background image

SL STRIP 10IP 
LED LUMINAIRE 

Summary of Contents for SL STRIP 10IP

Page 1: ...SL STRIP 10IP LED LUMINAIRE ...

Page 2: ...www philips com showline Version as of 17th Sep 2015 SL STRIP 10IP User s Manual 2015 Vari Lite Document Number SL STRIP 10IP LED Luminaires User Manual ...

Page 3: ... Failure to use proper cable can result in damage to equipment or danger to personnel WARNING This equipment is intended for installation in accordance with the National Electric Code and local regulations It is also intended for installation in indoor applications only Before any electrical work is performed disconnect power at the circuit breaker or remove the fuse to avoid shock or damage to th...

Page 4: ...ca market only AC Input cable 1500mm For International market only AC Output cable 1000mm For International market only AC Output cable 1000mm For US Canada and Latin America market only DMX Input cable 1000mm DMX Input cable 1000mm DMX Output cable 1000mm DMX Output cable 1000mm North American Market International Market Installation and User s Manual SL STRIP 10 IP LED Luminaires Note The SL STR...

Page 5: ...anging Application SAFETY CABLE Is sold separately and recommended for all hanging installations and may be required by national and local codes Use the provided safety cable anchor points to attach the safety cable for this luminaire SL STRIP 10IP LED Luminaires are provided with Trunnion Arms The user can tighten the wing screws manually For hanging applications it is recommended and may be requ...

Page 6: ...ower source using an AC input cable For wiring of AC input connector refer to Connecting SL STRIP 10IP LED Luminaires to AC Power Connection from the AC output of another SL STRIP 10IP LED Luminaire When using this method it is very important not to connect any other type of equipment Connecting SL STRIP 10IP LED Luminaires to AC Power WARNING WARNING WARNING Only connect other SL STRIP 10IP LED L...

Page 7: ...tance to flammable materials 0 2m Distance de sécurité minimale aux matériaux inflammables 0 2 m Minimum safety distance from lighted objects 0 5m Distance de sécurité minimale des objets illuminés 0 5m Maximum operating temperature of enclosure surface is 60 C Température de fonctionnement maximale de la surface de l enceinte est de 60 C DO NOT STARE AT THE OPERATING LIGHT SOURCE 警 告 机器在接电前请参阅安装 ...

Page 8: ... 000 100 000 255 000 255 000 255 000 255 To set the initial DMX receiving address To set the DMX Control Mode To set the status of the fixture when there is no DMX input To set the output intensity of the red To set the output intensity of the green To set the output intensity of the blue Can be set as ON or OFF To set the output intensity of the cool white To select a built in program To set the ...

Page 9: ...L STRIP 10IP DMX Mapping RGBW 16 Bit Mode SL STRIP 10IP DMX Mapping RGBW 8 Bit Mode OPERATION MODES 6 Red_1 10 Green_1 10 Blue_1 10 White_1 10 Installation and User s Manual SL STRIP 10 IP LED Luminaires ...

Page 10: ...select and activate the desired chase Press the MODE button to select and activate the DMX menu Set the DMX address DMX Bit DMX Fade and DMX Channel Press the MENU button to select and enter the desired menu The DMX Address Mode is indicated by DMX Addr followed by three digits 001 512 Press the UP and DOWN buttons to change the DMX Address Value Press the MENU button to select and activate the DM...

Page 11: ...e Speed Menu Press the MENU button to select the Chase Speed menu In this menu you can adjust the program chase speed Press the UP and DOWN buttons to adjust the chase speed from 01 to 99 A value of 99 will give you the fastest chase speed approx 1 10th of a second A value of 01 will give you the slowest chase speed once every 30 seconds Press the MENU button to select the Chase Dimmer menu In thi...

Page 12: ...tline and describe all the RDM parameters IDs associated with SL STRIP 10IP Table 1 SL STRIP 10IP RDM Parameter IDs SL STRIP 10IP SL STRIP 10IP 0x1000 Vari Lite Asia 0x0105 RDM PARAMETER IDS 9 82H Installation and User s Manual SL STRIP 10 IP LED Luminaires ...

Page 13: ...Table 1 SL STRIP 10IP RDM Parameter IDs RDM PARAMETER IDS 10 Installation and User s Manual SL STRIP 10 IP LED Luminaires ...

Page 14: ...IDs Manufacturer Defind PIDs range is 0x8000 0xffdf See Table A 3 ANSI E1 20 2010 Get Allowed SET Allowed RDM Parameter Id s TYPE UNIT PREFIX MIN MAX DEFAULT DESCRIPTION Chase program Chase Dimmer DMX Fade on off Manual red Manual green Manual blue Chase Speed Manual white Chase Fade Calibration On off 8A00H 8AA1H 8AB2H 8A0CH 8AB1H 8AA0H 8A92H 8AA2H 8A94H 8A44H U8 U8 U8 U8 U8 U8 U8 U8 U8 U8 1 1 0 ...

Page 15: ... to 104 Degrees F 6 degree native beam angle 15 25 or 11 x 38 degree diffuser lens 2240 lumens 2700 6500K user adjustable 100V to 240V 10 auto ranging 150 Watts max 50 60Hz DMX512 1990 DMX512A RDM On Board Menu Source Beam Angle Light Output Color Temerature Input Voltage Power Consumption Frequency Control Protocols CE C Tick marked and ETL listed IP65 Compliance IP Rating Note Common model speci...

Page 16: ...13 Installation and User s Manual SL STRIP 10 IP LED Luminaires ...

Page 17: ...Industrial Centre No 41 49 Kwai Cheong Road Kwai Chung N T Hong Kong Tel 852 2796 9786 Fax 852 2798 6545 Auckland 19 21 Kawana Street Northcote Auckland 0627 New Zealand Tel 64 9 481 0100 Fax 64 9 481 0101 Europe Rondweg zuid 85 Winterswijk 7012 JD The Netherlands Tel 31 0 543 542516 C 2015 Vari Lite ...