background image

 

 

 
 
 
 

 

 

 

 
 
 
 
 
 
 
 
 

Technical Manual & 

Replacement Parts List 

 

Specifications Subject to Change Without Notice. 

Refrigerator 

1600 Xenium Lane North, Minneapolis, MN 
55441-3787 
Phone (763) 923-2441 

MODEL:  SKR27A-ED 115V 

FORM NO. 45287-SK   REV F  08/2021 

Summary of Contents for SKR27A-ED 115V

Page 1: ...l Manual Replacement Parts List Specifications Subject to Change Without Notice Refrigerator 1600 Xenium Lane North Minneapolis MN 55441 3787 Phone 763 923 2441 MODEL SKR27A ED 115V FORM NO 45287 SK REV F 08 2021 ...

Page 2: ...ent or similarly qualified persons in order to avoid a hazard This refrigeration unit is not intended to be used at altitudes higher than 2000 meters Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance Do not exceed the maximum load capacity of 75 pounds per drawer If the unit has recently been transported on its side or placed horizontally then ple...

Page 3: ...ey are installed tightly to prevent future thread wear Return the unit to the upright position Allow at least two hours of off time before connecting to a power source Drawers To remove the Drawers for cleaning simply open them fully push the Stop Levers out of the way on the Cabinet Drawer Tracks and remove the Drawer To reinstall the Drawer line up the drawer tracks on the cabinet and the Drawer...

Page 4: ...s evaporated into the room air It is important that the unit be installed level to allow proper drainage of the defrost water MAINTENANCE Preventative maintenance is minimal although these few steps are very important to continued operation and maximizing the life of the appliance Cabinet Surfaces The cabinet interior is aluminum and the exterior is stainless steel These surfaces should be cleaned...

Page 5: ...4 ...

Page 6: ...5 ...

Page 7: ... 38353 14 FILTER CONDENSER OPTIONAL 31221 15 CASTER KIT 3 10314 63 16 KIT COMPRESSOR W ELECTRICALS 115V 60HZ 11700 12 17 KIT ELECTRICALS 115V RELAY OVERLOAD 11701 12 18 GROMMET COMPRESSOR MOUNT 20481 19 WASHER COMPRESSOR MOUNT 22401 20 HAIRPIN CLIP COMPRESSOR MOUNT 98106 21 DRIER 22677 22 ELECTRONIC TEMPERATURE CONTROL 115V 46662 23 CONDENSATE PAN ASSEMBLY 38262 24 CONDENSER FAN MOTOR 115V 39577 2...

Page 8: ...7 ...

Page 9: ...mpare the multimeter s reading to Table 1 Analyze Results If the resistance and temperature are similar then the thermistor is working properly and does not need to be replaced If the resistance and temperature are not similar or the resistance s value is not on Table 1 then the thermistor is not working properly and needs to be replaced If the resistance reads over limit then the thermistor is no...

Page 10: ...xterior shell Condensing coils must be cleaned at regular intervals Failure to do so can cause compressor malfunction and will void warranty Although cleaning requirements vary in accordance with operation of various products Silver King advocates a minimum monthly cleaning The Equipment warranty does not include freight handling installation labor following the 1 year labor warranty period or oth...

Page 11: ...e responsibility of the equipment purchaser ADDITIONAL WARRANTY GUIDELINES A factory issued Service Authorization Number must be obtained prior to work being performed under the 1 one year labor warranty Contact your supplier or Silver King Claims submitted without a Service Authorization Number will be paid at Silver King s discretion The labor warranty includes standard straight time labor charg...

Page 12: ... refrigeration units manufactured after September 1 2015 shall remain the property of Silver King and are not transferred IN NO EVENT SHALL SILVER KING BE LIABLE FOR CONSEQUENTIAL SPECIAL OR PUNITIVE DAMAGES THE REMEDIES OF PURCHASER SET FORTH HEREIN ARE EXCLUSIVE AND THE TOTAL LIABILITY OF SILVER KING WHETHER BASED ON CONTRACT WARRANTY NEGLIGENCE INDEMNIFICATION STRICT LIABILITY TORT OR OTHERWISE...

Reviews: