Beijing  Sincoheren Science and Technology Development Co. Ltd                                           XKYR-SM-A/2-PL755-01

 

 

 
 
 
 
 

MONALIZA

 

LASER

 

SYSTEM 

 

 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Nd:YAG

 

Laser

 

Tattoo

 

Removal

 

Device

 

 
 
 
 
 

User

 

Manual

 

 
 
 
 
 
 
 
 
 
 
 

Release  Date: 2018-06-25 

 

Execution  Date: 2018-06-25 

 

File  Number: XKYR-SM-A/2- PL755-01 

Beijing  Sincoheren Science and Technology Development Co. Ltd 

Summary of Contents for Monaliza M4C-II

Page 1: ...opment Co Ltd XKYR SM A 2 PL755 01 MONALIZA LASER SYSTEM Nd YAG Laser Tattoo Removal Device User Manual Release Date 2018 06 25 Execution Date 2018 06 25 File Number XKYR SM A 2 PL755 01 Beijing Sinco...

Page 2: ...ology Development Co Ltd XKYR SM A 2 PL755 01 Revision History Version State Date Modifier Description A 0 First edition 2015 12 10 A 1 2016 03 25 Update energy parameter A 2 2018 06 25 Zhangling Prod...

Page 3: ...preparation 6 3 1 1 Requirements 8 3 1 2 Installation Steps 8 3 2 Add Water and Drainage 8 3 2 1 Add Water 8 3 2 2 Drainage 9 4 Operation Guide 10 4 1 Preparation 10 4 2 Start the Device 10 4 3 Opera...

Page 4: ...ged optical components inside the treatment handle great attention shall be present against unexpected falling down 1 Safety matters Considerable thought was given during the design of the system to m...

Page 5: ...e the system in the presence of explosive anesthetics and other flammable materials 3 Better not use metal surgical instruments during the operation against harmful reflection if direct treatment hand...

Page 6: ...avelength is 200 1100nm Never look directly at the light and reflected light even when wearing protective eyewear Gauze protective eyewear and eyelid board are all effective to prevent client s eye fr...

Page 7: ...ndle contains delicate optical components so during the course oftransportation the shock absorbing package originated from the seller must be used Otherwise it may cause malfunction and affect output...

Page 8: ...eijing Sincoheren Science and Technology Development Co Ltd XKYR SM A 2 PL755 01 6 2 Appearance and Technical Parameters 2 1 Appearance The appearance and of this product is shown in Figure 1 Figure 1...

Page 9: ...Weight 24Kg 3 Installation and Commissioning This system can be installed in hospitals medical clinics and beauty salons There is less preparatory work before installation When you purchase our compan...

Page 10: ...ent Co Ltd XKYR SM A 2 PL755 01 6 Table 2 Equipment List No Equipment Quantity Note 1 Host 1 2 Treatment handle 1 3 Treatment head 4 4 Protective glasses 1 5 Eye mask 1 6 Funnel 1 7 water spout 1 8 Po...

Page 11: ...28 Humidity 20 Atmospheric pressure 860hPa 1060hPa Environmental requirements Avoid direct light Cooling water Deionized or purified water Electrical requirements Input voltage AC110V OR AC220V 50Hz...

Page 12: ...offthe power and then fill the water to the maximum level ofthe water tank The cooling water must be changed once a month Note The first time after changing the cooling water each time turn on the de...

Page 13: ...er level observation window to ensure that the water level is above the specified level 2 Check all the system connections 3 The emergency switch is not pressed 4 All personnel in the treatment area h...

Page 14: ...Figure 3 welcome interface 4 3 Operation Process 4 3 1 Program Selection Interface Choose wavelength1064nm 755nm 532nm on the welcome interface to enter the program selection interface as shown below...

Page 15: ...the cabinet 2 After each treatment the treatment head should be cleaned When cleaning first wipe with a soft cloth then use another soft cloth to dip into alcohol and then fully dry 3 Change the cool...

Page 16: ...d pigment particles have enough time to be absorbed 6 3 Treatment times General cases shall be repeated treatment to achieve the ideal effect for the treatment of patients with specific times by the a...

Page 17: ...y reaction After the surgery the treatment site will be frozen 3 For some containing metal ions such as iron ion pigment can appear after laser irradiation is not easy to be absorbed in black chemical...

Page 18: ...rators must be trained Non trained personnel are not allowed to operate machines 3 The company shall not be responsible for any medical accident or dispute caused by the failure to read the manual or...

Page 19: ......