control board 11 Control 13 Adding extra remote controls Learn 14 Erase remote controls 14 Verify open direction 15 Set auto close function 15 Cancel auto close functi...

Page 3: ...eventing accidents WARNING any repair or adjustment of working machinery is strictly prohibited unless all the necessary precautions electrical supply disconnected and motor off have been taken in ord...

Page 4: ...ts up to 100 remote controls User programmable and user erasable remote codes Infrared terminal N C is supplied to use Auto close function Pedestrian mode Manual key release design for emergency purpo...

Page 5: ...Limit switch Magnetic or Spring limit switch Remote Control Single Button Mode Auto Close Time 0 45 sec Noise less than 62dB Working Time 90 sec 4 Working principle and main structure The device is co...

Page 6: ...ld be installed on the inside of the gate Gate preparation Be sure the gate is properly installed and slides smoothly before installing the gate operator The gate must be plumb level and move freely M...

Page 7: ...r operation Anchors You can use the anchors bolts washers and nuts that are provided with the operator These anchors must be set into the concrete when it is poured You can also use other ground ancho...

Page 8: ...ded safety it is recommended that limit devices such as a ground stop be placed at both ends of the gate to prevent the gate from sliding out of its rails This is only a precaution the gate operator a...

Page 9: ...DKC400Y Installation Manual v1 1 page 9 of 22 10 15mm Magnet Gate Nut Rack Gear Guide rail 122mm Magnetic limit switch inside Fig 4 Fig 5 6 Connecting Make sure that the power is OFF before making an...

Page 10: ...DKC400Y AC Sliding Gate Installation Manual www solavis com au Copyright 2008 SOLAVIS Doc DKC400Y Installation Manual v1 1 page 10 of 22 Fig 6 Control board scheme...

Page 11: ...rmally open three button mode T Stop G Close K Open COM Common Button switch Control board terminal X10 T G K COM COMMON STOP CLOSE OPEN T G K COM N O Schematic diagram Wiring diagram Single button sw...

Page 12: ...COM CL MOTOR REED SWITCHES SWITCH W V COM U OPEN COM CLOSED RELEASE X9 Wiring diagram 10 Output power supply 12V DC 12V COM CO DET Loop detector I R Infrared N C COM GND 12V Out COM I R COM 12V Termin...

Page 13: ...U V W SWITCH REED SWITCHES MOTOR CL COM OP U C C V W E Motor wiring terminal Control board X2 Wiring diagram 20 Power Input E Earth L Live N Neutral DKC400Y AC220 DKC400UY AC110V Control The remote co...

Page 14: ...LED2 will flash once the beeper will ring for about 1 second Then press the remote control button which you want to use the LED2 will flash on and off again and the beeper will ring for about 2 secon...

Page 15: ...ndition DO NOT leave it in this position for normal operation OFF Normal In this position the control board can be normally used Set auto close function This feature can be selected to make the gate s...

Page 16: ...n DIP switch 3 to OFF position immediately Thus the auto close function has been canceled Pedestrian mode Pedestrian mode can be used to open the gate partially to allow pedestrian traffic to enter Se...

Page 17: ...turn DIP switch 3 to OFF position immediately The auto close function of pedestrian mode has been set Note the new width of the pedestrian mode entry has been re programmed in the device and replaced...

Page 18: ...the gate stop at its closed position automatically if the limit switch is reached After this setup is complete return DIP switch 3 to OFF position immediately Note the new auto close time for pedestri...

Page 19: ...in the event of an obstruction this means that the sensitivity has not been adjusted properly For example if the gate fails to stop the sensitivity might not be high enough to recognize that there is...

Page 20: ...llation Manual v1 1 page 20 of 22 Maintenance Keep operator clean at all times Ensure the operator is well earthed and correctly terminated Regularly grease the wheels and axles to ensure the gate mov...

Page 21: ...the gate will automatically close immediately The auto close time is too short Reset the auto close time See Set auto close function section When you use button 4 of remote control to open the gate th...

Page 22: ...n you open the gate by using button 1 button 2 or button 3 which has been programmed the gate will stop in mid way or reverse before reaching the fully open position The Force Adj VR1 auto reverse fun...