manualshive.com logo in svg
background image

Simrad Marine Computer

Installation manual

This manual provides you with the basic information
required to install the Simrad ES70/PI50 Marine Computer.

The Marine Computer is provided as an option for the
Simrad ES70 Echo Sounder System, and the Simrad PI50
Catch Monitoring System.

345266/A

11 March 2010

©

Kongsberg Maritime AS

Содержание MARINE COMPUTER - INSTALLATION REV A

Страница 1: ...you with the basic information required to install the Simrad ES70 PI50 Marine Computer The Marine Computer is provided as an option for the Simrad ES70 Echo Sounder System and the Simrad PI50 Catch...

Страница 2: ...d fairly stated but does not accept liability for any errors or omissions Warning The equipment to which this manual applies must only be used for the purpose for which it was designed Improper use or...

Страница 3: ...mage 14 Windows 7 activation 16 CABLE LAYOUT 18 Rear panel connectors 19 Connector wiring 20 Generic RS 232 Serial line 21 Generic RS 422 Serial line 22 Serial line adapter 23 DRAWING FILE 24 Marine c...

Страница 4: ...erature protection 33 Circuit board handling and packaging 34 Returning a circuit board 35 Electro Static Discharge ESD 35 C BASIC CABLE REQUIREMENTS 37 Cable trays 37 Radio Frequency interference 38...

Страница 5: ...riate vessel certification authority prior to installation of the system Applicable outline dimension and productions drawings are provided in the Drawing file chapter Drawings may also be downloaded...

Страница 6: ...dure This chapter describes how to do the physical installation of the computer and the power supply as well as the display setup Topics Physical installation on page 7 Display setup on page 8 Single...

Страница 7: ...sure that the procedure is followed correctly and in the right order tick off each task after you have done it 1 Locate the most convenient location for the computer In order to allow for future main...

Страница 8: ...es are provided One is used if you wish to use a single display The other is used if you wish to set up the computer with two displays providing the same information Note that the Marine Computer appe...

Страница 9: ...lay you connect during system installation and which video output you use Depending on these choices you may need to set up the display resolution to fit your requirements Two procedures are provided...

Страница 10: ...observe that two display icons are shown 1 2 and 3 If this is not the case click Detect to allow the computer to detect the displays connected to the two video outputs 5 At the top of the Screen Resol...

Страница 11: ...stem Topics Software installation upgrade and removal on page 12 How to install the ES70 PI50 software on page 12 How to obtain the ES70 PI50 license on page 13 How to upgrade the ES70 PI50 software o...

Страница 12: ...omputer Note that minimum hardware and software requirements must be met by the computer 1 Power up the computer 2 Insert the ES70 PI50 CD ROM If your computer is not fitted with a CD or DVD drive cop...

Страница 13: ...ktop to start the application 2 Click the Setup icon under the Main menu to open the Setup sub menu on page 3 Click Installation to open the Installation sub menu On the sub menu click Software Licens...

Страница 14: ...tent on the hard disk will be erased This system restore procedure will take approximately 15 minutes 1 Connect a keyboard and a mouse to the computer 2 Insert the USB memory stick containing the imag...

Страница 15: ...on a small sticker under the computer chassis 14 Make sure that Automatically activate windows when I m on line is selected 15 Click Next 16 Observe that the restore finishes automatically Note The W...

Страница 16: ...icense Terms allow In this way activation helps prevent software counterfeiting You can activate either online or by phone To activate online you ll need an Internet connection Activating by phone req...

Страница 17: ...ated phone system Figure 6 Second option dialog 8 Locate your country on the list then click Next Figure 7 Identify your geographical location 9 Call the phone number provided by the dialog and follow...

Страница 18: ...t the cabling of the entire system refer to the applicable installation manual Topics Rear panel connectors on page 19 Connector wiring on page 20 Generic RS 232 Serial line on page 21 Generic RS 422...

Страница 19: ...nd C Top Audio output use stereo mini jack plug Bottom Microphone input use stereo or mono mini jack plug D DVI output to display E Serial inputs and outputs Use the adapter cable included Note All se...

Страница 20: ...e drawings directly related to the Marine Computer For the remaining cable drawings for the PI50 or ES70 system refer to the applicable installation manual Topics Generic RS 232 Serial line on page 21...

Страница 21: ...the local unit DTE with a 9 pin D connector while the other connects to the peripheral DCE as described in the peripheral unit s documentation Note that this cable does not support all the signals in...

Страница 22: ...ts to the peripheral DCE as described in the peripheral unit s documentation W132 Rev A Generic RS 422 serial line View 9 pin D connector Female 9 pin D pin connector 1 5 9 6 Male 9 pin D pin connecto...

Страница 23: ...ial adapter It allows you to connect four RS 232 serial lines to a common socket on the computer W510 Rev A Serial line adapter To socket on computer Female 9 pin D connectors identified as A through...

Страница 24: ...ine Computer Note The mechanical drawings are for information and guidance only They are not in scale All dimensions are in mm unless otherwise is noted The original installation drawings are availabl...

Страница 25: ...Drawing file Marine computer outline dimensions 80 80 224 264 207 195 86 86 184 268 219 CD010218A Page 1 of 1 Rev A Note All measurements are in mm The drawing is not in scale 345266 A 25...

Страница 26: ...m Do not open the rack or cabinet doors while in rough seas It may swing open suddenly and cause damage or injury For safety reasons during troubleshooting on the equipment with power ON two persons m...

Страница 27: ...ations as for the initial delivery In general all units must be handled with care The carton or case containing the unit must be kept dry at all times and must be sheltered from the weather It must no...

Страница 28: ...ss specific markings permit this 5 The crates must not be placed directly on a dirt floor 6 Do not open the crate for inspection unless special circumstances permit so Special circumstances may be sus...

Страница 29: ...equest a representative of the carrier to be present while the carton is opened so any transportation damage can be identified 3 If any units are damaged prepare an inspection report stating the condi...

Страница 30: ...ocuments that may have been added to the carton during packing and put these to one side Check also for special tools door keys etc Unpacking electronic and electromechanical units Electronic and elec...

Страница 31: ...e agents and isolated from sources of vibration Note Do not break the seal to open a circuit board package before the board is to be used If the board package is returned to the manufacturers with the...

Страница 32: ...ermits wash the unit using a high pressure hose and copious amounts of fresh water Examples are the lower parts of hull units outside the hull or subsea units 2 Ensure that all traces of mud and marin...

Страница 33: ...before packing Re packaging Whenever possible the unit must be stored and transported in its original packing material and or crate In the event that this material is not available proceed as follows...

Страница 34: ...and the bag will be sealed See also section Electro Static Discharge ESD on page 35 Unpacking and handling circuit boards To unpack a circuit board Wherever possible prepare a suitable workbench It mu...

Страница 35: ...serviceable circuit boards Electro Static Discharge ESD What is ESD Electro Static Discharge ESD is the transfer of an electrostatic charge between two bodies at different electrostatic levels caused...

Страница 36: ...e conductive service mat during installation maintenance etc 4 If for any reason it is necessary to move the circuit board from the conductive service mat it must be placed in an approved antistatic t...

Страница 37: ...itable shields must be provided where cables are installed in the vicinity of heat sources Unless it is absolutely unavoidable cables should not be installed across the vessel s expansion joints If th...

Страница 38: ...f entry and exit Physical protection Cables exposed to the risk of physical damage must be enclosed in a steel conduit or protected by a metal casing unless the cable s covering e g armour or sheath i...

Страница 39: ...nnected in series via a junction box or terminal block the screens of both cables must be connected together but not grounded Cable terminations Care must be taken to ensure that the correct terminati...

Страница 40: ...ISBN 978 82 8066 123 4 2010 Kongsberg Maritime AS...

Отзывы: