PRODUCT NAME 

 

Solid State Auto Switch

 

 

MODEL / Series / Product Number 

 

D-M9

∗∗

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for D-M9 Series

Page 1: ...No D S OMG0002 E PRODUCT NAME Solid State Auto Switch MODEL Series Product Number D M9 ...

Page 2: ... Instructions 2 Model Indication and How to Order 8 Summary of Product parts 9 Definition and terminology 10 Mounting and Installation 11 Installation 11 Maintenance 12 Troubleshooting 13 Specification 17 Specifications 17 Dimensions 18 ...

Page 3: ... of equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembly operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced 3 Do not service or attempt to r...

Page 4: ...lity a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalogue for the particular products 2 Vacuum pads are excluded from this 1 year warra...

Page 5: ...rate in an atmosphere containing flammable or explosive gases Fire or an explosion can result This product is not designed to be explosion proof If using the product in an interlocking circuit Provide a double interlocking system for example a mechanical system Check the product regularly for proper operation Otherwise malfunction can result causing an accident The following instructions must be f...

Page 6: ...ed Refer to Mounting and Installation on page 11 Be sure to ground terminal FG when using a commercially available switch mode power supply Never mount an actuator equipped with Auto switch in a location that will be used as a foothold The product may be damaged if excessive force is applied by stepping or climbing onto it Do not drop hit or apply excessive shock over 1000 m s2 to the Auto switch ...

Page 7: ...ven for a short time it may be adversely affected insulation failure malfunction due to swelling of the potting resin or hardening of the potting resin or hardening of the lead wires Do not use the product in an environment where corrosive gases or fluids could be splashed Otherwise damage to the product and malfunction can result Do not use in an area where surges are generated If there is equipm...

Page 8: ...e supplied air exhaust the residual pressure and verify the release of air before performing maintenance There is a risk of unexpected malfunction Perform regular maintenance and inspections There is a risk of unexpected malfunction Do not touch the terminals while the power is on Otherwise malfunction and damage to the product can result Do not use solvents such as benzene thinner etc to clean th...

Page 9: ...mm Half strip P 3 wire PNP M 1000 mm Half strip B 2 wire L 3000 mm Half strip Z 5000 mm Half strip Electric entry SAPC 500 mm M8 3 pin pre wired Symbol Specification SBPC 500 mm M8 4 pin pre wired NIL In line SDPC 500 mm M12 4 pin pre wired V Perpendicular MAPC 1000 mm M8 3 pin pre wired MBPC 1000 mm M8 4 pin pre wired MDPC 1000 mm M12 4 pin pre wired ...

Page 10: ... 9 No D S OMG0002 E Summary of Product parts Summary of Product parts D M9B M9N M9P D M9BV M9NV M9PV ...

Page 11: ...e position The center position of the sensor unit which gets the strongest reaction of the sensor unit which means the center position of an operating range as well N NPN output Auto switch which sinks current from the signal line when turning on P PNP output Auto switch which sources current from the signal line when turning on R Reed Auto switch Auto switch which generates on and off outputs wit...

Page 12: ...r whose grip diameter is 5 to 6 mm when tightening the mounting screw M2 5 mount screw tightening torque shall be 0 05 to 0 15 Nm 0 5 to 1 5 kgf cm Setting the detection position Position the actuator at the end of the stroke Set the Auto switch in the position where the Auto switch Red light is ON Detecting actuator end Based on A and B dimensions in the actuator catalogue set the Auto switch pos...

Page 13: ...onnector Maintenance After the power has been disconnected please observe the following precautions Regarding the actuator operation set up the contents of the program may be maintained by the customer s application system Take care to confirm safety when the power is re connected and the actuator operation is resumed because the operation may have stopped in an unstable condition ...

Page 14: ...n on The operation LED doesn t light up The operation LED doesn t go off Is the actuator applicable Product failure Product failure Misapplication Trouble No 4 Normal Trouble No 6 The operation LED doesn t light up The operation LED doesn t go off Trouble No 1 The switch doesn t detect normally The operation LED doesn t go off The operation LED doesn t light up The switch output doesn t turn off T...

Page 15: ...ct wiring 2 wire Reverse connection of wiring brown and blue Correct wiring Refer to Internal circuit on page 12 2 The switch output doesn t turn off The operation LED doesn t light up Product failure 3 wire Replace the product Mismatch the load current specification 2 wire Satisfaction of the following relations by the load current specification Load voltage is ON level Current leakage x n x load...

Page 16: ...ing torque 0 05 to 0 15 Nm Displacement of the actuator stopping angle Deviation of the actuator stopping angle position Stabilize stop position The presence of magnetic filed source near the actuator electric welding machine conductor and strong magnet etc Place a magnetic shield plate between magnetic filed source and the actuator The effect of magnetic field generated by adjacent actuator place...

Page 17: ...nit or switch mounting screw Fix to proper position at appropriate torque Tightening torque 0 05 to 0 15 Nm Incorrect wiring Condition of connected part connector contact pin and crimping terminal Correct wiring Perform wiring of connected part again Breakage of lead wire The presence of repeated bending stress to a part of lead wire bending radius tensile force to the lead wire Correct wiring Adj...

Page 18: ...to 40 mA Internal voltage drop 0 8 V or less at load current of 10 mA 2 V or less at load current of 40 mA 4 V or less Current leakage 100 µA or less at 24 VDC 0 8 mA or less Operating time 1 ms or less Indication light Operating position The Red LED lights up Electrical entry Grommet Lead wire Vinyl sheath cable 2 7 x 3 2 oval 0 15 mm2 2 wire D M9B V 3 wire D M9N V D M9P V Impact proof 1000 m s 2...

Page 19: ... 18 No D S OMG0002 E Dimensions D M9B N P D M9BV NV PV ...

Page 20: ... RQ 5 5 6 6 6 7 9 5 10 11 MXH 3 3 5 5 6 MXU 3 3 5 4 5 MXS 3 3 3 4 5 5 5 5 MXQ 3 3 3 5 4 5 4 5 5 5 MXF 3 3 4 5 5 MXW 3 5 3 5 5 6 5 5 MXP 3 3 3 5 3 3 MY1B 4 4 5 5 5 MY1M 9 8 5 MY1C 7 5 7 5 MY1H 3 5 4 5 5 5 MY1 W 8 8 CXT 3 4 5 5 5 5 6 6 CLQ 3 4 4 5 4 5 5 5 5 6 6 5 7 7 5 REBR 4 5 MK 3 4 6 5 5 5 6 5 6 5 MK2 6 5 5 5 6 5 6 5 RSQ 3 6 6 7 CEP1 3 4 CE1 6 6 6 7 1 It is not for guarantee but measure including...

Page 21: ...5 7 MIW 3 2 5 4 5 5 7 RZQ 6 5 5 6 6 5 MY3 4 6 8 5 8 5 MXY 3 5 3 5 3 5 MXJ 2 5 2 5 2 5 CY1R 5 6 5 4 5 5 5 CUJ 3 3 5 3 5 CY1F 5 5 6 6 ZCUK 4 5 7 7 7 RLQ 5 5 5 5 5 7 XL 4 5 4 5 5 5 6 5 7 8 9 9 XM 4 5 4 5 5 5 6 5 7 8 9 9 XY 4 5 4 5 5 5 6 5 7 8 9 9 1 It is not for guarantee but measure including hysteresis Dispersion is approx 30 It might be changed drastically depending on the ambient Series Bore size...

Page 22: ...mm 6 8 10 12 15 16 20 25 30 32 40 50 63 80 MHZ2 0 5 0 5 0 8 0 5 0 5 MHR2 0 5 0 5 0 5 0 5 MHR3 0 5 0 5 MHK2 0 3 0 5 0 5 0 5 MHS2 0 5 0 5 0 5 MHS 3 0 5 0 5 0 5 0 6 0 6 0 6 0 6 0 6 MHS4 0 5 0 5 0 5 MHT2 3 3 3 3 MHC2 0 5 MHF2 0 5 0 5 0 5 0 8 Unit Angle 6 8 10 12 15 16 20 25 30 32 40 50 63 80 2 2 2 2 MHY2 4 4 3 3 1 It is not for guarantee but measure including hysteresis Dispersion is approx 30 It migh...

Page 23: ...30 24 22 19 14 CRJ 45 40 Unit Hysteresis mm 0 5 1 2 3 7 10 15 16 20 25 30 40 50 70 100 200 MRHQ 0 5 0 6 0 5 0 6 1 It is not for guarantee but measure including hysteresis Dispersion is approx 30 It might be changed drastically depending on the ambient 2 Please contact SMC sales division regarding another models Series Bore size Series Bore size ...

Page 24: ...product spec C Modify the contents D Modify the contents E Limited warranty and Disclaimer are added URL http www smcworld com 4 14 1 Sotokanda Chiyoda ku Tokyo 102 0021 Japan Tel 81 3 5207 8249 Fax 81 3 5298 5362 Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer 2008 2013 SMC Corporation All Rights Reserved ...