S661

Rate Counter

Operation Manual

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for S661

Page 1: ...S661 Rate Counter Operation Manual www com information itm com 1 800 561 8187...

Page 2: ...repaired or altered outside the SIMPSON ELECTRIC COMPANY factory or authorized service centers nor which has been subject to misuse negligence or accident incorrect wiring by others or installation o...

Page 3: ...6 3 2 Display Error Messages 17 3 3 What the Keys Do in Display Mode 18 3 4 What the Keys Do in the Programming Mode 18 3 5 Special Start Up Modes 21 4 Counter Operations and Parameters 21 4 1 Passwor...

Page 4: ...ctions are easily programmed from the front panel following easy to use word prompts Front panel reset disable and pass word lockout protection features guard against unauthorized or accidental change...

Page 5: ...es field configuring slide in modules The modules slide easily into the rear of the counter Figure 1 displays the functional assignments for each module position 1 2 5 4 Input Excitation Power Supply...

Page 6: ...iption See Section 1 Input Standard Input Module 2 4 1 Input Quadrature Input Module 2 5 2 Ext 45064 12 VDC Excitation Module 2 6 4 Power 120 VAC Power Module 2 3 4 Power 240 VAC Power Module 2 3 5 Ou...

Page 7: ...cutout remove the clips from the side of the counter Slide the counter through your panel cutout then slide the mounting clips back on Press evenly to ensure a proper fit Figure 2 Counter and Panel C...

Page 8: ...nfigure switches or jumpers for proper operation Table 1 can be used to identify modules and their associated detail paragraph 3 Install module by carefully aligning module edges with slots in case an...

Page 9: ...tate device Actuation is immediate upon an active Low for at least 2 5ms to this terminal The reset circuit is independent of the power circuit Figure 6 Standard Input Module Coupez l alimentation ava...

Page 10: ...the type of sensor that is being used If a PNP sinking sensor is be ing used set the input board for sinking also switched 3 and 6 OFF If channel B is not used default settings for switch positions 1...

Page 11: ...Source internal pull down enabled 4 A Channel Bias OFF Hi VLT 5 0 V VUT 7 0V 10 ON Low VLT 1 6 V VUT 3 6V 10 5 A Channel Frequency OFF Hi low pass filter disabled ON Lo low pass filter enabled 6 A Ch...

Page 12: ...to the Standard Input module with the added capability to selectively invert A B and User input signals The Input module also provides for a User input signal On the S661 this input serves as a Dis p...

Page 13: ...T COMMON COMMON INPUT Secondary Input or Quadrature B Denotes module position 1 at rear of counter Display Hold Freezes Displayed value Primary Input or Quadrature A 1 2 3 4 5 6 7 8 9 10 B Bias Off Hi...

Page 14: ...ource internal pull down enabled 4 A Channel Bias OFF Hi VLT 5 0 V VUT 7 0V 10 ON Low VLT 1 6 V VUT 3 6V 10 5 A Channel Frequency OFF Hi low pass filter disabled ON Lo low pass filter enabled 6 A Chan...

Page 15: ...the excitation supply to the logic input common may be required Examples of this appear in figures 8 8a 11 and 12 Figure 12 Wiring Encoder with External Supply A INPUT USER INPUT B INPUT COMMON COMMON...

Page 16: ...activate circuit loads of up to 5 amps at 250 VAC A Form C configuration allows use of normally open NO and normally closed NC circuit action Only the output 1 channel is implemented in the single rel...

Page 17: ...out 6 digit 0 56 high red LED display 2 Output Status Indicators 1 and 2 Units Window for supplied label or legend 4 Button keypad with tactile response Output Status Indicators 4 Button Keypad Numeri...

Page 18: ...lay value Reset Counter E1 Outputs deactivate count stops Raw Count Overflow The number of count pulses has exceeded the counter s maximum internal value 2 147 483 648 or 2 147 483 648 Reset Counter E...

Page 19: ...ior Press and hold for four seconds to exit the programming mode S or T The up and down keys navigate through the available menu functions The menu wraps around when the bottom or top of the menu is r...

Page 20: ...ntry of the prop er password is required to access the remainder of the menu Setup Menu At the first level of the menu the arrow keys navigate up or down through the available Menu selections Function...

Page 21: ...T The up and down keys scroll through the available choices in the Choice list Saves the current choice as new parameter setting and steps to next parameter or category Key Keypad behavior Selects th...

Page 22: ...ace of the counter Apply power while holding keys 4 Counter Operations and Parameters This section details the programming options of the S661 presuming all defaults are in place If you are already fa...

Page 23: ...ay shows 000 Use the arrow keys to change the flashing digit to the desired number c Press to advance to the next digit Press to accept the password to counter memory and press it again to advance to...

Page 24: ...eturn to chpass Press to change password or press the key to continue to the Input Setup menu category 4 2 A B Channel Options Input Setup The next category in the Programming Mode is the Input Setup...

Page 25: ...to Down pulses at the A input will increment count Table 7 Count Behavior with B Channel Set as Direction Control When A channel has been set to either Quadrature or Reverse Quadrature settings the B...

Page 26: ...1 0000 press 2 Use the arrow keys to select the correct value for the flashing digit press to advance to the next digit 3 When the correct value is displayed press to accept and proceed to next pa ram...

Page 27: ...sec Hz sec Mode User entered Multiplier 5000 Scale User entered additive value 100 00 Offset Decimal Position 0000 00 DP Table 9 Rate Example The input frequency can be linearly scaled using the Scal...

Page 28: ...i s r e fe r r e d t o a s a n o n retriggereable timer A RESET will cancel the timed output Latch Output The latch mode activates an output when a trigger or set point is reached The output will act...

Page 29: ...e entered and accepted into counter memory counter will proceed to next menu category Set Point Setup 4 5 Set Point Parameters Set Point Setup The S661 has four set point parameters and an Offset Valu...

Page 30: ...access the Miscellaneous Controls enter the Programming Mode and press until the reset setup menu category is reached 2 Press to continue to the Parameter Name rstbtn The display will flash be tween...

Page 31: ...antaneous 0 02 of reading Frequency vs temperature 0 0001 of reading per C Frequency vs time aging 0 002 of reading per year Display Digits 6 digit 7 segment with leading zero blanking Display Decimal...

Page 32: ...N Case Depth 3 24 82mm Weight 9 0 oz 255 1g Standard input module Input Channels A B and User Count edge High to low transition A and B channels Input Sources Switch contact CMOS or TTL logics PNP or...

Page 33: ...9 0 16 VDC 10 Sourcing 5 1K 5 Res Pull down to common Input Thresholds A B channels Low Bias mode VLT 1 6V 10 VUT 3 6V 10 High Bias mode VLT 5 0V 10 VUT 7 0V 10 User Channel VLT 0 9V min VUT 3 15V max...

Page 34: ...ameter Tip Photocopy these pages to mark settings on Menu Category Parameter Name Choices Format Description Tech Note PASS 000 Password Entry and Verification 4 1 ACCESS dEniEd Password Fail Appears...

Page 35: ...de Select count mode for B channel Note If A channel set to Quad or Rquad this item is not accessible 4 2 rAtE SEtuP MmodE MmSEC SEC Mmin Hr Rate Mode Defines the prescaling and sampling interval for...

Page 36: ...Set Point parameters 4 3 oFFSEt 000000 Offset Set Display Value 2 Rate scaling offset Values 99999 to 999999 A decimal point will appear according to the user programmedDP position 4 3 oPut 1 SEtuP M...

Page 37: ...1 Output 1 delay time Appears only if Output 1 mode set to timed 4 4 oPut 2 SEtuP MmodE2 diSAbL timMEd LAtCH bound Output 2 Mode Set the mode of operation for Output 2 Can be disabled timed latched o...

Page 38: ...e set to timed 4 4 SEtPnt SEtuP SP1 000010 SP1 Set point 1 Low Values 99999 to 999999 Decimal point will appear according to the current DP setting 4 5 SP2 000020 SP2 Set point 1 High Values 99999 to...

Page 39: ...according to the current DP setting 4 5 SP4 000040 SP4 Set point 2 High Values 99999 to 999999 Decimal point will appear according to the current DP setting 4 5 rESEt SEtuP rStbtn EnAbLE diSAbL Reset...