SMART MAX GEOSYSTEMS

 

DE2A & DE2A-L Theodolite Manual 

 

Summary of Contents for DE2A

Page 1: ...SMART MAX GEOSYSTEMS CO LTD www smartmaxgeosystems com info smartmaxgeosystems com SMART MAX GEOSYSTEMS DE2A DE2A L Theodolite Manual...

Page 2: ...trument by yourselves 5 Prohibit to see the sun with telescope 6 Cover with umbrella in burning sun or rainy day 7 Cover the instrument with rainy cover 8 Power off before taking off battery or the da...

Page 3: ...rement Preparation 7 3 1 Instrument Setting Up 7 3 2 Instrument Leveling 7 3 3 Centering with Optical Plummet 9 3 4 Eyepiece Adjustment and Object Sighting 9 3 5 Power on 10 3 6 Power off 10 4 Angle M...

Page 4: ...g Up 22 8 1 Enter into Setting up Parameter 22 8 2 Setting up Parameter 23 9 Check Adjustment 24 9 1 Check Adjustment of Plate Vial 24 9 2 Check Adjustment of Circular Vial 26 9 3 Check Adjustment of...

Page 5: ...of All Parts 1 1 Name of Parts 1 Telescope 2 Main body 3 Left Side Cover 4 Series No 5 Optical Plummet 6 Circular Vail 7 Leveling Screw 8 Tribrach 9 Connection Knob on Tribrach 10 Soft Key 11 Display...

Page 6: ...www smartmaxgeosystems com info smartmaxgeosystems com 2 17 Handle 18 Handle Screw 19 Battery locking Lever 20 Battery 21 Grip 22 Eyepiece 23 Right Side Cover 24 Horizontal Tangent crew 25 Horizontal...

Page 7: ...characters date and time etc There are two modes on display Measurement Mode Menu Mode Display example Angle Measurement Mode Distance Measurement Mode Remeasurement Mode Menu Mode ANG 08 01 02 12 00...

Page 8: ...Battery Horizontal locked Special Function press twice it will be disappeared Gradient Display b OUT Vertical angle is over the compensation OUT Slope is over 100 m Meter unit Set 360 as angle unit 1...

Page 9: ...f horizontal angle HOLD Hold the horizontal angle Vertical angle percent grade mode 0SET Set horizontal angle as 0 00 00 Distance Measurement Mode REP Power ANG ENT SD HD VD TR Soft Key Function SD En...

Page 10: ...press when it display press Turn on off laser plummet First press when it display press Turn on off LCD First press when it display press ENT Enter into Menu mode press ENT one more time will save an...

Page 11: ...1 Insert recharger into battery s hole 2 Insert the plug of the recharger into 220V AC power supply It shows green light after finishing recharging 3 Cut the power supply of the recharger and drew th...

Page 12: ...The bubble is now located on a line perpendicular to a line running through the centers of the two leveling screw being adjusted b Turn the leveling screw C to bring the bubble to the center of the c...

Page 13: ...check the whether the bubble is correctly centered for all four points 3 3 Centering by optical plummet Adjust the eyepiece of the optical plummet telescope to your eyesight Slide the instrument by l...

Page 14: ...lear with the telescope focusing screw If there parallax when your eye move up down or left right that show the diopter of eyepiece lens or focus is not adjusted well and accuracy will be influenced s...

Page 15: ...ase replace and recharge the battery 3 6 Power off Press the Power key red key 4 Angle Measurement 4 1 Measuring Horizontal Angle Right and Vertical Angle Operation Procedure Display Press ANG to ente...

Page 16: ...pter so that the cross hairs are clearly observed Turn the diopter toward you first and then backward to focus 2 Aim the target at the peak of the triangle mark of the sighting collimator Allow a cert...

Page 17: ...Left Operation Procedure Display Press ANG to enter into Angle Measurement Press L R The mode Horizontal angle Right HR Switches to HL mode Press L R to switch Right mode and Left mode Press ENT the...

Page 18: ...zontal tangent screw Then press HOLD Aim at the target which need to be set up the angle Press the ENT to finish holding the horizontal angle The display returns back to normal angle measurement mode...

Page 19: ...le Measurement Press to enter into Slope Measurement The display mode switches when pressing key every time While the measurement is carried out over 45 100 from the horizontal the display shows OUT 4...

Page 20: ...LTD www smartmaxgeosystems com info smartmaxgeosystems com 16 4 6 Remeasuring Horizontal Angle Operation Procedure Display Press REP to get into the mode of Horizontal Angle Remeasurement 08 01 02 12...

Page 21: ...rizontal angle and it will be saved Aim at the Target A again Press 0SET one time to set the reading of A as 0 00 00 It begins the first remeasurement Aim at the Target B again by Horizontal Tangent a...

Page 22: ...show E 09 if more remeasurement done Press REP and restart When do remeasurement it will display E 08 if Measured Value Average Value 30 Press REP and restart 5 DISTANCE MEASUREMENT Please confirm the...

Page 23: ...press ENT to stop Press HOLD to start HD Measurement while press ENT to stop Press to start VD Measurement while press ENT to stop Press 0SET to start Tracking Measurement while press ENT to stop SD...

Page 24: ...rough the sightline up down or left right in the telescope to measure the distance between the target and the instrument Accuracy 0 4 D Place the instrument at point A and place the leveling staff at...

Page 25: ...t But because of such a low accuracy it can not be used to measure distance which requires high accuracy 7 Laser Measurement 7 1 Orientation Measurement Find out the other points on the line of the tw...

Page 26: ...Angle Designment is based on the line of two points then design a horizontal angle according with the requirement Steps as bellows 1 Leveling the instrument then power on This must be done on a fiduc...

Page 27: ...to make the facula minimum loosenthe horizontal clamp screw move the telescope the geometry center of the facula s movig track is the Vertical Direction 7 4 Level Measurement 1 Leveling the instrumen...

Page 28: ...s Press to set up parameter Continuous press Press ENT to save 8 2 Setting up the Parameters SET 0 Power off Automatically ON The instrument will power off automatically if there is no 08 01 02 12 00...

Page 29: ...he compensator SET 2 Position 0 Vertical Angle ON Zeith is 0 the Horizontal will be 90 when turn left and it will be 270 when turn right OFF Zeith is 90 the Horizontal will be 0 when turn left SET 3 M...

Page 30: ...d place the plate vial parallel with the line connecting leveling screw A and B and then bring the bubble to the center of the plate vial by turning the leveling screws A and B Rotate the instrument 1...

Page 31: ...to the center by adjusting the leveling screw which is parallel to the plate vial Correct the remaining half by adjusting the screw of plate vial with adjusting pin Confirm whether the bubble does is...

Page 32: ...ar vial is not in the center bring the bubble to the center by using the adjusting pin to adjust two bubble adjusting screws 9 3 Check Adjustment of Optical Plummet Check Set the instrument on the tri...

Page 33: ...essary Otherwise the following adjustment is necessary Adjustment Take off protective cover of the optical plummet you may see four adjusting screws Adjust four adjusting screws Move woodscrew to make...

Page 34: ...Reticle Check Set the instrument on a tripod and level it Aim at target A with telescope One point 50m away Observe point A moves along the vertical line of the reticle or not by moving telescope up a...

Page 35: ...ound the sight line and align the vertical line of the reticle with point Tighten the reticle adjusting screws Repeat the inspection and adjustment to see if the adjustment is correct 9 5 Check Adjust...

Page 36: ...R 180 2 If C 8 no adjustment is necessary If C 8 fellow these steps to adjust it Adjustment Rotate fine motion screw in the right position and make the reading is HR C Remove the eyepiece cover to adj...

Page 37: ...il angle value VR Calculating i VI VR 360 2 If i 10 no adjustment is necessary If i 10 adjust it Adjustment Please adjust through the software if the differences between the index is too big Operation...

Page 38: ...was done after finishing the inspection and adjustment of Item 9 4 and 9 5 Laser confocal Send the laser after aiming at the target and then check the facula s diameter It should be minimum If it is n...

Page 39: ...chnical Index Telescope Image Erect Magnification 30 Effective aperture 47mm Resolving power 3 75 Field of view 1 30 26m 1000m Minimum focus Stadia ratio 100 Up tighten screw 1 relax screw 3 Down tigh...

Page 40: ...rcle 79 Minimum reading 1 5 10 20 Selectable Measuring unit 360 400gon 6400mil Selectable Vertical angle Zenith Horizontal Selectable Accuracy 2 5 10 Selectable Vial Plate vial 30 2mm Circular vial 8...

Page 41: ...tage DC6 Operation time BDC 1800mAh about 20 hours Laser Length of the wave 635nm Power 10mW Effective range during daytime 150m Position error with the sight 5 Power DC3 3V Working temperature 10 45...

Page 42: ...STEMS CO LTD www smartmaxgeosystems com info smartmaxgeosystems com 38 Recharger 1pc Plummet 1pc Tool bag 1pc Carrying case 1pc Operator manual 1pc 12 Error Code Instruction E 301 Memory Card Error E...

Page 43: ...martmaxgeosystems com info smartmaxgeosystems com 39 E 303 HJ767 Error E 304 HY767 Error E 305 HJ767 Error AND HY767 Error E 108 Compensator Error E 08 Remeasurment Measured Value Average Value 30 E 0...