(1.27 - 1.79 mm) .050 - .070 in.

(1.80 - 2.28 mm) .071 - .089 in.

(2.29 - 2.55 mm) .090 - .100 in.

(3.01 - 3.34 mm) .119 - .131 in.

(2.56 - 3.00 mm) .101 - .118 in.

(3.35 - 3.65 mm)  .132 - .143 in.

(3.66 - 4.13 mm)  .144 - .162 in.

(4.14 - 4.71 mm)  .163 - .185 in.

(4.72 - 5.12 mm) .186 - .201 in.

(5.13 - 5.86 mm)  .202 - .230 in.

(5.87 - 6.36 mm)  .231 - .250 in.

(6.37 - 7.00 mm)  .251 - .275 in.

(7.01 - 7.62 mm)  .276 - .300 in.

DIAMETER OF SHIELD

CONNECTOR CAT. 

NO. & CODE

RSK101 or 

RSK5101

RED

RSK201 or 

RSK5201

BLUE

RSK301 or 

RSK5301

YELLOW

RSK401 or 

RSK5401

GREEN

1 OR 2 PIECES 0.25mm2

#24 AWG STR

OR 1 

#22 AWG STR

1 OR 2 PIECES 0.25mm2 

#22 AWG STR 

or 1 PIECE 0.5mm2 

#20 AWG STR

1 OR 2 PIECES 0.25mm2

#22 AWG STR  

1 PIECE 0.5mm2 OR 2 

#20 AWG STR

1 OR 2 PIECES 0.5mm2 

#20 AWG STR 

or 1 PIECE 0.75mm2 

#18 AWG STR

DIE CAT. NO 

(STEEL)

D-301G

D-301J

D-401N

D-401M

D-401L

D-401K

D-301H

D-201F

D-201E

D-201D

D-201C

D-101B

D-101A

GROUND WIRE 

RANGE

ERG740 ERGONOMIC HAND TOOL

OPERATING INSTRUCTIONS
for RSK Series Wrap Around Connectors

IMPORTANT:

 

Read and understand all of the instructions and safety information in this 

manual before operating or servicing this tool.

INTENDED USE:

 Wrap around connectors have been designed to ground the shield of single 

or multiple conductor shielded cables. It Is suggested that the customer evaluate the suitability 
of these connectors and verify their performance for the particular application .

WARNING

KEEP ALL BODY PARTS AWAY FROM DIE NEST 

DURING GAGING OR CRIMPING PROCEDURE.

WARNING

HANDLES ARE NON-INSULATING.

DO NOT CRIMP ON HOT ENERGIZED WIRES.

OPERATING INSTRUCTIONS

MATCHING THE CONNECTOR AND DIE TO THE CABLE 

1

1. Measure the diameter of the cable shield using a calibrated 

measuring tool or the RSK gauge (part number RSK-LEHRE) 
which is in the tool case lid. Rotate the cable in order to 
locate the maximum shield diameter. Exert only light 
pressure on the cable to get an accurate measurement, see 
Figure. 1.
When using the RSK gauge , try to find the appropriate slot 
in the gauge by ensuring that the cable only goes in the top 
of the slot. If the cable goes completely to the bottom of 
the slot, you should try the cable in the smaller adjacent 
slot.
Once you find the appropriate slot, you can read the 
associated RSK connector by the color of the slot and the 
appropriate die by the number marked below the slot.

2. For twisted pair and other non-symmetrical shielded 

cables, measure the dimension of the major axis or the 
largest width of the cable.
When you use the RSK gauge, try to find the appropriate 
slot in the gauge by fitting the largest width of the cable 
into the slot. Similar to step 1, if the cable goes completely 
to the bottom of the slot, try the next smaller adjacent slot.

3. Once the shield diameter is established, refer to Table 1 for 

the appropriate connector and installing die.