QUICK INSTALLATION GUIDE

SMARTOPTICS DCP-SERIES

Before using the product, be sure to read the safety chapter and more 
detailed information in the full installation manual. For full manual, 
contact [email protected].

© Copyright Smartoptics 2016

DCP-2 
Chassi

Slot A

Slot B

Redundant 

power supply

Communication

ports

Redundant 

power supply

DCP-2

fan

COMMUNICATION INTERFACES

There are two ways to communicate with the unit:
-  Through one of the five ethernet ports, using SSH
-  Through the console port, using serial communication

Default login is
Username:  

admin

Password: admin

ETHERNET

All the communication ports are located on the back of the unit, DCP-2.

The factory default IP settings are
Eth local: 

192.168.0.1

Eth1-4: 192.168.1.1
Netmask: 255.255.255.0

CONSOLE PORT

Serial communication: Connect the serial port of the DCP-2 to a DB9 port 
on the computer, or a USB port, using a DB9/USB converter.

Use the following settings for the serial transaction
Baud Rate: 

115200

Data Bits: 

8

Parity: None
Stop Bits: 

1

Flow Control: 

None

GENERAL PURPOSE CLI COMMANDS

SETUP

Type ‘

setup

’ and then enter the new configuration parameters as 

requested, using the format indicated in between parenthesis or just 
press enter to leave the parameter unchanged

SHOW STATUS

Show the status of the unit

SHOW ALARM 

There are two alarm commands ‘

show alarm active

’ or ‘

show alarm 

log

’.

SO_DCP_R4.0