Siemens S7-200PLC Ethernet Adapter 

 ES-ETH-PPI 

 

USER MANUAL

 

 

 

 

 

 

 

 

All rights reserved 

 

 

 

 

Summary of Contents for ES-ETH-PPI

Page 1: ...Siemens S7 200PLC Ethernet Adapter ES ETH PPI USER MANUAL All rights reserved ...

Page 2: ... S7 200PLC 18 3 The communication between the PC and multiple S7 200PLCs 19 4 The intercommunication among the multiple S7 200PLCs 25 6 Remote communication in the internet 26 1 STEP7 Micro WIN software setting 27 2 Remote communication between PC and S7 200PLC 30 3 Remote communication between two PCS S7 200PLCs 35 7 Remote wireless communication in the 3G wireless internet 39 1 STEP7 Micro WIN s...

Page 3: ... manual we won t assume any liability of property damage or personal injury due to your improper use We have the right to revise this maual at any time according to the needs of technology development and it won t be noticed before the revising Copyright Statement Any people and institutions copy all or part will assume the corresponding legal responsibility without prior written consent Version I...

Page 4: ...ial situations Especially the isolated power supply port and each signal pin has anti static protection and surge protection which can solve the communication port easily damaged problem for Siemens S7 200PLC Notice When ES ETH PPI is used to communicate between PC and S7 200 PLC you need to set the local connection as Modem connection in the STEP7 Micro WIN software When it s used to communicate ...

Page 5: ...UDP unicast Built in Flash memory can save the setted parameters Support Windows 95 98 ME NT 2000 XP 2003 XP Vista Win7 RJ45 port 1500VDC electromagnetic isolated RS485 interface 1000VDC electromagnetic isolated power supply 1000VDC electromagnetic isolated Interface protection power supply port has the reverse polarity protection and over current protection RS485 interface has the 500W anti light...

Page 6: ...dard network cable not crossover cable whether you connect the switch or directly connect the PC The network status LED indicator on the RJ45 socket LINK LED LEFT GREEN ACT LED RIGHT YELLOW State description State description Light on Network cable is connected correctly work properly Flash Sending and receiving data through the RJ45 port Flash Network cable is not plugged in no available network ...

Page 7: ...password you can restore to the factory default parameters and then reset the parameters RS485 Interface RS485 interface is the DB9M pin plug which meets the Siemens S7 200 Series PLC PPI interface technical specifications the signal array match S7 200 series PLC PPI interface and has a 0 5 meter cable you just simply plug the DB9M directly into the S7 200PLC PPI interface outlet The signal array ...

Page 8: ...nal polarity reversal Serial port is sending the date Fault or no communication 3 Inner Diagram 4 ES ETH PPI parameters setting ES ETH PPI needs to be configured the parameters to work correctly the configuration parameters including the network parameters communication protocols connection serial port parameters it can be very flexible to satisfy your application Configuration parameters are stor...

Page 9: ...dafault IP 192 168 0 250 Username admin Password admin You need to check your computer s IP address and gateway address and confirm your computer is in the normal Internet access in the next setting you need to set the gateway of ES ETH PPI as same as the gateway of computer and router that is to say the ES ETH PPI and computer are in the same subnet all equipments in this subnet and routers have ...

Page 10: ...__ 10 Copy the OEM Device Manager_SPCNML rar file on the CD to your hard disk and extract it to the current folder do not modify the folder name OEM Device Manager_SPCNML which store the setting software Double click the following icon in the OEM Device Manager_SPCNML folder to run setting software ...

Page 11: ..._________________________________ 11 Change language to English Ctrl L and then press E or select the menu as the picture up Click the Search button in the upper left corner and then search out all ES ETH PPI connected to the router after a few seconds as shown below ...

Page 12: ...e modified parameters parameters not saved at this time after you modify the parameters in every interface then click the Apply Settings Restart to save parameters and restart the ES ETH PPI to work with the new parameters and then exit the setting software As shown below About the parameters configuration details please read the Device Manager Parameters setting software manual After you configur...

Page 13: ...rity stop bit 1 referred to as 8E1 This is the PLC default mode Siemens S7 200PLC 10 bit RS485 interface communication parameters data bits 8 bits parity NONE no parity stop bit 1 referred to as 8N1 This mode is used in the Internet communication S7 200PLC baud rate 9 6Kbps or 19 2Kbps ES ETH PPI does not support 187 5Kbps baud rate Firstly please use such as PC PPI programming cable to check the ...

Page 14: ...cation is among multiple Ethernet devices which are connected to a same router The ES ETH PPI communication in the LAN needs to ensure that PC ES ETH PPI and routers have the same gateway The gateway 192 168 1 1 the computer IP address 192 168 1 108 ES ETH PPI IP address 192 168 1 250 in the following examples 1 STEP7 Micro WIN software setting Select RS485 communication mode switch on the ES ETH ...

Page 15: ..._________________________________________________________________________________ 15 connection mode Click the Communication button to enter the communication settings double click connection to set the modem parameters ...

Page 16: ...___________________________________________________________________________________________________ 16 Select the modem connection and configure serial port parameters choose even parity 11 bit mode ...

Page 17: ..._________________________ 17 Click Connect button to establish the connection Double click the Refresh to search the PLC and then you can find the all PLCs connected to the network then select the PLC which you want to operate in the next step you can upload download the data ...

Page 18: ..._____________________________ 18 2 The communication between the PC and a S7 200PLC Set the ES ETH PPI network parameters the gateway of ES ETH PPI PC and router must be same the DNS server needn t to be setted because you don t use the dynamic domain name on the Internet ...

Page 19: ...______________________________________________________ 19 The setting of ES ETH PPI serial port parameters is omitted here you can see the previous description Set ES ETH PPI working mode as TCP Server port No 27011 waiting for clients to connect ...

Page 20: ...ual serial port Add a virtual serial port the remote server IP address ES ETH PPI IP address remote server monitoring port ES ETH PPI port Click OK and exit the software and re run VCOMM the client side VCOMM will take the initiative to connect the server side with IP address 192 168 1 250 port number 27011 it will create a new serial port COM3 after establishing the connection and it will appear ...

Page 21: ...icate with a PC via Ethernet you need to set every ES ETH PPI connected with PLC as TCP Client set the PC as the TCP Server let every client ES ETH PPI takes initiative to connect the server PC When VCOMM Virtual Serial Port Software work as TCP Server it allows unlimited number of connected clients Set the ES ETH PPI network parameters the gateway of ES ETH PPI PC and router must be same the DNS ...

Page 22: ...o the different addresses The setting of each ES ETH PPI serial port parameters are the same with PLC and they are omitted here you can see the previous description Set each ES ETH PPI as the TCP Client the remote host IP PC IP address host port VCOMM software port number That is to say each ES ETH PPI have to connect to server side VCOMM with IP 192 168 1 108 port 8000 ...

Page 23: ...rt Add a new virtual serial port the monitoring IP address PC IP address client mode device try to connect the port VCOMM software port this is 8000 Click OK and exit the software and re run VCOMM server side VCOMM will accept as many as client side ES ETH PPI connections and it s unlimited A new serial port COM3 will appear on the PC after the connection is established And this serial port will a...

Page 24: ...___________________________________________________________________________________________________ 24 You can find the all PLCs via communication search of STEP7 Micro WIN as shown below ...

Page 25: ...t support PPI advanced PPI Multi master PPI communication protocol and MPI and profibus protocol About the setting of Multicast address here is a brief introduction In fact Multicast address is the Class D IP address that s to say the first byte of the upper 4 bits of the IP address is the 1110 so the multicast range 11100000 00000000 00000000 00000000 11101111 11111111 11111111 11111111 224 0 0 0...

Page 26: ...ch ES ETH PPI as a different IP address every ES ETH PPI serial port parameters are the same as PLC serial port parameters 6 Remote communication in the internet ES ETH PPI can achieve the worldwide remote communication through the Internet it will use the external network IP address of the router the router external network address is different when the router is started every time because the ro...

Page 27: ...r IP address as the local DNS server IP addresses then you can use the dynamic domain name to visit the internet In the following example use our free dynamic domain name kollew changeip net use the PC in Server side and run the dynamic domain name client software you can also use a router with the function of dynamic domain name 1 STEP7 Micro WIN software setting Select RS485 communication mode s...

Page 28: ...___________________________________________ 28 Click the Communication button to enter the communication settings double click connection to set the modem parameters Select the Radio RF modem and configure serial port parameters choose no parity 10 bit mode ...

Page 29: ..._________________________ 29 Click Connect button to establish the connection Double click the Refresh to search the PLC and then you can find the all PLCs connected to the network then select the PLC which you want to operate in the next step you can upload download the data ...

Page 30: ...___________________________________________________________________________________________________ 30 2 Remote communication between PC and S7 200PLC ...

Page 31: ...rameters the gateway must be the same as the router connected with the ES ETH PPI here you still need to properly set the IP address of DNS different cities have different DNS Server IP you can use all but usually choose the local DNS you can search these addresses from Internet also can find them from the router which you are using Set the serial port parameters of ES ETH PPI please note that you...

Page 32: ... when the client ES ETH PPI visit and access the router s external network IP address this address is automatically resolved by the domain name you no longer cares about its change router will automatically transfer this visiting to the VCOMM virtual serial port software on the PC with IP address 192 168 1 108 port 8000 which is connected to the router After setting click Restart Router button or ...

Page 33: ...rt software on the PC set the simulated virtual serial port on the PC Select VCOMM as Server mode accept client connections Choose to use the device detector to create a virtual serial port Add a new virtual serial port the monitoring IP address PC IP address client mode device try to connect the port VCOMM software port this is 8000 ...

Page 34: ...e ES ETH PPI as the server set VCOMM as the client but the router connected with ES ETH PPI need to have the DNS function or you can use a PC connected to the router which is connected with the ES ETH PPI to run the peanut shell software to resolve the domain name When the VCOMM software work as the client you also could input the domain name directly in the remote server IP address support DNS re...

Page 35: ...at when the two PLCs are communicated via ES ETH PPI you only can use the RS485 free port communication protocol not support PPI advanced PPI multi master PPI protocol MPI and PROFIBUS protocol Use two pcs ES ETH PPI to connect with two pcs S7 200PLC the switch of communication mode select 11 or 10 bit it depends on the free port RS485 protocol communication parameters which are setted in your PLC...

Page 36: ...the router to work with the new parameters Similarly when two pcs ES ETH PPI go on external network communication you need to set the port simulation on the router connected with the server ES ETH PPI input the IP address of router in the IE browser of PC connected with this router and then enter the virtual server setting interface of the router The server port local port of server ES ETH PPI IP ...

Page 37: ...___________________________________________________________________________________________________ 37 Set the parameters of client ES ETH PPI as below ...

Page 38: ...geip net in the remote host IP box host port is the port number of server ES ETH PPI So that when the client ES ETH PPI connect the domain name of Internet it will automatically connect to the Internet address the external network IP address of the server side router the router automatically transfer to the server module achieve the remote communication from S7 200PLC s serial port to another S7 2...

Page 39: ...age so please read the corresponding product manual When the ES ETH PPI works as the server it is best to use the 3G router with the function of dynamic domain name to connect the ES ETH PPI User should pay an attention on that the current TD SCDMA 3G Mobile and China Unicom s WCDMA 3G network card are using a private network IP address this can only be used as a client can not be accepted as a cl...

Page 40: ...___________________________________________________________________________________________ 40 2 Remote wireless communication between PC and S7 200PLC 3 Remote wireless communication between two PCS S7 200PLCs ...

Page 41: ...f not received confirmation of the host or data error need a certain number of retransmissions In this way it will be additional traffic so slowly than UDP TCP communications including the client Client and server Server the client take the initiative to connect to the server the server can only be a passive client connections once establish the connection the client and server can be duplex data ...

Page 42: ...mmunication it will not increase too much extra traffic it can communicate faster than the TCP to provide real time communication UDP does not need the server and client both parties are on equal communication Our Ethernet to serial communication module using UDP mode including UDP Uni_Cast UDP Multi_Cast UDP unicast UDP Uni_Cast mode Module in the UDP Uni_Cast mode it can be point to point duplex...