LED Followspot 75W

 

 

 

 

 

 

            

ORDERCODE 30628 

 

 

 
 

Highlite International B.V. 

Vestastraat 2 

6468 EX Kerkrade 

The Netherlands 

Phone: +31 45-5667700 

Summary of Contents for 30628

Page 1: ...LED Followspot 75W ORDERCODE 30628 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands Phone 31 45 5667700 ...

Page 2: ...ly on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant showtec info You can get some of the best quality best priced products on the market from Showtec So next time turn to Showtec for more great ligh...

Page 3: ...t Setup 7 Backside Followspot 75W 8 Installation 8 Set Up and Operation 8 Control Modes 8 One LED Followspot Manual Mode 8 Multiple LED Followspots DMX Control 9 Fixture Linking 10 Data Cabling 10 Control Panel 11 Control Mode 11 DMX Addressing 11 Menu Overview 11 DMX Channels 12 3 Channels 12 Maintenance 12 Replacing a Fuse 13 Troubleshooting 13 No Light 13 No Response to DMX 13 Product Specifica...

Page 4: ...s of a higher priority place care in providing for lower operational temperatures This may include climatic environmental and the reduction of overall projection intensity Safety Instructions Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructions of this manual Before your initial start up please make sure that there is no d...

Page 5: ...t Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time Make sure that no side forces can impact on the truss system The cable insert or the female part in the device must never be strained There must always be sufficient cable to the device Otherwise the cable...

Page 6: ... Always let the installation be carried out by an authorized dealer Procedure If the LED Followspot 75W is lowered from the ceiling or high joists professional trussing systems have to be used Use a clamp to mount the LED Followspot 75W with the mounting bracket to the trussing system The LED Followspot 75W must never be fixed swinging freely in the room The installation must always be secured wit...

Page 7: ... description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our announcement that the goods are at their disposal Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of merchandise It is ...

Page 8: ...nually controlled or by DMX 3 Channels Lumen 1600 Lux 1m 25000 Efficiency 21 lm W LED Quantity 1x CW 75W Driver current 19A Iris 2 100 manual Beam Angle 16 22 On Board Display for easy Set Up Options DMX512 Manual 3 DMX Channels Input Voltage 100 240VAC 50 60Hz Power consumption 121W max FO IP Rating IP 20 Housing Die cast Aluminium powder coat finish Connections IEC XLR 3 pin IN and OUT Cooling F...

Page 9: ...plete Followspot Setup 5 6 7 8 9 Fig 2 5 DMX signal connector IN 6 DMX signal connector OUT 7 Stand Pole total setup height 1110 1440 mm 8 Torx bolts for mounting the followspot to the stand 9 Mounting Plate ...

Page 10: ...e cleaning or servicing Damages caused by non observance are not subject to warranty Set Up and Operation Follow the directions below as they pertain to your preferred operation mode Before plugging the unit in always make sure that the power supply matches the product specification voltage Damages caused by non observance are not subject to warranty Control Modes There are 2 modes Manual Mode DMX...

Page 11: ... 3 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 5 Supply electric power Plug electric mains power cords into each unit s IEC socket then plug the other end of the mains power cord into proper electric power supply sockets starting with the first unit Do not supply power before the whole ...

Page 12: ...recommended DMX data link distance 100 meters Maximum recommended number of LED Followspots on a DMX data link 30 fixtures Data Cabling To link fixtures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality s...

Page 13: ... be sure that you don t have any overlapping channels in order to control each LED Followspot correctly If two or more LED Followspots are addressed similarly they will work similarly For address settings please refer to the instructions under Addressing Controlling After having addressed all LED Followspot fixtures you may now start operating these via your lighting controller Note After switchin...

Page 14: ... connections clean Disconnect electric power and then wipe the DMX and audio connections with a damp cloth Make sure connections are thoroughly dry before linking equipment or supplying electric power The operator has to make sure that safety relating and machine technical installations are to be inspected by an expert after every year in the course of an acceptance test The operator has to make s...

Page 15: ... refer servicing to a technician Response Suspect four potential problem areas as factory reset the power supply the LED the fuse 1 Power supply Check that the unit is plugged into an appropriate power supply 2 The LEDs Return the LED Followspot 75W to your Showtec dealer 3 The fuse Replace the fuse See page 13 for replacing the fuse 4 If all of the above appears to be O K plug the unit in again 5...

Page 16: ...t terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is defective and disturbs data transmission on the link Bypass one fixture at a time until normal operation is regained unplug both connectors and connect them directly together Have the defective fixture se...

Page 17: ...600 Lux 1m 25000 Efficiency 21 lm W LED Quantity 1x CW 75W Driver current 19A Iris 2 100 manual Beam Angle 16 22 On Board Display for easy Set Up Options DMX512 Manual 3 DMX Channels Input Voltage 100 240VAC 50 60Hz Power consumption 121W max FO IP Rating IP 20 Housing Die cast Aluminium powder coat finish Connections IEC XLR 3 pin IN and OUT Cooling Forced Cooling Fan Weight LED Followspot 75W 6 ...

Page 18: ......