background image

ENGLISH

R3016 12U/6X

Installation Manual

www.navico.com/commercial

Содержание R3016 12U/6X

Страница 1: ...ENGLISH R301612U 6X Installation Manual www navico com commercial...

Страница 2: ......

Страница 3: ...y The warranty card is supplied as a separate document In case of any queries refer to the brand website of your display or system www navico com commercial Regulatory statements This equipment is int...

Страница 4: ...before starting to work Have these operating instructions always at hand on all relevant locations and ensure that copies are available to all operators Operating personnel must at all times follow a...

Страница 5: ...Transceiver 6 ft antenna 0 05 0 9 The system is however designed to always disable the microwave radiation when the antenna is not rotating X Ray radiation This radar system does not generate X ray r...

Страница 6: ...he SI80 22 Wiring 22 General precautions 22 System overview diagram 22 Up mast transceiver cables 23 Up mast transceiver grounding 23 Connection at the up mast transceiver 24 Transceiver power supply...

Страница 7: ...le at the product web site www navico com commercial System components The R3016 Control unit The R3016 Control unit includes 3 main components a processor a monitor and a keypad The processor is made...

Страница 8: ...is made via NMEA 2000 The SI80 provides power and termination for the backbone R3016 12U 6X manuals The following documentation is delivered with the R3016 12U 6X Radar system R3016 12U 6X Operator ma...

Страница 9: ...sconnect power to transceiver circuits excludes heater 5 Ground terminal post Mandatory grounding connection point for connection to vessel ground R3016 ontrol unit connectors ETHERNET HDMI NMEA2000 P...

Страница 10: ...eld connection point 4 ON OFF supply switch Disables output from supply 5 Negative input Negative return for power input 6 Positive input 24 VDC power input 7 Fuse Protects supply from output overcurr...

Страница 11: ...determined to be fit for purpose capable of supporting the radar in any weather or sea state Interference Other radar Do not install the radar transceiver on the same beam plane as other radar provid...

Страница 12: ...een the swing circle turning radius and the other installed objects Blind sectors It should be kept to a minimum and not occur in an area of the horizon from right ahead to 22 5 abaft the beam to eith...

Страница 13: ...be such that the user is looking ahead The lookout s view should not be obscured and any ambient light should cause minimum degradation on the display screen in accordance with MSC Circ 982 Tools requ...

Страница 14: ...ed until immediately prior to antenna fitment Note While the up mast transceiver is fitted with mounting studs to cater for common installation scenarios it may be required to fit different studs or b...

Страница 15: ...n of the operator All keypad controls must be easily accessible U bracket mounting 1 Place the bracket in the desired mounting location Ensure that the chosen location has enough height to accommodate...

Страница 16: ...quirements The power supply must be installed in an area that offers sufficient cooling and that is not subject to temperatures is excess of 55 C Ideally the area should be actively ventilated to ensu...

Страница 17: ...in place The power supply unit is supplied with different fasteners to suit most mounting materials Self tapping wood screws with washers and nuts x4 for wood fiberglass or soft plastics and machine...

Страница 18: ...1 Heater element 2 Connector female for temperature sensor 3 In line fuse holder 10 A SB fuse 4 External waterproof socket 5 Thermo conductive gel 6 Temperature sensor 7 2 x hex pan screws M4 8 2 x he...

Страница 19: ...inside Secure the plug body to the transceiver housing with existing fasteners Inside the up mast transceiver identify the temperature sensor and heater element mounting locations by referring to the...

Страница 20: ...le Upper element is directly inserted into this hole 5 Upper heater element retaining screw hole Pan head screw is inserted here to retain the element 6 PCB mounted cable clip Pass a heater loom throu...

Страница 21: ...Install the SI80 The SI80 is delivered with an Installation Guide SI80_IG_988 10475 00n See the guide for installation instructions Hardware mounting R3016 12U 6X Installation manual 21...

Страница 22: ...rce to finish pulling through the remaining cable consider rerouting cable via an alternative route otherwise cable conductors may get broken the cable sheath insulation may be damaged or the same dam...

Страница 23: ...fitting apply a suitable anti corrosive coating to the assembly Note Radar mast should be a good conductor i e metal and be bonded to rest of ships ground If not earth cable should be run to nearest g...

Страница 24: ...pplies is used to drive the transceiver the other powers the heater To access the electrical terminals on the power supply remove the front cover by undoing the six Philips screws on the front of the...

Страница 25: ...y connection status The following table covers the various possible sequences LED Color Pattern Meaning STATUS Green On constant Output voltage 52 VDC is available to the transceiver POWER Green On co...

Страница 26: ...een the transceiver and controller Failure to do so would make the system non compliant Sensor connection Any sensor connected to the R3016 12U 6X system should meet IMO performance standards and be c...

Страница 27: ...l axis type Connections to a BAM device is mandatory if these devices are available on a vessel Note The gyro compass or heading sensor must have an update rate that is adequate for the ship s rate of...

Страница 28: ...upplied are identical Note The wiring of sensors which are connected to inputs should be recorded for reference as is required when commissioning the system 1 2 6 7 8 3 4 5 1 2 6 7 3 4 5 8 Unit socket...

Страница 29: ...erminator plug not included Refer to Installation Guide supplied with the SI80 for further details including alternative NMEA 2000 connection as well as NMEA 0183 input wiring Note Refer to Accessorie...

Страница 30: ...00 POWER NMEA0183 NMEA0183 1 Voyage Data Recorder with DVI input 2 DVI connectors 3 DVI HDMI adaptor cable Note It is not possible for the user to deactivate video output to the VDR port 30 Wiring R30...

Страница 31: ...exposed unit heater kit fitted 40 C to 55 C according to RMRS rules 2 020101 040 E Vol 2 Environmental Test of Equipment Storage temperature exposed unit 25 C to 70 C According to IEC 60945 ed 4 0 St...

Страница 32: ...ceiver 5 kg antenna R3016 Control unit Kg 4 Power Supply Unit Kg 1 Heater loom connector Trivial Performance RPM 20 or 36 selectable Nominal peak power KW 12 Operating frequency MHz 9410 Pulse length...

Страница 33: ...Deg 0 1 Relative Motion RM Head Up Course Up and North Up True Motion TM Course Up and North Up Off centering Up to 75 of range scale in use Cursor Polar and Geographical coordinates continuously dis...

Страница 34: ...ation Relative Geographic Map storage By name Built In non volatile memory used SD Card transfer available Map adjustments Translation and rotation allowed Parallel Index Four independent parallel ind...

Страница 35: ...hless controller assembly 000 10681 001 Bearing reader PCB 000 10671 001 SRT power PCB 000 10672 001 SRT MOS PCB 000 10674 001 SRT control PCB 000 13253 001 Magnetron 000 12393 001 Serial cable high s...

Страница 36: ...er use 000 12391 001 Ethernet cable 30 m For transceiver or heater use 000 12392 001 Ethernet cable 65 m For transceiver or heater use 000 12427 001 HDMI DVI cable 1 5 m 000 10425 001 SI80 SIMRAD sign...

Страница 37: ...m 7 9 364mm 14 3 524mm 20 6 458mm 18 0 466 mm 18 3 696 mm 27 4 200mm 7 9 146mm 5 7 178mm 7 0 R3000 Power supply unit 213 0 mm 8 39 195 0 mm 7 68 92 5 mm 3 64 196 5 mm 7 74 82 7 mm 3 26 86 2 mm 3 39 PO...

Страница 38: ...19 88 280 mm 11 02 120 mm 4 72 67 mm 2 63 SI80 Signal Interface unit 211 mm 8 29 197 mm 7 77 185 mm 7 27 60 mm 2 36 180 mm 7 08 80 mm 3 15 48 mm 1 88 Antenna rotating diameter 1 8 3 0 m m 7 2 0 5 38...

Страница 39: ...15 m OR 000 12391 001 30 m OR 000 12392 001 65 m PREWIRED 2 x 000 12393 001 2 m 000 12188 001 R3016 RADAR DISPLAY 16 NOTES CABLES PREWIRED OR WITH P N ARE SUPPLIED BY NAVICO 24 VDC FROM SHIPS EMG SUPP...

Страница 40: ...988 10912 001 www navico com commercial...

Отзывы: