Page 1: ...GS361A H04 Radiator Thermostat User Manual SITERWELL ELECTRONICS CO LIMITED www china siter com ...

Page 2: ...k and set the window detection function in APP Any operation at the device side will also be synchronized to APP such as setting temperature manually 2 Features 3 mode settings Automatic mode Manual mode and Anti freezing mode Temperature setting range 5 30 For Automatic mode and Manual mode or 5 15 For Anti freezing mode With LCD display screen and big characters easy to see 2 years battery life ...

Page 3: ...eable batteries 3 After putting into the batteries the current temperature and symbol will be displayed 4 Load the outer case and turn it towards the opposite direction with right hand to complete the installation of batteries 4 2 Start to use You can use your thermostat in only a few steps 1 Press the knob and hold on for 3 seconds before the product be installed on the valve 2 Until the appears ...

Page 4: ... nuts clockwise until tightening The maximum torque is 5N m 4 Press the knob again and appears 5 After about 10 seconds the symbol disappears and the current temperature is displayed The installation is finished In order to minimize the influence of the radiator s own heat on the thermostat it is recommended to install as follows Correct Wrong ...

Page 5: ...ry part of the adjustment process The thermostat will close the radiator valve at a specific time and then opens it again to detect the exact opening position of the valve The automatic detection function can make use of heat as efficiently as possible and control the temperature more accurately If necessary please reload the battery and activate the installation mode and manually run the automati...

Page 6: ...at 17 when sleeping and set at 15 when being away home The automatic mode needs to connect to the gateway and needs network Manual mode Manual mode this temperature you set will not change because of the different situation mode the temperature can be set manually by adjusting the knob and the temperature range is 5 30 Anti freezing mode Anti freezing mode while you leave home for a long time set ...

Page 7: ...hild lock function as shown in the following figure When the child lock function enables all operations on the thermostat will be invalid to prevent children from playing with the thermostat or misoperation because of curiosity Note that setting child lock locally must be done after installation 1 Press the knob and hold on for more than 3 seconds 2 A symbol appears to indicate that the child lock...

Page 8: ...GS361A H04 User Manual V1 06 8 20 5 4 Installation of TuyaSmart APP Scan the QR code as below get and install TuyaSmart APP for IOS and Android system TuyaSmart APP ...

Page 9: ...ng TuyaSmart APP it is necessary to operate the network setting of the Tuya Gateway called TYGWZ 01 1 Login the APP after registration 2 Click Add Device 3 Select Gateway ZigBee 4 Make sure the LED is always on and click to next 5 Wait and until next Interface appears 6 Finished ...

Page 10: ... by pressing the knob three times quickly Matching process is limited to 2 minutes cannot be interrupted halfway and then automatically withdraw 1 Click Add sub device 2 Find out Thermostat ZigBee and click it to match 3 Click the knob 3 times quickly 4 Wait and until next Interface appears 5 Successfully 6 Main page ...

Page 11: ... 20 5 7 Mode selection in APP It supports to switch Automatic mode Manual mode and Anti freezing mode in APP Please refer to the introduction of section 5 1 for the differences between different modes Click or button to set one mode ...

Page 12: ...1 06 12 20 5 8 Set temperature in APP The temperature settings in different modes are supported in APP and the operation can be accomplished by dragging the adjusting ball simply Drag the adjusting ball to set the temperature ...

Page 13: ...led by APP as shown in the following figure When the child lock function is enabled all operations on the thermostat will be invalid to prevent children from playing with the thermostat or misoperation because of curiosity Click the child lock button to enable or unenable the child lock function ...

Page 14: ...the window opening detection function is enabled if the thermostat detects that the window is opened the valve will be closed for 30 minutes to reduce heat loss The window detection function is opened by default If it has been shut down it can be reopened according to the following steps Click on the window button to enable or cancel the window detection function ...

Page 15: ...n the following figure When the valve detection function is opened when necessary it will run its own valve inspection procedures The valve detection function is opened by default If it has been shut down it can be reopened according to the following steps Click on the valve button to enable or cancel the valve detection function ...

Page 16: ...GS361A H04 User Manual V1 06 16 20 5 12 Automatic Mode Settings 1 Click button 2 Click Add timing 3 Set the time and temperature and save 4 Save successfully and click Back 5 Finished ...

Page 17: ...open air Setting temperature Automatic mode 5 30 Manual mode 5 30 Anti freezing mode 5 15 Measurement temperature 0 50 Measurement intervals Once every 2 minutes Valve stroke 6mm max Noise level 35 dBA Environment temperature 0 40 Storage temperature 20 65 Max water temperature 90 Environment standards RoHS Size Φ57 89mm Interface nut M30 1 5mm Weight 192g Include batteries ...

Page 18: ... water pipe 3 APP can t operate the thermostat The thermostat is not connected to the APP Reference section 5 5 The thermostat is far away from the APP or there are multiple obstacles in the middle Adjust control distance Low battery Replace the battery 4 The thermostat can operate normally but the room temperature cannot be kept constant 5 LCD displays 6 After the thermostat is installed on the b...

Page 19: ...S361A H04 User Manual V1 06 19 20 Room area is too large radiator does not match Replace radiator The inlet water pressure or inlet temperature is too low Check inlet water pressure and inlet temperature ...

Page 20: ...that these applications without further modifications are appropriate and that we also have the right to modify the product without any notice For the latest information please refer to our website http www china siter com If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired SITERWELL ELECTRONICS CO LIMITED Address No 666 Q...