background image

Pharmaceutical Refrigerator
Operation Manual

Model: 
EL-RG-9H
EL-RG-1

2

H

EL-RG-1

4

H

EL-RG-16H
EL-R-16H
EL-RG-23H
EL-RG-31H
EL-RG-33H
EL-R-33H 

Checker:  

AEGIS SCIENTIFIC

1 Ivybrook Blvd, Unit 145R, Ivyland, PA 18974, USA 

Tel: 1-800-796-2344 / Fax: 732 879 0248

 

Website: 

www.aegisfridge.com

Read the Operation Manual carefully before using your appliance.
Keep the Operation Manual in a safe place.
Appearance , color and layout of the door may vary.
Translation of the original instruction.
This product is only applicable for storage of pharmaceutical products or drugs. Not
 applicable for storage of blood or blood products including biological products, for 
example biological vaccine, agents for in vitro diagnosis and etc.

Certificate of Quality

Summary of Contents for EL-R-16H

Page 1: ...isfridge com Read the Operation Manual carefully before using your appliance Keep the Operation Manual in a safe place Appearance color and layout of the door may vary Translation of the original instruction This product is only applicable for storage of pharmaceutical products or drugs Not applicable for storage of blood or blood products including biological products for example biological vacci...

Page 2: ...stic bag Key Shelves Label strip Drain hole cap Fixed card Model Operation Manual EL RG 14H EL RG 9H EL RG 12H 1 2 4 4 1 16 1 1 2 5 5 1 20 1 1 2 5 5 1 1 Brackets for rear wall distance 2 2 EL RG 16H 1 2 7 7 1 1 2 Pad lock Handle Kits Power cord Kits 1 0 1 0 1 1 2 EL R 16H 1 2 7 7 1 1 2 1 1 1 Plastic bag Key Shelves Model Operation Manual EL RG 31H EL RG 23H 1 2 6 1 24 1 1 4 12 12 48 1 0 1 EL RG 33...

Page 3: ...xcept EL RG 9H 14H Automatic removal of condensate water Note Technical information might be somewhat different on your refrigerator than published due to continuous improvement The product is applicable to pharmacies pharmaceutical factories quarantine stations health centers and hospitals used to store pharmaceuticals medicine and other related products which need a storage environment of 2 8 1 ...

Page 4: ...igh low temperature alarm sensor error alarm power failure alarm low battery power alarm door ajar alarm DC 12V rechargeable battery Name Model 48 h when the battery is fully charged Anti shock Safety Classification I Power connection type Y Climate Type 4 Foaming Agent CP IP Noise Level Lp 45dB A 770W 4 5A 115V 60Hz 850W 11A 1130 755 1980 1030 590 1425 Note Climate Type 4 means the temperature is...

Page 5: ...the unit over to cause personal injury Only connect the refrigerator unit with a dedicated power outlet specified by the nameplate of the unit This is to avoid fire or electric shock If the supply voltage is lower than 198 V or higher than 242 V an automatic voltage regulator of at least 4 000 W should be installed with the refrigerator Safety Precautions Ignoring this warning may result in death ...

Page 6: ...upervision is unavailable for a long time make sure children are not near the unit and the door cannot be completely closed and locked End of life disposal of a unit should only be performed by a professional Remove the door to avoid accidents such as suffocation Do not store flammable explosive or volatile articles inside the refrigerator and do not use flammable sprays nearby This is to avoid an...

Page 7: ...built in structure clear of obstruction If your cabinet is to be discard you must remove the door and leave the shelves in place This will reduce the posibility of danger to children And the flammable foaming needs to be disposed by professional persons CP IP foaming materials are flammable need professional processing EL RG 16H 665 710 1965 530 555 1380 390L 7 R134a 305g LED 3W 116kg 2 8 220 240V...

Page 8: ...l appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being Meaning of crossed out wheeled dustbin The battery in the refrigerator may be low after the refrigerator has been in storage for a long time Turn on the battery charge switch when the unit is powered up to allow the battery to be rech...

Page 9: ...vices may cause electric shock and danger Product Installation Installation environment Ambient temperature 16 to 32 the range of 18 to 25 is optimal Air conditioning system is required as necessary Ambient humidity below 85 RH for EL RG 9H 14H the humidity should be less than 70 RH Avoid excessive dust Avoid mechanical vibration The refrigerator shall operate at an altitude lower than 2000m Input...

Page 10: ...uld be used to remove the unit off the pallet Forklift should reach the bottom of the wood pallet for lifting The unit should not be tilted at an angle of more than 45 degree Circuit diagram EL RG 31H CN2 Compressor Defrosting heating strip CN2 CN1 CN3 CN11 BT1 BAT BAT Main control panel CN5 Display panel CN2 CN3 Sensor Alarm Defrosting Control Lower temperature Upper temperature VCC GND Heating s...

Page 11: ...distance 7 Install handle EL R G 16H 23H 33H Pic 1 Pic 2 9 Circuit Diagram EL RG 23H CN2 Cooling fan Compressor Defrosting heating strip CN2 CN1 CN3 CN11 BT1 BAT BAT Main control panel CN5 Internal fan Display panel CN2 CN3 Sensor Alarm Defrosting Control Lower temperature Upper temperature VCC GND Heating strip at the cabinet outlet CN1 t Door heating strip Door heating transformer CN1 J5 L N USB...

Page 12: ...minal H of the mechanical thermostat can be exchanged CN6 NO COM NC NO COM NC Remote alarm port Compressor Note The content in the frame with dotted lines are applicable for products with the printer LED lamp bank Printer door Door switch Note EL R 16H has no Door heating strip Door heating transformer and mechanical thermostat 8 Back Bracket EL R G 9H 12H 14H 16H Pic 5 9 Power line bracket instal...

Page 13: ... stable condition When the temperature becomes stable inspect the actual temperature to make sure it matches the set point Turn on the light switch and ensure the light inside the freezer operates properly When the refrigerator passes all the functional inspections load in products in batches Initial Power on 11 Circuit Diagram Circuit diagram EL RG 9H 14H CN2 CN2 CN1 CN6 NO COM NC CN3 CN11 BT1 BA...

Page 14: ...ion after Power Outage Overcurrent Protection Circuit Breaker Instruction Installing Location Install the Breaker on the back of cabinet There is a special warning label Operating Principle It s a device that trips like a switch and opens the circuit when over loaded This will protect the freezer s entire circuit To restart the unit the user needs to press down the switch and the unit will power o...

Page 15: ...replacement b Battery removal 1 Unplug the unit from the power outlet 2 Remove the screws on the cover with a screw driver 3 Unplug the battery s connecting plugs 4 Remove the battery s holding clip and remove the battery 5 Recycle or dispose of the used battery as required When replacing the battery make sure that brown wire is connected to the battery s positive pole and blue wire to the battery...

Page 16: ...erator If necessary use light detergent water to wipe off the unit if necessary Then use a dry cloth to wipe it again Do not dump water directly onto the interior of the unit to avoid damage to electrical systems Compressor and other mechanical parts are hermetically sealed They don t need lubrication 2 EL R G 12H 16H 23H 31H 33H is equipped with a LED lamp To replace the lamp please contact the s...

Page 17: ...e NO or NC if needed EL R G 12H 14H 16H 31H 33H has remote alarm terminals When the system is in the alarm mode you can press the Silence on the display panel to cancel the alarm The remote alarm will not be stopped If the alarm condition still exists the buzzer will return to the alarm mode again automatically 20 minutes later EL RG 9H 14H series does not have the remote alarm function Remote Ala...

Page 18: ...zing Alarm High temperature Low temperature Outage Door ajar Sensor abnormities Alarm light flashes Alarm light flashes Temperature Display area displays inside temperature for 60s and stop displaying for 60s then repeat Alarm light flashes after 10 min delay Impulsive sound alarm Impulsive sound alarm within 48h outage Give impulsive sound alarm after 10 min delay If upper temperature sensor or l...

Page 19: ...s all changes of parameters will not become effective The previous settings are restored 2 If the unit is powered off before the parameters are saved the control parameters in the RAM will be lost The unit will retain the previous set up once the power recovers 3 Humidity measuring range 20 90 RH humidity measurement accuracy 5 RH 40 RH 80 RH 8 RH Others ...

Page 20: ...not need to set press the Cal for 5s to save it and exit Please checking the time before use if the time is not right follow the upper method to adjust the time Wait for one minute to download the datas after adjustment EL RG 33H Control panel Handle Light switch Shelf Glass door Door lock Leveling leg Caster Anti condensation controller EL RG 31H Anti condensation controller intelligently operate...

Page 21: ...mes out press the Cal to save it After that the display area of inner temperature shows 5P stably Press the Cal and the display area of inner temperature blinks the minute Press the Sensor decrease or Cal Cancel increase to choose the minute It displays 00 to 59 recurrently When the current local minute comes out press the Cal to save it After that the display area of inner temperature USB Functio...

Page 22: ...for at least 2 additional hours after it reaches stable condition 2 Place a standard thermocouple in the temperature solution bottle filled with 100 ml 10 glycerol solution Place the sensor of the temperature recorder into the sensor bottle as well 3 Place the sensor bottle in the refrigerator for at least 4 hours Compare the thermocouple reading and the recorder reading If there is a discrepancy ...

Page 23: ...ding pen to make the nib contact with the recording paper Note Do not damage the nib and crossbeam If it is difficult to be adjusted use a screwdriver to dismount the crossbeam After bending the crossbeam with a little strength install back the crossbeam and repeat the above operations 6 Ensure the accuracy of the recorder Calibrate the preciseness of the recording pen after each replacement of pa...

Page 24: ...urface The equipment will start the forced defrost cycle Once the frost is thawed the refrigerator will resume normal operation Chart Adjustment Buttons 9 volt battery Chart Adjustment Buttons Imprinting Stylus Date Reference Mark Center Nut and Chain Chart Paper Temperature Recorder optional Chamber temperature recorder with 6 inch standard panel is optional for EL RG 23H to record chamber temper...

Reviews: